S18SP6FF50Q BANNER ENGINEERING, S18SP6FF50Q Datasheet
S18SP6FF50Q
Specifications of S18SP6FF50Q
Related parts for S18SP6FF50Q
S18SP6FF50Q Summary of contents
Page 1
Sensing Mode Opposed Retroreflective Polarized P Retroreflective Diffuse Fixed-Field * Standard 2 m (6.5') cable models are listed. • (30') cable: add suffix “W/30” (e.g., S186E W/30). • 4-pin Euro-style QD models: add suffix “Q” (e.g., S186EQ). A ...
Page 2
... R2 Figure 1. Fixed-field concept As a general rule, the most reliable sensing of an object approaching from the side occurs when the line of approach is parallel to the sensing axis. Figure 2. Fixed-field sensing axis Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 or ...
Page 3
... Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 S18 Sensors – dc-Voltage Series Color Sensitivity The effects of object reflectivity on cutoff distance, though small, may be important for some applications expected that at any given cutoff setting, the actual cutoff distance for lower reflectance targets will be slightly shorter than for higher reflectance targets (see Figure-of-Merit information on page 5) ...
Page 4
... Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation) Certifications 4 P/N 121522 Specifications wired as a normally open marginal signal alarm output, depending upon hookup to power supply Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 ...
Page 5
... Performance based on use of a model BRT-3 retroreflector (3" diameter). Actual sensing range may be more or less than specified, depending on the efficiency and reflective area of the retroreflector used. Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 S18 Sensors – dc-Voltage Series ...
Page 6
... NOTE: QD hookups are functionally identical. QD Models Yellow LED Green LED Jam Nuts (2 Provided Thread 37.0 mm 78.0 mm* (1.46") (3.07") PNP (Sourcing) Outputs Standard Hookup 30V dc bu – bk Load wh Load Alarm Hookup bn – 30V Load wh Alarm Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 ...
Page 7
... Right-angle MQDC-430RA WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • ...