FS5.A.1L.195 IST, FS5.A.1L.195 Datasheet
![SENSOR, FLOW, GAS, MOLDED](/photos/19/90/199006/126695307-40_sml.jpg)
FS5.A.1L.195
Specifications of FS5.A.1L.195
Related parts for FS5.A.1L.195
FS5.A.1L.195 Summary of contents
Page 1
... Using a bridge circuit, the differing resistance value of two elements leads to different (self) heating. The (self) heating is dependent upon the applied voltage, the mass flow, and the media in which the sensor is located. Higher voltage increases self heating, a higher flow rate increases cooling ...
Page 2
... Flow Sens FS5L / FS5LA Thermal Mass Flow Sensor for all-purpose use in Liquids Technical Data Measuring principle thermal Measuring range 0 ... 10 m/s Response sensitivity 0.01m/s Accuracy < 3% current measuring value (dependent on electronic and calibration) Warm up time < 1 min (depending on mounting) Response time t < ...
Page 3
... The two elements (heaters RH and sensor Rs) can be interconnected in accordance with following schematic in a bridge. Resistances R1, R2 and R3 are to be dimensioned correctly according sample circuit to be seen below. The bridge is balanced, if the temperature difference ( T) amounts the desired value between Rs and RH of e.g. ...