21238 Simpson, 21238 Datasheet

Thermocouple

21238

Manufacturer Part Number
21238
Description
Thermocouple
Manufacturer
Simpson
Type
J Typer
Datasheets

Specifications of 21238

Lead Length
12"
Body Material
316 Stainless Steel
Thermocouple Type
J
Peak Reflow Compatible (260 C)
No
Terminal Type
Wire Leaded
Probe Length
12 In
Temperature Sensing Max
1500°F
Case Type
J
Color
Black
Function
Thermocouple
Primary Type
Temperature
Technology
Resistive
Equipment Type
Thermocouples
Features
Quick Disconnect
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Related parts for 21238

21238 Summary of contents

Page 1

...

Page 2

... Lindbergh’s historic solo trans-Atlantic flight in 1927 to the digital controllers used to raise and lower stages at the 2004 MTV Video Music Awards (VMAs) show or the MiniMax meters which monitor the lighting at CNN, Simpson continues to pro- vide solutions for a wide variety of electrical, electronic and environmental testing and measuring applications ...

Page 3

... MiniMax M240 Temperature Meter . . . . .A5-A6 Falcon F35 & F45 . . . . . . . . . . . . . . . . . .A7-A9 2800 Series . . . . . . . . . . . . . . . . . . . . . . . . .A10 Hawk 3 H335 & H345 . . . . . . . . . . . . .A11-A12 Hawk 3 H340 Temperature Meter . . . .A13-A14 GIMA 3-Phase Power Meter . . . . . . . .A15-A17 S660 Preset Totalizer/Counter . . . . . . . . . .A18 S661 Preset Rate Counter . . . . . . . . . . . . .A19 S662 Batch/Dual Counter . . . . . . . . . . . . . .A20 S663 Rate/Totalizer Counter ...

Page 4

... Digital panel meters, such as the Simpson Hawk 3, offer scaling (the capability of the meter to asso- ciate, in engineering units, any desired value to the elec- trical input range) ...

Page 5

... Overrange indication Backlighting Polarity POWER REQUIREMENTS DC Power Power supply current Backlight supply current ACCURACY @ 25°C ENVIRONMENTAL Operating Temperature Storage Temperature Relative Humidity Warmup time Temperature Coefficient NOISE REJECTION NMRR CMRR CONVERSION Technique Rate MECHANICAL Bezel Depth Panel cutout Weight Case Material ...

Page 6

A 2 Ordering Information Mini Indicators can be configured by making an entry in each section. Example: M135-0-2-11-0 Selection M135 M145 Installation and Panel Cutout Basic Display DPM Power Function/ Unit Supply Description Selection Basic ...

Page 7

... AC TRMS V & A M235 AC TRMS V & A M245 AC Amps M235 AC Amps M245 DC Process M235 DC Process M245 Excitation Max. Current ENVIRONMENTAL Operating Temperature Storage Temperature Relative Humidity Temperature Coefficient Warmup time NOISE REJECTION NMRR CMRR CONVERSION Technique Rate FREQUENCY Technique: INPUT LEVEL (Frequency) MECHANICAL ...

Page 8

A 4 Ordering Information Mini-Max Indicators can be configured by making an entry in each section. Example: M245-1-0-71-0. Selection M235 M245 Not Available on ...

Page 9

... DIN Temperature Indicator • Jumper-selectable input type and ºC/ºF indication • Screw terminal connectors for easy installation • Unique mounting bracket allows for stacking of multiple meters Dimensions - M235, M245 & M240 2.66” Specifications DISPLAY Type Height Display resolution ...

Page 10

A 6 Ordering Information Mini-Max Indicators can be configured by making an entry in each section. Example: M240-0-91-0-F. Selection M240 Mounting Requirements Insert the Mini-Max through the panel, and then slide the mount- ing bracket ...

Page 11

... ENVIRONMENTAL Operating Temperature 0 to 55°C Storage Temperature -10 to 60°C Relative Humidity 0 to 85% non-condensing Temperature Coefficient (±0.1% of input ± 0.5 count)/°C Warm-up Time Less than 15 minutes Response Time Less than 3 seconds NOISE REJECTION NMRR 50dB, 50/60Hz CMRR (w/1K unbalanced @ 60Hz) 90dB min ...

