HTFS 200-P LEM, HTFS 200-P Datasheet - Page 2

Current Transducer

HTFS 200-P

Manufacturer Part Number
HTFS 200-P
Description
Current Transducer
Manufacturer
LEM
Datasheet

Specifications of HTFS 200-P

Current Measuring Range Ac
± 300A
Current Measuring Range Dc
± 300A
Supply Voltage Range Dc
4.75V To 5.25V
Sensor Output
Voltage
Length/height, External
16.5mm
Accuracy
± 1%
Response Time
7µs
External Depth
46mm
External Width
40mm
Rohs Compliant
Yes
Accuracy %
1%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current Transducer HTFS 200..800-P
V
V
V
V
V
Notes :
LEM Components
b
b
d
e
w
Safety :
Caution, risk of danger
Caution, risk of electrical shock
Insulation category
1)
2)
3)
It is possible to overdrive V
between 2 - 2.8 V providing its ability to sink or source approx. 2.5 mA.
Excluding offset.
Small signal only to avoid excessive heatings of the magnetic core.
Nominal Voltage
with IEC 61010-1 standards and following conditions
Nominal Voltage
with EN 50178 standards and following conditions
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn
R.m.s. voltage for partial discharge extinction @ 10pC > 1
Impulse withstand voltage 1.2/50µs
If insulated cable is used for the primary circuit, the
voltage category could be improved with the following table :
- Single insulation
- Over voltage category III
- Pollution degree 2
- Heterogeneous field
- Reinforced insulation
- Over voltage category III
- Pollution degree 2
- Heterogeneous field
Cable insulation (primary)
HAR 03
HAR 05
HAR 07
REF
This transducer shall be used in accordance with manufacturer instruction.
Power supply shall be a low voltage source and shall have an efficient
protective system against over current.
Power supply must incorporate a circuit breaker.
This transducer shall be used in an electric/electronic equipment in respect
of standards rules and applicable safety requirements.
Primary bar and output terminals can provide hazardous voltage.
This transducer is a built in device, of which conducting parts must be
inaccessible by installation.
Protective envelope or additional shield must be used.
with an external reference voltage
Category
300V CAT III
400V CAT III
500V CAT III
150
150
2.5
4
V r.m.s.
V r.m.s.
kV
kV
kV
w w w .lem.com