DFC.9000 UCC, DFC.9000 Datasheet

FLOW TRANSDUCER, COMPACT

DFC.9000

Manufacturer Part Number
DFC.9000
Description
FLOW TRANSDUCER, COMPACT
Manufacturer
UCC
Datasheet

Specifications of DFC.9000

Pressure Max
20bar
Accuracy
± 2%
Liquid Measuring Range
1l/min To 25l/min
Connection Size
0.375"
Flow Rate Max
25l/min
Flow Rate Min
1l/min
Supply Voltage Dc Max
5V
External Depth
27mm
External Length / Height
29mm
External Width
52mm
Flow L / Min Max
25
Features & Benefits
Specification
Construction:
Body
Rotor
Shaft
Shaft
Retainers Grilamid TR55.
Operation:
Infra-red.
Maximum working pressure:
20 bar.
Pressure drop:
Max 0.1 bar at 15 l/min.
Flow range:
1 to 25 I/min.
(Accepts reverse flow).
Calibration:
‘K’ Factor 752 pulses per litre,
typical.
Subject to application.
Accuracy:
±2% typical.
Installation Details
Red wire
Green wire
Blue wire
Parker Hannifin
Filter Division Europe
FDHB200UK. Section 46
Flowmeters & Monitors
Dataflow Compact - Inline Flow
Transmitter
Grilamid – TR55.
18% PTFE filled
nylon.
Stainless steel.
+5V supply
Output signal
0V supply
12.0 TYP
8.0 TYP
Repeatability:
±1%.
Temperature range:
+5°C to +70°C.
Overall dimensions:
52mm x 29mm x 27mm.
Weight:
16 grams.
Connections:
3
Cable length:
300mm.
Power supply:
5 Vdc.
Output signal:
5 Vdc - square wave
/
8
BSP
3.5
20.0
52.0
Pulse output signal for flows up to 25 l/min.
Lightweight and robust.
Operates in any plane. Simple to install.
Low cost flow measurement.
Negligible pressure drop.
Accepts reverse flow.
3
Water or compatible clear fluids only.
Ideal for washing machines, showers and
vending machines.
/
8
BSP male connection.
281
Dataflow Compact – The Low Cost Transmitter
The Dataflow Compact Transmitter was designed to offer
OEM’s and end users alike a means of monitoring low flows
on liquids with an electronic output signal – but at LOW COST.
Fluid passes through the one piece sensor body impacting on
the twin vaned turbine rotor, causing it to rotate at a speed
proportional to the flow rate. Two opposing photo-transistors
are mounted either side of the rotor and externally of the clear
sensor body, these generate a continuous signal.
As the rotor spins each blade obscures the infra red signal.
This is then converted into an industry standard pulse output
signal – compatible with inexpensive display units for flow rate,
totalising, batch control and large, central control systems.
The lightweight Grilamid body with its virtually unrestricted flow
path, offers negligible pressure drop for flows up to 25 I/min
and withstanding pressures up to 20 bar.
Flow Rate • Totalising • Batch Control and applications
in many industries
Dataflow Compact Transmitters are small and very robust
having been developed and tested extensively in industry
applications where space is a restriction. Dataflow Compact
with its Grilamid body and BSP connections can be installed
almost anywhere and once installed will give accurate and
reliable output signalling.
Ordering Information
Standard products table
Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.
Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.
Product number
DFC9000100
DFC.9000100
Supercedes
Dataflow compact transmitter
Flowmeters & monitors
Description

Related parts for DFC.9000