Page 12

... Maximum 20 mA Impedance Input 200 mA 1-5 DCV 10mV 10 M 100 0-10 DCV 10mV 10 M 100 V Specifications for F45 Temperature Meters DISPLAY Type Height Decimal Point Overrange indication Polarity POWER REQUIREMENTS AC Voltages DC Voltages Power Consumption ENVIRONMENTAL Operating Temperature Storage Temperature Relative Humidity ...

Page 13

... RTD Pt100 Ohm 91 (F35) 20-199.9 Hz RMS 92 (F35) 20-1999 Hz RMS 93 (F35) 20-199.9 Hz Sq. Wave 94 (F35) 20-1999 Hz Sq. Wave (not available with AC, temperature, or frequency inputs) 0 None 1 12 DCV @ 25mA max. current 2 24 DCV @ 25mA max. current C ° ° Meets CE EMI EN-50082-1, EN-55022, EN-61000-3-2, EN-61000-3-3 (temp ...

Page 14

... DISPLAY Type Height Decimal point Overrange indication POWER REQUIREMENTS AC Voltages DC Voltages Rated Circuit to Ground Voltage ACCURACY @ 23°C, ±2°C ENVIRONMENTAL Operating Temperature Storage Temperature Relative Humidity Temp. Coefficient Warmup time CONVERSION Technique Rate MECHANICAL Bezel Depth Panel cutout Weight Ordering Information ...

Page 15

... AC functions measured at 50 Hz, include ± 1 count for each additional 100 Hz above 50 Hz ENVIRONMENTAL Operating Temperature 0 to 50°C Storage Temperature -10 to +60°C Relative Humidity <80% Ambient Temperature 25°C Temperature Drift 100 ppm/°C Warmup time 10 minutes Noise Rejection NMRR 50-60 Hz CMRR 50- CONVERSION Technique ...

Page 16

A 12 Ordering Information Hawk 3 Indicators can be configured by making an entry into each section. Example: H335-3-71-0-4-1 Basic Unit Selection H335 H345 1 120 ACV (3-1/2 only) 2 85-250 ACV (4-1/2 only) 9-36 DCV 3 85-250 ACV (3-1/2 ...

Page 17

... Display flashes “-EEEE” indicating Minimum Value Exceeded Display reads “EEEE” 100mA Max Current 85 to 250 VAC/120VAC @ 10VA DCV @ 10VA Accuracy Temperature Range 0.2% ± 2 counts -200°C to +200°C 0.2% ± 2 counts -100°C to +760°C 0.2% ± 2 counts -200°C to +1250°C 0.2% ± ...

Page 18

A 14 Installation and Panel Cutout - H335, H340, H345 3.59” 3.93” Mounting Requirements The Hawk 3 Advanced Digital Controller 1/8 DIN meters require a panel cutout of 1.77” (45mm) high and 3.62” (92 mm wide). To install the Hawk ...

Page 19

... Standard 115V±15% 45-65Hz Optional 230V±15% 45-65Hz General Display Custom backlit supertwist LCD 3 lines of .47” (12mm) digits plus .15” (3.8mm) legends ENVIRONMENTAL Temperature 14°F to 149°F (-10°C to 65°C) operating Humidity <75% RH non-condensing Programming CT Primary 5amp to 6500 amp VT Primary ...

Page 20

... GIMA 300 Meter 300 GIMA 400 Meter 400 Power Supply 1 115 VAC @ 45-65Hz 2 230 VAC @ 45-65 Hz Voltage Input 1 120/208V 2 120/240V - Split Phase 3 277/480V 4 63/110V Current Input 5 amp 1 Other 0 None For other Voltage and Current Inputs, contact Simpson Electric Company Other ...

Page 21

GIMA Options Quad Analog Output The Quad Analog Output Options Module adds four analog 4-20 DCmA outputs to any standard GIMA Series Power Meter. All out- puts are isolated from the metering elements to provide safe connec- tion to external ...

