26616 Gems Sensors Inc, 26616 Datasheet

Flow Switch

26616

Manufacturer Part Number
26616
Description
Flow Switch
Manufacturer
Gems Sensors Inc
Datasheet

Specifications of 26616

Accuracy
+/-10%
Operating Pressure Range
400psig
Circuitry
SPDT
Body Material
Bronze
Contact Current Ac Max
500mA
Mounting Type
Conduit
Power Rating
20VA
Operating Temperature Range
0°C To +25°C
Port Size
1"
Connection Size
1"
Contact Voltage Ac Max
250V
Features
Straight-Through Flow Path
Flow Range
5 To 15 GPM
Rohs Compliant
No
Accuracy %
10%
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
G-18
FS-200 Series – General Purpose,
Straight-Through Flow Path
Flow Rate Settings: Fixed: 0.5 GPM to 100.0 GPM
Port Size: 1˝ NPT to 2˝ NPT
Primary Construction Material: Bronze or Stainless Steel
Setting Type: Fixed or Adjustable
The FS-200 Series offers accurate flow detection, with 1% repeatability, over a broad
range of flow settings and port sizes. Its durable construction delivers long-life
reliability in either water or oil. Generous flow paths keep pressure drop low. These
switches are ideal for detection of improper flow rates in high volume lubrication,
cooling or process systems.
FS-200 Adjustable Series switches offer the same accuracy and are as rugged as those
with fixed settings, but provide one additional feature: external adjustability. With these
versatile switches your choice of flow settings is diverse within a given range. An
ordinary, flat-blade screwdriver is all that’s required for the actuation adjustment.
Specifications
Wetted Materials
Pressure Rating
Operating Temperature
Repeatability
Set Point Accuracy
Set Point Differential
Switch*
Electrical Termination
*See “Electrical Data” on Page X-5 for more information.
Housing
Shuttle
Bonnet
Spring
Other Wetted Parts
Operating
Proof
FS-200
FS-200 Adjustable
FS-200
FS-200 Adjustable
Adjustable: 1.0 GPM to 15.0 GPM
Bronze or 316 Stainless Steel
Bronze
Teflon
Bronze or Stainless Steel
316 Stainless Steel
Viton
400 PSIG (27.6 bar) @ 100°F (37.8°C)
800 PSIG (55.2 bar) @ 100°F (37.8°C)
-20°F to +300°F (-29°C to +148.9°C)
-20°F to +200°F (-29°C to +93.3°C)
1% Maximum Deviation
±10%
15% Maximum
SPDT, 20 VA
No. 18 AWG, 24˝ L., Polymeric Lead Wires
Red NC, Black Common, Orange NO
®
®
, Ceramic
Visit www.GemsSensors.com for most current information.
POLYMERIC JACKET
FS-200 Series
FS-200 Adjustable
Dimensions
Notes:
1. Adjustable versions available in 1 inch port sizes only.
2. Standard calibration is in water with units in a horizontal position.
3. Viscosity changes will affect setpoints. Typically, as viscosity
4. Consult Gems for special applications.
Adjustable
#18 AWG., 24" L.,
increases setpoints will decrease.
FS-200
FS-200
Model
and
B
Port Size
1-1/4˝ ss 4-1/2 (114.3) 3-3/16 (80.9) 2-3/16 (55.5)
1-1/4˝
1-1/2˝
NPT
A
4-1/2 (114.3) 3-1/2 (88.9)
5-3/8 (136.5)
3-1/4 (82.6)
inch (mm)
4 (101.6)
1/2" -NPT
A
BONNET
SWITCH
HOUSING
NPT PORT
INLET PORT
3-3/16 (80.9) 2-3/16 (55.5)
inch (mm)
4 (101.6)
3 (76.2)
B
U.L. Recognized
File No. E31926
CSA Listed —
File No. LR30200
and LR22666
FM Approved —
File No. 0A8A3.AE
and 1H3A2.AX
U.L. Recognized
File No. E31926
CSA Listed —
File No. LR22666
FM Approved —
File No. 0Q2A8.AE
1-25/32 (45.2)
C
3-3/32 (78.5)
2-1/2 (63.5)
inch (mm)
C Hex

Related parts for 26616

26616 Summary of contents

Page 1

... The FS-200 Series offers accurate flow detection, with 1% repeatability, over a broad range of flow settings and port sizes. Its durable construction delivers long-life reliability in either water or oil. Generous flow paths keep pressure drop low. These switches are ideal for detection of improper flow rates in high volume lubrication, cooling or process systems ...

Page 2

... Part Numbers 1.0-6.0 26615 5.0-15.0 26616 2.0-8.0 26838 Visit www.GemsSensors.com for most current information. SHUTTLE TYPE Pressure Drop - Typical 1˝ NPT and 1-1/2˝ NPT Ports 4 3 Part No. 27051 2 Part No. 27085 ...

Related keywords