HMC1043 Honeywell Microelectronics & Precision Sensors, HMC1043 Datasheet - Page 2

Magnetic Sensor

HMC1043

Manufacturer Part Number
HMC1043
Description
Magnetic Sensor
Manufacturer
Honeywell Microelectronics & Precision Sensors
Datasheet

Specifications of HMC1043

Supply Voltage
3V
Sensitivity Range
1 MV/V
Sensor Terminals
SMD
Supply Current
10mA
Magnetic Field Max
6G
Axis Configuration
Three
Magnetic Field Min
-6G
Sensor Output
Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HMC1043
Manufacturer:
HITTITE
Quantity:
5 000
Part Number:
HMC1043L-TR
Manufacturer:
DIPTRONIC
Quantity:
34 000
Part Number:
HMC1043LC3
Manufacturer:
NSC
Quantity:
201
Part Number:
HMC1043LC3ETR
Manufacturer:
MICROCHIP
Quantity:
492
Part Number:
HMC1043LC3TR
Manufacturer:
NXP
Quantity:
450
HMC1043
SPECIFICATIONS
Bridge Elements
Set/Reset Straps
Offset Straps
* Tested at 25°C except stated otherwise.
2
Characteristics
Supply
Resistance
Operating Temperature
Storage Temperature
Humidity
MSL
Field Range
Linearity Error
Hysteresis Error
Repeatability Error
Bridge Offset
Sensitivity
Noise Density
Resolution
Bandwidth
Disturbing Field
Sensitivity Tempco
Bridge Offset Tempco
Bridge Ohmic Tempco
Cross-Axis Effect
Max. Exposed Field
X,Y, Z sensor
Orthogonality
Resistance
Current
Resistance Tempco
Resistance
Offset Constant
Resistance Tempco
0.1% duty cycle, or less, 2 sec current pulse
Cross field = 1 gauss, Happlied = ±1 gauss
T
A
= -40 to 125°C, No Set/Reset, ±1 gauss
Use S/R pulse to restore sensitivity.
Set/Reset Current = 0.5A per strap
Full scale (FS) – total applied field
No perming effect on zero reading
Magnetic signal (lower limit = DC)
Field applied in sensitive direction
T
T
Field = 0 gauss after Set pulse
A
T
Vbridge=5V, T
Measured from OFF+ to OFF-
50Hz Bandwidth, Vbridge=5V
= -40 to 125°C, With Set/Reset
Measured from S/R+ to S/R-
Sensitivity starts to degrade.
A
Vbridge referenced to GND
A
3 sweeps across ±3 gauss
3 sweeps across ±3 gauss
= -40 to 125°C, Ibridge=5mA
Offset = (OUT+) – (OUT-)
Moisture Sensitivity Level
= -40 to 125°C, Vbridge=5V
Bridge current = 10mA
@ 1kHz, Vbridge=5V
measured Vb to Vss
Best fit straight line
Ambient, unbiased
T
T
X to Z or Y to Z
Tested at 85°C
A
A
X toY sensors
Conditions*
= -40 to 125°C
= -40 to 125°C
DC Current
per bridge
± 1 gauss
± 3 gauss
± 6 gauss
Ambient
A
= -40 to 125°C
-3700
-1.25
2100
3300
3500
Min
800
265
1.8
-40
-55
0.8
1.5
20
10
-6
2
-3400
-1000
1000
±700
2400
3700
3900
0.06
±0.5
±0.3
0.01
Typ
333
120
±10
3.0
0.1
0.4
1.4
0.1
1.0
1.5
2.5
50
13
10
3
5
3
10000
+1.25
-3100
1500
2700
4100
4300
Max
500
125
150
1.2
10
85
+6
16
3
8
www.honeywell.com
mV/V/gauss
nV/sqrt Hz
mA/gauss
ppm/°C
ppm/°C
ppm/°C
ppm/°C
ppm/°C
degree
gauss
gauss
gauss
Units
ohms
ohms
mV/V
ohms
ohms
Volts
%FS
%FS
%FS
gauss
%FS
MHz
Amp
°C
°C
%
-

Related parts for HMC1043