Page 22

... VLT 0.2DCV guaranteed low, VUT = 3.0DCV (max) VLT 0.9DCV VUT =3.15DCV (max) 0°C to +40°C -10°C to +60°C 0-80% non-condensing for temperatures less than 32°C, decreasing linearly to 50% at 40°C 25°C ±100ppm/°C 15 minutes 3.93" x 2.04" x .52" (99.8mm x 51.8mm x 13.2mm) 3.24" (82.3mm) 3.62" ...

Page 23

... VLT 0.2DCV guaranteed low, VUT = 3.0DCV (max) VLT 0.9DCV VUT =3.15DCV (max) 0°C to +40°C -10 °C to +60°C 0-80% non-condensing for temperatures less than 32°C, decreasing linearly to 50% at 40°C 25°C ±100ppm/ °C 15 minutes 3.93" x 2.04" x .52" (99.8mm x 51.8mm x 13.2mm) 3.24" (82.3mm) 3.62" ...

Page 24

... VLT 0.2DCV guaranteed low, VUT = 3.0DCV (max) VLT 0.9DCV VUT =3.15DCV (max) 0°C to +40°C -10°C to +60°C 0-80% non-condensing for temperatures less than 32°C, decreasing linearly to 50% at 40°C 25°C ±100ppm/ °C 15 minutes 3.93" x 2.04" x .52" (99.8mm x 51.8mm x 13.2mm) 3.24" (82.3mm) 3.62" ...

Page 25

... DCV VUT =3.15 DCV (max) ENVIRONMENTAL Operating Temp. 0°C to +40°C Storage Temp. -10 °C to +60°C Relative Humidity 0-80% non-condensing for temperatures less than 32°C, decreasing linearly to 50% at 40°C Ambient Temperature 25°C Temp. Coefficient (per °C) ±100ppm/ °C Warmup Time ...

Page 26

... VLT = 5.0V ±10% VUT = 7.0V ±10% 35KHz (Pulse Max) 8.75KHz (Quadrature X4 Max) 30DCV (Max) 0°C to +40°C -10°C to +60°C 0-80% non-condensing for temperatures less than 32°C, decreasing linearly to 50% at 40°C 25°C ±100ppm/ °C 15 minutes 3.93" x 2.04" x .52" (99.8mm x 51.8mm x 13.2mm) 3.24" ...

Page 27

... One flexible coupling (1/2” I.D.) and three reducing inserts (1/4”, 5/16”, 3/8”). A Simpson 12” anodized aluminum measuring wheel is the right choice to complete the setup of a length measurement system. Whether the application requires one or two, Simpson’s measuring wheels will perform accurately and reliably throughout the measuring process ...

Page 28

A 24 The SE Quadrature Dual-Shaft Encoders combine the most routinely- used features in one standard device, and are available with a selec- tion of five different resolutions (pulses/revolution). The cube-style unit uses an infrared light source and precision mechanical ...

Page 29

... Simpson Electric offers a wide range of reliable and durable analog panel meters to fulfill your application require- ments. Our products continue to set the standard for quality with each of our analog panel meter families. Century • Rugged black plastic case • Glass window for optimum viewing Round / Rectangular • ...

Page 30

... Specifications Accuracy: Movement: Tracking: Shielding: Response Time: Overload (1 sec.): Overload (Continuous): Repeatability: Dial: Resistance: Operating Temperature: Case: Pointer: Scale Length: Net Weight: 2-1/2" - Model 1287 1.75 1.31 .65 1.31 .12 1.00 +2% F.S. (Iron-Vane), +3 F.S. (Rectified) Models 1212, 1212T: Small core magnet Models 1247, 1347, 1349: Annular, rectifier ...

Page 31

Model 1379 4-1/2"-Model 1329, 1329T, 1349, 1359 (2) #1/4-28 STUD 4-1/2"-Model 1389 3-1/2"-Model 1327, 1327T, 1347, 1357 B 3 ...

Page 32

Ordering Information AC Milliammeters, Iron Vane Movement B Approx. Model/Size and Catalog Number 4 Impedance (Ohms) @ 2-1/2” Range 60 Hz Model 1257 0-10 1,650 06294 0-50 80 06295 0-100 17.2 06296 0-250 3.15 06297 0-500 0.9 06300 0-1000 .213 ...

