Mounting the End Plate (PFP-M)
An End Plate should be used if there is a possibility of the Amplifier
Unit moving, e.g., due to vibration. If a Mobile Console is going to be
mounted, connect the End Plate in the direction shown in the following
diagram.
Mounting the Mobile Console Head
Leave a gap of at least 20 mm between the nearest Amplifier Unit and
the Mobile Console head.
Fiber Connection
The E3X Amplifier Unit has a lock button for easy connection of the
Fiber Unit. Connect or disconnect the fibers using the following
procedures:
1. Connection
Open the protective cover, insert the fibers according to the fiber
insertion marks on the side of the Amplifier Unit, and lower the lock
lever.
Note: If one of the fibers from the Fiber Unit has a white line, such as with a Coaxial
Fibers with E39-F9 Attachment
Lock button
Fiber
Fiber Unit
Sensor, that fiber is for the Emitter. Insert it into the Emitter section. Refer to
Dimensions for the Fiber Unit to see if there is an Emitter fiber.
Fiber insertion mark
13 mm
9 mm
Locked
End Plate
20 mm
9 mm
Unlocked
Insertion position
Protective cover
Fibers That Cannot Be Free-Cut (with Sleeves)
2. Disconnecting Fibers
Remove the protective cover and raise the lock lever to pull out the
fibers.
● Adjusting
Mutual Interference Protection Function
There may be some instability in the digital display values due to light
from other sensors. If this occurs, decrease the sensitivity (i.e.,
decrease the power or increase the threshold) to perform stable
detection.
EEPROM Writing Error
If the data is not written to the EEPROM correctly due to a power
failure or static-electric noise, initialize the settings with the keys on
the Amplifier Unit. ERR/EEP will flash on the display when a writing
error has occurred.
Optical Communications
Several Amplifier Units can be slid together and used in groups. Do
not, however, slide the Amplifier Units or attempt to remove any of the
Amplifier Units during operation.
● Others
Protective Cover
Always keep the protective cover in place when using the Amplifier
Unit.
Mobile Console
Use the E3X-MC11-SV2 Mobile Console for the E3X-DA-S-series
Amplifier Units.
Note: 1. To maintain the fiber properties, confirm that the lock is released
2. Be sure to lock or unlock the lock button within an ambient
before removing the fibers.
temperature range between −10°C and 40°C.
Locked
13 mm
Unlocked
9 mm
E3X-DA-S/MDA
Protective cover
16