MC33972ATEW Freescale Semiconductor, MC33972ATEW Datasheet - Page 16

no-image

MC33972ATEW

Manufacturer Part Number
MC33972ATEW
Description
IC SWITCH DETECT SPI 32-SOIC
Manufacturer
Freescale Semiconductor
Datasheets

Specifications of MC33972ATEW

Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC33972ATEW
Manufacturer:
FREESCAL
Quantity:
3
Part Number:
MC33972ATEW
Manufacturer:
FREESCALE
Quantity:
37 268
Part Number:
MC33972ATEW
Manufacturer:
FREESCALE
Quantity:
37 268
Part Number:
MC33972ATEW
Manufacturer:
ST
0
Part Number:
MC33972ATEW
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC33972ATEW/R2
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
MC33972ATEWR2
Manufacturer:
TOSHIBA
Quantity:
8 240
Part Number:
MC33972ATEWR2
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC33972ATEWR2
0
TRI-STATE REGISTER
node as high-impedance
register bit to logic [1], the input will be high-impedance
regardless of the metallic command setting. The comparator
Table 10. Tri-State Command
ANALOG SELECT REGISTER
MCU using the analog command
IC is a 22-to-1 analog multiplexer. The voltage present on the
selected input pin is buffered and made available on the
AMUX output pin. The AMUX output pin is clamped to a
maximum of V
present on the input pin. After an input has been selected as
the analog, the corresponding bit in the next SO data stream
will be logic [0]. When selecting a channel to be read as
analog, the user must also set the desired current (16 mA,
2.0 mA, or high-impedance). Setting bit 6 and bit 5 to 0,0
Table 11. Analog Command
16
33972
FUNCTIONAL DEVICE OPERATION
OPERATIONAL MODES
23
23
0
0
0
The tri-state command is use to set the SPn or SGn input
The analog voltage on switch inputs may be read by the
22
22
0
0
0
Tri-State Commands
21
21
0
0
Analog Command
0
DD
20
20
0
0
0
volts regardless of the higher voltages
19
1
1
19
0
(Table
18
0
0
18
1
17
0
1
10). By setting the tri-state
17
1
(Table
16
1
0
16
0
11). Internal to the
15
X
X
15
X
14
X
X
14
X
sg13 sg12 sg11 sg10 sg9 sg8 sg7 sg6 sg5 sg4 sg3 sg2 sg1 sg0
13
X
13
X
12
12
X
X
Not used
11
X
11
X
on each input remains active. This command allows the use
of each input as a comparator with a 4.0 V threshold. The
MCU may change or update the tri-state register via software
at any time in Normal mode.
selects the input as high-impedance. Setting bit 6 and bit 5 to
0,1 selects 2.0 mA, and 1,0 selects 16 mA. Setting bit 6 and
bit 5 to 1,1 in the analog select register is not allowed and will
place the input as an analog input with high-impedance.
currents for all SGn and SPn inputs
command does not allow pull-down currents on the SPn
inputs. Setting the current to 16 or 2.0 mA may be useful for
reading sensor inputs. Further information is provided in the
Typical Applications
page 21. The MCU may change or update the analog select
register via software at any time in Normal mode.
10
X
Analog currents set by the analog command are pull-up
10
X
X
9
X
9
Command Bits
X
8
X
8
X
7
sp7 sp6 sp5 sp4 sp3 sp2 sp1 sp0
7
section of this datasheet beginning on
Current Select Analog Channel Select
16 mA 2.0 mA
Analog Integrated Circuit Device Data
6
6
5
5
Freescale Semiconductor
4
(Table
4
0
3
3
0
11). The analog
2
2
0
1
1
0
0
0
0

Related parts for MC33972ATEW