Page 33

... Note 2: AC load meters must be used with external donut transformers. Complete instruc- tions for proper selection are included with each AC load meter. Advance assistance in selecting the appropriate transformer and determining the correct primary/secondary turns ratio can be obtained from a Simpson technical service representative or authorized service center. 4-20mA Process Meters Size 4-1/2" ...

Page 34

... Max. Input Voltage (10 sec) 150, 120V normal 280, 240V normal Dial Each dial arc is calibrated to track the specific type of movement used. Operating Temperature -4°F to +149°F (-20°C to +65°C) Case High density black plastic Pointer Knife-edge, with black matte finish Scale Length Model 2182: 1.88” ...

Page 35

Dimensions 1-1/2"-Models 2121, 2121T, 2141, MTG HOLES-.125 DIA DRILL THRU 3-1/2"-Models 2123, 2123T, 2143, 2153, 2183 4-1/2"-Model 2174 = Panel Meter Cut-out Dimensions 1 2-1/2"-Models 2122, 2122T, 2142, 2152,2182 3-1/2"-Model 2173 4-1/2"-Model 2124, 2124T, 2144, 2154, 2184 (4) #6-32 MTG. ...

Page 36

Ordering Information Milliammeters, Iron-Vane Movement Approx. Model/Size and Catalog Number Impedance 2-1/2” (ohms Range Model 2152 0-10 1,650 17680 0-50 80 17681 0-100 17.2 17682 3.15 17683 0-250 0.9 17684 0-500 AC Ammeters, Iron-Vane ...

Page 37

Taut Band DC Microammeters, Self-shielding Movement Approx. Model/Size and Catalog Number Impedance (Ohms)@ 2-1/2" 3-1/2" Model 2122T Model 2123T Range - 17495 0-5 5750 0-10 17415 17496 4900 17497 0-15 1960 17416 17417 17498 0-25 1960 17419 17500 ...

Page 38

... Movement: Suspension: Tracking: Repeatability: Shielding: Response Time: Overload (1 sec.): Overload (Continuous): Dial: Operating Temperature: Resistance: Case: Pointer: Scale Length: Net Weight: 3-1/2"-Model 923, 923T, 943, 953 1.75 1. 1/2”-Model 924, 924T, 944, 954 2% F.S. (iron vane), ±3% F.S. (rectifier) DC: Annular, self-shielding AC: Models 953 & ...

Page 39

Ordering Information AC Milliammeters, Iron Vane Movement Model/Size and Catalog Number Approx. Impedance 3-1/2" (Ohms Range Model 953 0-10 1650 TV3AMA010 0-50 80 TV3AMA050 17.2 0-100 TV3AMA100 7.16 0-150 TV3AMA150 3.15 0-250 TV3AMA250 0.9 0-500 TV3AMA500 AC ...

Page 40

Ordering Information Ammeters, Self-shielding movement Approx. Model/Size and Catalog Number Impedance (Ohms) @ 1-1/2" 2-1/2" Range Model 921 Model 922 TV1DAA001 TV2DAA001 0-1 0.050 TV1DAA002 TV2DAA002 0-2 0.025 TV1DAA003 TV2DAA003 0-3 0.0166 TV1DAA005 TV2DAA005 0-5 ...

Page 41

Glass window for optimum viewing • Rugged black plastic case • Black spade-type pointer for easy distant reading Specifications Accuracy: ±2% F.S. (Iron-Vane), ±3% F.S. (Rectifier) Frequency models: 45-55Hz ±0.3Hz (120V-240V) 55-65Hz ±0.3Hz (120V-240V) 380-420Hz ±1.2Hz (120V-240V) Wattmeters: +2% ...

Page 42

Ordering Information AC Voltmeters, Iron Vane Movement Approx. B Impedance Range (Ohms 0-5 0-10 133 300 0-15 833 0-25 3,333 0-50 16,166 0-100 0-150 25,000 41,166 0-250 50,000 0-300 0-500 83,333 125,000 0-750 * External ...

Page 43

Panel Meter Cut-out Dimensions NOTE: “T” model suffix used for Taut-Band movement 2-1/2"-Models 125, 125T, 145, 155, & 185 3-1/2"-Models 25 & 25T, 45, 55, 75, 85 & Model 25 Process Meter 3-1/2"-Model 75 .16 DIA. DRILL THRU. ...

