HAIS 150-P LEM, HAIS 150-P Datasheet - Page 2

CURRENT TRANSDUCER

HAIS 150-P

Manufacturer Part Number
HAIS 150-P
Description
CURRENT TRANSDUCER
Manufacturer
LEM
Datasheet

Specifications of HAIS 150-P

Current Measuring Range Ac
DC, AC, Pulsed, Mixed
Current Measuring Range Dc
DC, AC, Pulsed, Mixed
Operating Frequency Range
DC To 50kHz
Sensor Output
Voltage
Svhc
No SVHC
Accuracy
1%
Response Time
5µs
Current Consumption
22mA
Current Range Ac
DC, AC, Pulsed, Mixed
Current Range Dc
DC, AC,
Rohs Compliant
Yes
Accuracy %
1%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Safety
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the following
manufacturer's operating instructions.
Caution! Risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
070827/7
Current Transducer HAIS 50..400-P and HAIS 50..100-TP
T
T
m
V
V
V
V
V
dCp
dCl
CTI
A
S
b
b
d
e
w
General data
Isolation characteristics
Ambient operating temperature
Ambient storage temperature
Mass (in brackets : TP version)
Standards
Rated isolation voltage rms
with IEC 61010-1 standards and following conditions
Rated isolation voltage rms
with EN 50178 standards and following conditions
Rms voltage for AC isolation test, 50 Hz, 1 min
Partial discharge extinction voltage rms @ 10pC
Impulse withstand voltage 1.2/50 µs
Creepage distance
Clearance distance
Comparative tracking index (Group I)
If insulated cable is used for the primary circuit, the
voltage category could be improved with the following table :
Cable insulation (primary)
HAR 03
HAR 05
HAR 07
- Single insulation
- Over voltage category III
- Pollution degree 2
- Heterogeneous field
- Reinforced insulation
- Over voltage category III
- Pollution degree 2
- Heterogeneous field
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
HAIS 50..400-P
HAIS 50..100-TP > 1.4
Category
450V CAT III
550V CAT III
650V CAT III
- 40 .. + 85 °C
- 40 .. + 85 °C
20 (30)
EN 50178: 1997
300
600
2.5
> 1
8
> 8
> 8
> 600
V rms
V rms
m m
m m
kV
kV
kV
kV
g
www.lem.com
Page 2/3

Related parts for HAIS 150-P