37000 Simpson, 37000 Datasheet - Page 30
37000
Manufacturer Part Number
37000
Description
Current Transducer
Manufacturer
Simpson
Type
Inductiver
Specifications of 37000
Current Measuring Range Ac
0A To 5A
Supply Voltage Range Dc
21.6V To 26.4V
Sensor Output
Current
Frequency Max
60Hz
Transducer Output Current Dc Max
20mA
Length
69.85mm
Frequency Min
60Hz
Accuracy
0.5%
Frequency Response
60 Hz
Function
Current
Height
4.22 in.
Material, Stud
Brass
Output
Current
Primary Type
Current
Range, Measurement
5 A
Technology
Inductive
Width
0.071 in.
Equipment Type
Current Transducer
Range
0 - 5
Accuracy %
0.5%
Current Range Ac
0-5A
Current Range Dc
4-20mA
External Depth
59.94mm
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
Digital DC process panel indicators and controllers
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
37000200000
Manufacturer:
Littelfuse
Quantity:
40 000
Company:
Part Number:
37000400000
Manufacturer:
WICKMANN
Quantity:
3 150
Company:
Part Number:
37000500430
Manufacturer:
SANDISK
Quantity:
1 500
Company:
Part Number:
37000500430
Manufacturer:
ITT
Quantity:
200
B
2
1-1/2"-Model 1212, 1212T
• Clear acrylic window for wide angle
• Rugged black plastic case
• Black spade pointer for easy distant reading
• Optional behind-panel mounting bezel kit
Dimensions
1.76
visibility
.41
.53
.86
.55
1.50
DIA.
1.55
DIA.
(2) #8-32 STUDS
(4) #4-40 MTG. STUDS
MTG. HOLES- .128 DIA. DRILL THRU
.65
1.75
1.00
1.31
.12
.65
1.31
Specifications
Accuracy:
Movement:
Tracking:
Shielding:
Response Time:
Overload
(1 sec.):
Overload
(Continuous):
Repeatability:
Dial:
Resistance:
Operating
Temperature:
Case:
Pointer:
Scale Length:
Net Weight:
2-1/2" - Model 1287
+2% F.S. (Iron-Vane), +3 F.S. (Rectified)
Models 1212, 1212T: Small core magnet
Models 1247, 1347, 1349: Annular, rectifier
Models 1257, 1357, 1359: Iron-vane, magnetically
damped
+3%
Calibration is unaffected by magnetic panel mounting.
1.5 seconds maximum
10 times F.S.
1.5 times F.S.
2%: AC Current, DC Process
3%: AC Voltage, DC Voltage, Wattmeters
0.5%: DC Current
Sharp clear scale. Each dial arc is calibrated to track the
specific type of movement used.
+15% of meter impedance
-4°F to +149°F (-20°C to +65°C)
High density black plastic
Model 1212: Black lance;
All other models: Spade with black matte finish
Model 1212, 1212T: 1.50" (38.1mm);
Model 1227, 1227T, 1247, 1257: 2.3" (58.4mm)
Model 1327, 1327T, 1347, 1357, 1377: 3.14" (79.9mm);
Model 1329, 1329T, 1349, 1359, 1379: 3.93" (100mm)
Model 1212, 1212T: 2oz (0.06kg);
Model 1257: 4 oz. (0.11kg)
Model 1359: 5 oz. (0.14kg)
Model 1227, 1227T: 6oz (0.17kg)
Model 1327, 1327T, 1347: 8oz (0.23kg);
Model 1329, 1329T, 1349, 1377: 9oz (0.26kg)