Page 44

... Sharp clear scale. Each dial arc is calibrated to track the specific type of movement used Case High density black plastic Operating -4°F to +149°F (-20°C to +65°C) Temperature Pointer: Spade pointer with black, matte finish Model 187: 1.8” (45.7mm) Scale Length: Model 89: 3.5” (89.0mm) Model 87: 3.9” ...

Page 45

Dimensions 3-1/2"-Models 27 & 27T, 47, 57, & 1/2”-Model 29, 29T, 49, 59, 79 & 89 2-1/2"-Model 177 3-1/2"-Model 1/2”-Model 79 2-1/2"-Model 127 & 127T, 147, 157, & 187 MTG. Holes - .140 DIA ...

Page 46

Ordering Information Frequency, Self-Shielding Movement B Model/Size and Catalog Number 18 Voltage 2-1/2”" Range Model 187 45-55Hz 120V 35136 55-65Hz 120V 35138 380-420Hz 120V 15140 240V 35137 45-55Hz 55-65Hz 240V 35139 240V 35141 380-420Hz DC Voltmeters, Self-Shielding Movement Approx. Model/Size ...

Page 47

Ordering Information AC Microammeters Rectifier Type, Self Shielding Movement Model/Size and Catalog Number Approx. Impedance 2-1/2" (ohms Range Model 147 Model 47 0-100 3400 < > 0-200 2400 < > 0-300 1800 < > 0-500 1200 < ...

Page 48

... Sharp clear scale. Each dial arc is calibrated to track the specific type of movement used. Case: High density black plastic Resistance: ±15% of meter impedance Operating Temperature: -4°F to +149°F (-20°C to +65°C) Pointer: Red, knife-edge Model 553: 2.69" (68.3mm) 523: 2.92” (74.2mm) Scale Length: Model 554: 2.84" ...

Page 49

Ordering Information AC Voltmeters, Iron-Vane Movement Model/Size and Catalog Number Approx. Impedance 3-1/2” Range (Ohms) @60Hz Model 553 0-150* 25,000 15060 0-250* 41,166 15061 0-300* 50,000 15062 *Rectifier movements are available on special order. DC Microammeters, Self-Shielding Movement Model/Size and ...

Page 50

... Sharp clear scale. Each dial arc is calibrated to track the specific type of movement used. Case: Metal shielded cover with black matte finish Resistance: ±15% of meter impedance Operating Temperature: -4°F to +149°F (-20°C to +65°C) Pointer: Knife-edge with black matte finish Scale Length: Models 3323, 3343: 2.74" (70.0mm) Models 3324, 3344: 4.05" ...

Page 51

Ordering Information AC Microammeter Rectifier Type, Self-Shielding Movement Model/Size and Catalog Number Approx. Impedance 3-1/2” (ohms) @ 60Hz Range Model 3343 <> 4,000 0-100 <> Available on special order. AC Milliammeter Rectifier Type, Self-Shielding Movement Model/Size and Catalog Number Approx. ...

Page 52

B 24 Model 1357ET/Wide-Vue Model 112ET Model 55ET/Round Model 109ET Model 2153ET/Century Model 57ET/Rectangular ...

Page 53

Record “on” time of electrical equipment • No reset capability means virtually tamper- proof • Choice models • 2 sizes and 6 different case styles Dimensions 1-1/2"- Model 109ET 3 - 1/2”- Model 55ET 3 ...

Page 54

... All other models: 2.5 watts Case: Models 55ET, 57ET, 2153ET: high density plastic Models 109ET, 112ET, 1357ET: high density black acrylic Operating Temperature: -4°F to +149°F (-20°C to +65°C) Net Weight: Models 112ET, 109ET: 2.5 oz (0.07kg) Models 55ET, 57ET: 12.5 oz (0.35kg) Model 1357ET, 2153ET (0.37kg) ...

