Specifications of NJ40+U4+A2

Sensor Input
Inductive
Sensing Range
40mm
Supply Voltage Range Dc
10V To 60V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2-Wire DC
Consult factory for other connection options.
Terminal Connection Models
NCN15-M1K-Z2
NCB15+U4+Z2
NCN20+U4+Z2
NCN30+U4+Z2
NCN40+U4+Z2
Limit Switch
Style
Inductive Sensors
• 15 to 40 mm sensing ranges
• Limit switch style housing
• LED power and target indication
• Terminal connection wiring
2-Wire DC
Wiring Diagrams
PEPPERL+FUCHS
Model Number
Terminal Connection
Z2
Z2
Programmable
Normally open
Programmable
Normally closed
1
2
3
4
1
2
3
4
Range
(mm)
15
15
20
30
40
N.O.
N.C.
Load
Load
See pages
885-892 for
accessories
Mounting
Nonfl ush
Nonfl ush
Nonfl ush
Nonfl ush
Sensitive
Sensitive
Flush
Polarity
Polarity
Non-
Non-
Pepperl+Fuchs Inc. • 1600 Enterprise Parkway • Twinsburg, Ohio 44087-2245 • www.am.pepperl-fuchs.com
Telephone (330) 486-0001 • FAX (330) 405-4710 • E-Mail: sales@us.pepperl-fuchs.com
N.O or N.C.
N.O or N.C.
N.O or N.C.
N.O or N.C.
N.O or N.C.
Electrical
Output
®
Frequency
Switching
150 Hz
400 Hz
250 Hz
150 Hz
100 Hz
Technical Specifi cations
SUPPLY VOLTAGE
LOAD CURRENT (I
LEAKAGE CURRENT (OFF-STATE)
OUTPUT
VOLTAGE DROP AT I
HYSTERESIS
SHORT CIRCUIT AND
OVERLOAD PROTECTION
REVERSE POLARITY PROTECTED
LED INDICATION
SENSING FACE MATERIAL
STANDARDS
ENVIRONMENTAL PROTECTION
AMBIENT TEMPERATURE
APPROVALS
Housing Material
PBT w/metal base
PBT w/metal base
PBT w/metal base
PBT w/metal base
Inductive Proximity Sensors
PBT
* Illuminates when the target is between
80-100% of the nominal sensing distance.
NCN15-M1K-Z2 [N.O. or N.C.]
L
)
L
(MAX.)
Terminal housing
Terminal housing
Terminal housing
Terminal housing
Terminal housing
Connection
Electrical
30
Suffi x Z2
30
15 mm Sensing Range
30
Drawing No. 1
91
Dwg.
Normally open or normally closed
No.
-14ºF to +158ºF (-25ºC to +70ºC)
1
2
2
2
3
See dimension drawings
41
3-15% (5% typical)
LEDs
Yellow: Output Status
*Red: Precision Alignment
EN 60947-5-2
200 mA max.
5-60 VDC
≤ 1 mA
≤ 5 V
IP67
4.5 x 5.3 thru
Oblong hole
PBT
Yes
Yes
( 2 places)
20/22
M16 x 1.5
15
103
2-Wire
DC

Related parts for NJ40+U4+A2

NJ40+U4+A2 Summary of contents

Page 1

... N.C. Load 3 4 Pepperl+Fuchs Inc. • 1600 Enterprise Parkway • Twinsburg, Ohio 44087-2245 • www.am.pepperl-fuchs.com PEPPERL+FUCHS Telephone (330) 486-0001 • FAX (330) 405-4710 • E-Mail: sales@us.pepperl-fuchs.com Inductive Proximity Sensors Technical Specifi cations SUPPLY VOLTAGE LOAD CURRENT ( LEAKAGE CURRENT (OFF-STATE) OUTPUT ...

Page 2

... Inductive Proximity Sensors Limit Switch Style Drawing No. 2 NCB15+U4+Z2 [N.O. or N.C.] NCN20+U4+Z2 [N.O. or N.C.] NCN30+U4+Z2 [N.O. or N.C.] 118 15, 20, and 30 mm Sensing Range Recommended Accessories 2-Wire DC MH4-2681 UNI Mounting Brackets Model MH4-2681 UNI MH4-2057 OMH4-4950 Rotating bracket for mini limit switch ...

