HX 10-NP LEM, HX 10-NP Datasheet - Page 2

CURRENT TRANSDUCER

HX 10-NP

Manufacturer Part Number
HX 10-NP
Description
CURRENT TRANSDUCER
Manufacturer
LEM
Datasheet

Specifications of HX 10-NP

Current Measuring Range Ac
DC, AC, Pulsed, Mixed
Current Measuring Range Dc
DC, AC, Pulsed, Mixed
Supply Voltage Range Dc
12V To 15V
Sensor Output
Voltage
Svhc
No SVHC
Accuracy
1%
Response Time
3µs
Current Consumption
20mA
Current Range Ac
DC, AC, Pulsed, Mixed
Current Range Dc
DC, AC,
Rohs Compliant
Yes
Accuracy %
1%
Bandwidth
50kHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Dimensions HX 05..15-NP
Mechanical characteristics
071029/8
General tolerance
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Terminal Pin Identification
1...... -15V
2...... 0V
3...... +15V
4...... Output
5...... Primary 1 input Current(-)
7...... Primary 1 input Current(+)
6...... Primary 2 input Current(-)
8...... Primary 2 input Current(+)
3
(in mm. 1 mm = 0.0394 inch)
4
3
2
1
± 0.5 mm
-V or 0
10.85
OUT
10.85
+V
19 Max.
0
6
5
4
4
8
7
d
Safety
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Caution! Risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Top view
Primary conductor diameter
Secondary pins dimension
0.5 x 0.25
HX 05-NP 10-NP
HX
d
d
15.4 Max.
05-NP
0.8
6
Lot No.
HX 05-NP
0.8
41123
1.0
10-NP
1.0
15-NP
1.2
www.lem.com
Page 2/2