Page 55

... Case: Models 2523, 2524, 2543 & 2544: Metal Models 2123L, 2143L: Black plastic Resistance: ±15% of meter impedance Operating Temperature: -4°F to +149°F (-20°C to +65°C) Pointer: Red, knife-edge Scale Length: Models 2123L, 2523, 2543 & 2143L: 4.77" (121.16mm) Models 2524, 2544: 6.54" (166.0mm) Net Weight: Models Model 2523, 2123L, 2543 & ...

Page 56

Ordering Information B 28 Percent Motor Load Meters , Self-Shielding Movement Model/Size and Catalog Number Approx. Impedance 3-1/2” Range (Ohms) @ 60Hz Model 2543 0-5 ACA Motor Load 0.5VA Maximum* Current** * Internal transformer burden ** Dial reads 0-150% Motor ...

Page 57

... DPDT relay contacts for each control point; Each set of contacts rated at 5 amps, 120/240 VAC resistive. Frequency Response: 50-1000Hz Power: 108-132 VAC, 50-400Hz Operating Temperature: +41°F to 122°F (5°C to +50°C) Circuit-to-Ground Voltage: 250V rms maximum NOTE: DC meters meet ANSI specification C-39 1/2” ...

Page 58

... Limit) Set point Ordering Information 21671 21631 21632 21672 Temperature Range 0 to 300°F (0°C to +149° 500°F (0°C to +260° 750°F (0°C to +399° 1000°F (0°C to +538°C) 4-1/2” Model 0 to 1500°F (0°C to +815°C) 3324AIXA 0 to 2000° ...

Page 59

... DIN Rail Mounting Bracket • Fits Simpson Hawk 3, Falcon and Counters • Fits Standard Din Rail Ordering Information Din Rail Adapter Specifications Enclosure: UL94V-0 Rated ABS Attachment Clips: Spring Steel Stiffeners: Steel Installed depth: 4.20” from top of DIN Rail to front of ...

Page 60

... Insulated Soft Wire Soft-wire thermocouples are available in two insulation types. All soft-wire selections have beaded butt welded measurement junctions. Max. Operating Catalog Temperature Number Type Glass 1500°F 21238 Braid 1600°F 21239 Teflon Ordering Information Cat. No. THJ105 THJ1015 THK105 THK1015 ...

Page 61

Shunts Portable 150 amp Catalog No. 06714 Switchboard 100 amp Catalog No. 06500 Ordering Information Switchboard 50mV Shunts Portable 50mV Shunts Range Cat. Number Range Cat. Number 100 06500 1 06700 150 06503 5 06703 200 06504 10 06704 ...

Page 62

Current Transformers Model 186 Current Transformer C 4 • Optimal for remote sensing of AC current signals • Converts AC current signal to 0-10 ACV signal • For use with rectifier type analog panel meters or digital indicators • Perfect ...

Page 63

Donut Current Transformers Donut Current Transformers • Meets A.S.A C57.13 Standard •Flexible leads are UL105, 105°C CSA approved • Molded from impact and abrasive resist- ance black nylon for rugged construction • ±2% Accuracy Catalog Number Turns Ratio 01293 10:1 ...

Page 64

Donut Current Transformer Wrapping Information Donut Current Transformer Wrapping Information C Primary Turn Ratio Modification 6 Formula Where Actual Transformer Ratio Kn = Nameplate Transformer Ratio Na = Actual Number of ...

Page 65

... AC Volts - 166 Ohms/Volt Used only with Simpson AC Volt, iron vane analog panel meters or with a 0- 200 VAC digital meter using an external 25 /1W resistor across the inputs. Voltage Voltage Impedance Drop Range Reduced @ 60 Hz 0-500 ...

Page 66

DIN NEMA 4 Removable Cover • Protects 1/8 DIN indicators and controllers • Dust tight and water tight to NEMA 4 C standards 8 • Removable front cover allows access to programming buttons or scaling potentiometers Dimensions Specifications Lens ...

Page 67

... Quadrature (Counter) Options: Relays (5Amp) Programmable Analog Output RS-485 Communication RS-422 Communication Excitation Other, included: Min/Max, Peak Display Hold User Scaling Screw Terminal Connections Pin mate connector w/6” lead wire Mini-Max Falcon Hawk 3 Temperature Limited Limited C Gima Counters 9 Frequency ...

Page 68

...

Related keywords