Page 3

... Nonfl ush NJ40+U4+E2 40 Nonfl ush NCN40+U4+E2 40 Nonfl ush NJ40+U4+A 40 Nonfl ush NPN N.O. & N.C. NJ40+U4+A2 40 Nonfl ush PNP N.O. & N.C. NCN40+U4+A2 40 Nonfl ush PNP N.O. & N.C. Micro (M12) Quick Disconnect Models Range Model Number ...

Page 4

... Inductive Proximity Sensors Limit Switch Style Wiring Diagrams 3-Wire DC Terminal Connection NPN Normally open Load PNP Normally open Load 3-Wire Drawing No. 1 and NCN15-M1K-E4 [NPN N.O. or N.C.] 4-Wire NCN15-M1K-E5 [PNP N.O. or N.C Sensing Range 106 PEPPERL+FUCHS NPN Normally open Load NPN Normally closed ...

Page 5

... DC Drawing No. 3 NJ40+U4+E [NPN N.O.] NJ40+U4+E2 [PNP N.O.] LEDs Yellow: Output Status NJ40+U4+A [NPN N.O. & N.C.] Green: Power NJ40+U4+A2 [PNP N.O. & N.C.] 128 Sensing Range Recommended Accessories MH4-2681 UNI Mounting Brackets Model Description MH4-2681 UNI Adjustable Unistrut ...

Page 6

... Inductive Proximity Sensors Limit Switch Style Inductive Sensors • sensing ranges • Limit switch style housing • LED power and target indication • Terminal connection wiring See pages 827-874 for cordsets 2-Wire AC Terminal Connection Models Range Model Number Mounting (mm) NBN15-M1K-WS 15 Nonfl ush ...

Page 7

... Adjustable bracket for mini limit switch Pepperl+Fuchs Inc. • 1600 Enterprise Parkway • Twinsburg, Ohio 44087-2245 • www.am.pepperl-fuchs.com PEPPERL+FUCHS Telephone (330) 486-0001 • FAX (330) 405-4710 • E-Mail: sales@us.pepperl-fuchs.com Inductive Proximity Sensors NJ15+U4+W [N.O. or N.C.] NJ20+U4+W [N.O. or N.C.] NJ30+U4+W [N.O. or N.C.] M16 x 1 ...

Page 8

... Inductive Proximity Sensors Limit Switch Style Inductive Sensors • sensing range • Limit switch style housing • LED target indication • All-metal terminal housing See pages 885-892 for accessories 2-Wire Terminal Connection Models AC Range Model Number Mounting (mm) 923H26Q-A7T-L 15 Wiring Diagrams 2-Wire AC ...

Page 9

... L1 (Metal Base Only) Pepperl+Fuchs Inc. • 1600 Enterprise Parkway • Twinsburg, Ohio 44087-2245 • www.am.pepperl-fuchs.com PEPPERL+FUCHS Telephone (330) 486-0001 • FAX (330) 405-4710 • E-Mail: sales@us.pepperl-fuchs.com Inductive Proximity Sensors Technical Specifi cations SUPPLY VOLTAGE SUPPLY FREQUENCY LOAD CURRENT ( LEAKAGE CURRENT (OFF-STATE) ...

Page 10

... Inductive Proximity Sensors Limit Switch Style Drawing No. 2 NJ40+U4+W4 [N.O. & N.C.] 128 Sensing Range Recommended Accessories 4-Wire AC MH4-2681 UNI Mounting Brackets Model MH4-2681 UNI Adjustable Unistrut MH4-2057 Adjustable slide bracket See pages 885-892 for complete accessory listing. 112 PEPPERL+FUCHS LEDs ...

Page 11

... Base Only) Pepperl+Fuchs Inc. • 1600 Enterprise Parkway • Twinsburg, Ohio 44087-2245 • www.am.pepperl-fuchs.com PEPPERL+FUCHS Telephone (330) 486-0001 • FAX (330) 405-4710 • E-Mail: sales@us.pepperl-fuchs.com Inductive Proximity Sensors Technical Specifi cations SUPPLY VOLTAGE LOAD CURRENT ( LEAKAGE CURRENT (OFF-STATE) ...

Related keywords