XS1M30MA230 SQUARE D, XS1M30MA230 Datasheet - Page 59

Inductive Proximity Sensor

XS1M30MA230

Manufacturer Part Number
XS1M30MA230
Description
Inductive Proximity Sensor
Manufacturer
SQUARE D
Datasheet

Specifications of XS1M30MA230

Sensor Input
Inductive
Sensing Range
10mm
Supply Voltage Range Ac
24V To 240V
Sensor Housing
Cylindrical
Sensing Range Max
10mm
Sensor Output
NO
Output Type
NO
Wiring
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
10/02
2
Connector Cables
(U20 or K suffix; U78 or A suffix)
XSZCK101Y Micro Conn., 3 pin, 2 m, straight
XSZCK111Y Micro Conn., 3 pin, 2 m, 90°
XSZCA101Y Mini Conn., 3 pin, 2 m, straight
XSZCA111Y Mini Conn., 3 pin, 2 m, 90°
Connector
Micro
Wire color/connector pin
2 wire, AC/DC or AC
1
XSZB1
7427
3
Mini
3
BU/3
BN/2
kk
1
2
Cable
Blue
Brown
Black
AC/DC
L1
L2
9006PA
+/-
-/+
BU –
BN +
BK Output
kk
XS Tubular Inductive Sensors / 30 mm Diameter, AC/DC; Universal Standard Length
Specifications
Options
Accessories
a
q
Mechanical
Usable sensing rangea
Standard temperature range
Enclosure rating - cable
(connector, see p. 518)
Enclosure material
Tightening torque (max.)
Vibration resistance
Shock resistance
Standard target size (steel)
Differential (% of Sr)
Repeatability (% of Sr)
LED indicator type
Cable
Electrical
Voltage range – nominal
Voltage limit (including ripple)
Voltage drop (across switch), closed state
Inrush current
Minimum load current
Maximum load current
Residual (leakage) current,
open state
On delay (max.)
Off delay (max.)
Power-up delay (max.)
Protective circuitry
Agency Listings
Description
Extended temperature range cable type only
Extended cable length
Description
Plastic mounting nuts
Metal mounting nuts and lock washers
Mounting bracket, 90° steel
Mounting bracket, plastic
0.5" NPT conduit adapter length 2" (50.8 mm)
Refer to p. 351 for target material correction coefficient Km.
For devices without SCP, see p. 298 for protective fuses.
©
1997-2002 Schneider Electric All Rights Reserved
30 mm Diameter, AC/DC; Universal Standard Length
Shielded
Non-shielded
NEMA Type
IEC Type
Nickel plated brass
Plastic
Nickel plated brass
Plastic
(IEC 60068.2.6)
(IEC 60068.2.27)
Shielded
Non-shielded
A
B
C
2 wire
AC
DC
Without SCP
With SCP
Without SCP
With SCP
Without SCP
With SCP
Without SCP
With SCP
Without SCP
With SCP
Short circuit protection
Radio frequency immunity (RFI)
Electrostatic; transients; impulse
®
E 164869
CCN NRKH
Case
Sensing face
Down to -40° C (-40° F)
16.4 ft. (5 meter) cable
32.8 ft. (10 meter) cable
Aluminum
XS Tubular Inductive Sensors
0 to 8 mm
0 to 12 mm
-25° C to +80° C (-13° F to +176° F)
3, 4X, 6P, 12, 13
IP68 – P67 for B screw terminals
Nickel plated brass
PBT
PBT
50 N•m 37 (lb-ft)
20 N•m 15 (lb-ft)
25 G, amplitude +/- 2 mm, f = 10-55 Hz
50 G duration 11 ms
1.18" x 1.18" (30 mm x 30 mm)
1.41" x 1.41" (36 mm x 36 mm)
15%
3%
360° ring LED: Shows output status
One LED visible from 4 quadrants: Shows output status
2 LED indicators: Red shows output status
Green shows normal operation (SCP only)
22 AWG (0.5 mm
24 to 240 Vac (50/60 Hz), 24 to 210 Vdc
20 to 264 Vac/Vdc
5.5 V
2 A
5 mA
300 mA
200 mA
20
Vdc > 58 IEC 60947-5-2 Utilization category DC-12
0.6 mA
1.5 mA
0.2 ms
2 ms
0.3 ms
5 ms
40 ms
70ms
40 ms
70 ms
Optionalq
IEC 61000-4-3 Level 3
IEC 61000-4-2 L4; IEC 61000-4-4 L4; 60947.5.2 L3
Vdc
CR 44087
Class 3211 03
58 IEC 60947-5-2 Utilization category DC-13
Catalog Number
XSZE230
XSZE130
9006PA30
XSZB130
7427
2
Proximity Sensors
), PvR
Suffix
TF
L1
L2
255

Related parts for XS1M30MA230