MVS060802 COMUS, MVS060802 Datasheet
MVS060802
Specifications of MVS060802
Related parts for MVS060802
MVS060802 Summary of contents
Page 1
DATASHEET Micro Vibration Sensor MVS0608.02 Revision 2.4 Supersedes data of 2010 Dez. 07 Sensolute GmbH, 2011 2011 Mar. 22 ...
Page 2
Datasheet MVS0608.02 FEATURES Omnidirectional vibration sensor Wide supply voltage range: 1. Low operating current (e.g. Icc max. 0.2µA at Vcc 2V and R 10Meg) (e.g. Icc max. 2.0µA at Vcc 2V and R 1Meg) Noiseless R ...
Page 3
Datasheet Index 1. Operating Conditions ........................................................................................................... 4 2. Soldering Process ............................................................................................................... 4 3. Functionality ........................................................................................................................ 4 4. Qualification ........................................................................................................................ 5 5. Package mechanical data ................................................................................................... 6 5.1 Package outline ............................................................................................................ 6 5.2 Footprint ....................................................................................................................... 6 6. Ordering information ............................................................................................................ 7 ...
Page 4
Datasheet 1. Operating Conditions PARAMETER Supply voltage Current R Open R Closed Operating ambient temperature * Current consumption is determined by the resistance of the application circuit and the supply voltage. The sensor is fully passive, requires no signal conditioning, ...
Page 5
Datasheet 4. Qualification High temperature and high humidity storage Test time: 48h Test temperature: 50° C Humidity: 90% without condensation no evidence of internal corrosion after the test. High humidity storage Test time Test temperature: 40° C Test ...
Page 6
Datasheet 5. Package mechanical data 5.1 Package outline Z Figure 2: Package outline (drawing not to scale) DIMENSIONS (mm) Symbol Value (mm) L 2.850 H 1.700 B 2.450 Z 0.675 X* 1.055 *Depending on the sensor orientation in the SMD ...
Page 7
Datasheet 6. Ordering information 6.1 Tape and reel (standard-packing) Figure 4: Reel information (drawing not to scale) Figure 5: Tape information (drawing not to scale) DIMENSIONS (mm) Symbol Min 179.50 A ∅ B 2.00 8.40 C ∅ W1 8.40 Ao ...
Page 8
Datasheet 6.2 Tray (special-packing) Figure 6: Tray (drawing not to scale) Figure 7: Detail view (drawing not to scale) Sensolute GmbH, 2011 MVS0608. ...
Page 9
Datasheet 7. Important Notice Sensolute GmbH reserves the right to make corrections, modifications, enhancements, im- provements, and other changes to its products and services at any time. Customers should ob- tain the latest relevant information before placing orders and should ...