90B03ST Grayhill Inc, 90B03ST Datasheet
90B03ST
Specifications of 90B03ST
Available stocks
Related parts for 90B03ST
90B03ST Summary of contents
Page 1
... PPA or PA46. The 10 position 90 Series family will be converted in the next 60 days. Part Numbers Affected The table below lists the Grayhill part numbers included in the change notice 90B02SLT 90B03ST 90B02ST 90HBJ03PT 90HBJ02PRT 90HBW03PRT 90HBJ02PT 90HBW03PT 90HBW02PRT ...
Page 2
... MATERIAL CHANGE TEST REPORT Page 561 Hillgrove Ave., LaGrange, Illinois 60525-5997 USA Phone: 708-354-1040 Fax: 708-354-2820 http://www.grayhill.com 90 Series DIP Switches 1/18/10 Rev. A ...
Page 3
Introduction………………………………………………………………………… Subgroup 1-Thermal Shock, Mechanical Life, Dielectric Withstanding, CR, Operating Force………………………………………………………………….….. 3 3. Subgroup 2- Moisture Resistance, Insulation Resistance, Contact Resistance.…….. 3 4. Subgroup 3- Resistance to Wave Solder Process, CR……………………………… Subgroup 4- IR Reflow, ...
Page 4
... The purpose of this report is to provide information along with test data with respect to a change to be made in the plastic materials used in the construction of the Grayhill 90 Series DIP low profile switches. The change if from the PPA resin that is currently used 4/6 GF30 resin (UL94 V-0 rated). This change is being made due to obsolescence of the current material ...
Page 5
... Method 213 using test condition “E” (1,000 G’s, 0.5mS, half sine) for the test. Each switch was preset with half of the switches in the open position and half in the closed position. With all switch positions monitored in accordance with Method 310 of MIL- 202, no opening or closing of contacts in excess of 10 microseconds is allowed during the test period ...
Page 6
... Subgroup 8: 9.1. Resistance to IR Reflow Processing. -An additional hot air reflow test was conducted to determine the ability of the switches built using the new material to withstand temperature extremes by using a reflow profile at a higher temperature for longer duration. The reflow profile used had peak temperatures above 270 C for a duration of approximately 43 seconds ...
Page 7
... Grayhill 90 Series DIP switch products has been proven suitable material for use in place of the current material that is being discontinued. The new material is currently used in the Grayhill 94 series rotary DIP switches and has performed well in that product. ...