HIH-4030-001 Honeywell Sensing and Control, HIH-4030-001 Datasheet
HIH-4030-001
Specifications of HIH-4030-001
Related parts for HIH-4030-001
HIH-4030-001 Summary of contents
Page 1
... Manufacturer) users. Direct input to a controller or other device is made possible by this sensor’s near linear voltage output. With a typical current draw of only 200 μA, the HIH-4030/4031 Series is often ideally suited for low drain, battery operated systems. Tight sensor interchangeability reduces or eliminates OEM production calibration costs ...
Page 2
... Non-condensing environment. When liquid water falls on the humidity sensor die, output goes to a low rail condition indicating no humidity. FACTORY CALIBRATION DATA HIH-4030/31 Sensors may be ordered with a calibration and data printout. See Table 2 and the order guide on the back page. TABLE 2. EXAMPLE DATA PRINTOUT ...
Page 3
... FIGURE 1. OPERATING ENVIRONMENT (Non-condensing environment for HIH-4030 catalog listings only.) FIGURE 2. STORAGE ENVIRONMENT (Non-condensing environment for HIH-4030 catalog listings only.) 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% -40 -20 Recommended storage zone 100 Temperature ºC Humidity Sensors 120 140 Honeywell Sensing and Control ...
Page 4
... HIH-4030/31 Series FIGURE 3. TYPICAL OUTPUT VOLTAGE VS RELATIVE HUMIDITY (At 25 ºC and 5 V.) 4 3.5 3 2.5 2 1.5 1 0.5 0 FIGURE 4. TYPICAL OUTPUT VOLTAGE (BFSL) VS RELATIVE HUMIDITY (At 0 ºC, 70 ºC and 5 V.) 4.5 4 3.5 3 2.5 2 1 www.honeywell.com/sensing Relative Humidity (%RH Relative Humidity (%) Sensor Response Sensor Response ...
Page 5
... FIGURE 5. HIH-4030 MOUNTING DIMENSIONS (For reference only. mm/[in]) Humidity Sensors Honeywell Sensing and Control 5 ...
Page 6
... HIH-4030/31 Series FIGURE 6. HIH-4031 MOUNTING DIMENSIONS (For reference only. mm/[in]) FIGURE 7. HIH-4031 PCB LANDING PATTERN (For reference only. mm/[in]) 6 www.honeywell.com/sensing ...
Page 7
... HIH-4031-003 Covered, filtered integrated circuit humidity sensor, SMD, calibration and data printout, 1000 units on tape and reel HIH-4030-001S Sample pack: covered integrated circuit humidity sensor, SMD, five units on tape HIH-4030-003S Sample pack: covered integrated circuit humidity sensor, SMD, calibration and data printout, five units on ...
Page 8
WARNING MISUSE OF DOCUMENTATION • The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. • Complete installation, operation, and maintenance information is provided in the instructions supplied with ...