YR40/D/RN/FP/S C & S, YR40/D/RN/FP/S Datasheet

SOUNDER, QUAD ALARM, RED

YR40/D/RN/FP/S

Manufacturer Part Number
YR40/D/RN/FP/S
Description
SOUNDER, QUAD ALARM, RED
Manufacturer
C & S
Series
Yodacr
Datasheet

Specifications of YR40/D/RN/FP/S

Transducer Function
Sounder
Frequency Response Min
800Hz
Frequency Response Max
1kHz
Input Current
13mA
Tones
Continuous / Alternate
Sound Level Spl
96dB
Sound Level Distance
1m
Base
RoHS Compliant
90 (3.5”)
All units
Clifford & Snell a division of Signature Industries Ltd part of the Digital Angel Corporation
DIMENSIONS
CONFIGURATOR
Unit Type
Door Holder
Colour
Door Holder
Keyswitch
Mains Adapter
Colour
Keyswitch
Mains Adapter
Supply Voltage
C l i f f o r d & S n e l l
All dimensions quoted are approximate only and subject to change
without notice as are technical features resulting from continual
development and improvement.
Keyswitch
Type (KS)
Yodac Range
Switching
Voltages
230Vac
24Vdc
230Vac
Red Normal
White
White
90 (3.5”)
All units
Mains Adapter
Type (MA)
DH
Keyswitch (KS) Mains Adapter (MA)
48 (1.9”) DH
46 (1.8”) KS
41 (1.6”) MA
Door Holder (DH)
Door Holder
Type (DH)
KS
~ Yodac ~
MA
Controlled document No. D7420-01-02 \\BGRICE\3 Issued\Data Sheets\Keyswitch-Mains Adapter and Door Holder
MAIN FEATURES AND SPECIFICATIONS
Keyswitch type KS
MAIN FEATURES AND SPECIFICATIONS
Door Holder type DH
MAIN FEATURES AND SPECIFICATIONS
Mains Adapter type MA
MOUNTING
These units should be mounted to a reasonably flat surface of
suitable material using internal fixing holes. The recommended
fixing screws are dia 4.5mm max x 20mm long.
When installing the Door Holder unit, ensure the armature is mounted
in line and secured using the screws provided.
DATA APPLICABLE TO ALL UNITS:
Temperature range
Relative humidity
For indoor use only
Red / white flame retardant ABS plastic enclosure
Terminal capacity CSA-2.5 mm
Suitable for security of circuit operation
Flush mounting base available
Switch action
Contact rating non inductive (A) 2 at 240Vac
Number of keys supplied
Approximate weight (g)
An electromagnetic door holder which can be electrically released
in the event of fire
Test / override button
Integral reset
Supplied complete with armature plate
Operating voltage
Voltage tolerance
Current consumption
Holding force
Maximum residual force
Approximate weight
IP44 Rated
An adapter to enable 12Vdc and 24Vdc to be powered from
Compact design
Selectable output
Input supply
Output supply
Internal fuse
Maximum output current
Approximate weight
230Vac mains supply
DH DC Version
Web Site: www.cliffordandsnell.com
2
DH AC Version
0.41 Kg dc
0.45 Kg ac
11.3Kg (25lb)
0.8Kg (1.8lb)
Email: cliffordandsnell@aol.com
Single pole changeover
dc +/- 25%, ac +/- 10%
dc 80mA, ac 60mA
Operating
Storage
4 at 28Vdc
2
120
24Vdc, 230Vac 50/60 Hz
290(g)
230Vac 50/60 Hz
12Vdc or 24Vdc selectable
500(mA)
300(mA) 12V setting
200(mA) 24V setting
Tom Cribb Road, Thamesmead,
Fax: +44 (0)20 8317 2400
Tel: +44 (0)20 8316 4477
-25 to +55 deg C
-40 to +70 deg C
95% at 40 deg C