ZD20CDW TELEDYNE, ZD20CDW Datasheet

RELAY, OPTO ISOLATED, 60VDC

ZD20CDW

Manufacturer Part Number
ZD20CDW
Description
RELAY, OPTO ISOLATED, 60VDC
Manufacturer
TELEDYNE
Datasheet

Specifications of ZD20CDW

Control Voltage Type
DC
Input Voltage
2VDC To 3VDC
Load Current
1A
Load Voltage Range
0Vdc To 80Vdc
Control Voltage Dc Max
3VDC
Control Voltage Dc Min
2VDC
Current Rating
1A
Relay Terminals
Through Hole
© 2004 TELEDYNE RELAYS
FEATURES/BENEFITS
• Short-circuit protected
• Overload trip
• Low off-state leakage current
• Optical isolation
• Compact package
Part Number
ZD20CD*
SZD20CD*
*T, W level screening available
Input Current
Input Voltage @10mA
Must Turn-On
Must Turn-Off Current
Must Turn-Off Voltage
Reverse Polarity
Load Voltage Range
Output Current Rating (See Figure 6)
Leakage Current at Rated Voltage
Transient Blocking Voltage @25°C
Output Capacitance @25Vdc (25°C)
Output Voltage Drop @1A
On Resistance
Turn-On Time
Turn-Off Time
Trip Overload
Short Circuit Protection
(–55°C to +105°C ambient temperature
INPUT (CONTROL) SPECIFICATIONS
+IN (1)
INPUT
with
LEDs
–IN (3)
OUTPUT (LOAD) SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
unless otherwise specified)
Description
1A, 80 Vdc, short-circuit protected
up to 60 Vdc, solid-state relay for
through-hole mounting
1A, 80 Vdc, short-circuit protected up
to 60 Vdc, solid-state relay for surface
mount
(See Figure 7)
Min
Min
Isolation
Optical
–6
8
2
8
0
(800) 284-7007 • www.teledynerelays.com
FUNCTIONAL BLOCK DIAGRAM
Max
Max
0.55
0.55
100
100
600
0.8
1.0
2.0
1.0
20
80
20
60
3
Units
Units
Ohm
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
mA
mA
ms
ms
µA
µA
pF
A
A
Detection
Circuit
Figure 3
*Shorted internally
**Series resistor required to limit input current to 20mA maximum
Switching
MECHANICAL SPECIFICATIONS
Circuit
TYPICAL WIRING DIAGRAM
Rs
**
*
1
2
3
Figure 1
Figure 2
1A, 80 Vdc Optically Isolated
Output Switch
(MOSFET)
with Current
Sense
ZD20CD Series
Short-Circuit Protected
6
5
4
*
LOAD
LOAD
+OUT (6)
–OUT (4)
2DSZD20CD Rev --
ZD Page 1

Related parts for ZD20CDW

ZD20CDW Summary of contents

Page 1

... Ohm 2 1 *Shorted internally **Series resistor required to limit input current to 20mA maximum 60 Vdc FUNCTIONAL BLOCK DIAGRAM Detection Switching Circuit Circuit Figure 3 (800) 284-7007 • www.teledynerelays.com ZD20CD Series 1A, 80 Vdc Optically Isolated Short-Circuit Protected Figure LOAD LOAD Figure 2 +OUT (6) Output Switch (MOSFET) ...

Page 2

... Vdc maximum. ZD20CD series relays, the wave-solder or solder pot operations are limited to +260°C maximum for 10 seconds, maximum. series relays heating or convection heating systems, the component temperature is limited to +235°C maximum for 10 seconds maximum. © 2004 TELEDYNE RELAYS 2DSZD20CD Rev -- ...