G5V-1 12DC Omron, G5V-1 12DC Datasheet - Page 2

RELAY, PCB, SPCO, 12VDC

G5V-1 12DC

Manufacturer Part Number
G5V-1 12DC
Description
RELAY, PCB, SPCO, 12VDC
Manufacturer
Omron
Datasheet

Specifications of G5V-1 12DC

Coil Type
DC Coil, Sensitive
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
24V
Coil Voltage Vdc Nom
12V
Coil Current
12.5mA
Coil Resistance
960ohm
Coil Power Cont
150mW
Contact Configuration
SPCO
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
G5V-1
Note:
Note:
Note:
UL1950 (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR31928)
Load
Rated load
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value)
(See note.)
Contact resistance (See note 1.)
Operate time (See note 2.)
Release time (See note 2.)
Max. operating frequency
Insulation resistance (See note 2.)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
G5V-1
Approved Standards
Contact Ratings
Characteristics
Model
P level:
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 100 Ω . This value
may vary depending on the operating environment. Always double-check relay suitability under actual operating conditions.
The values here are initial values.
1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
2. Values in parantheses are actual values.
3. The insulation resistance was measured with a 500-VDC megohmmeter between coil and contacts and a 250-VDC megohm-
meter between contacts with the same polarity applied to the same parts as those used for checking the dielectric strength.
λ
60
SPDT
= 0.1 x 10
Contact form
–6
/operation
3 to 24 VDC
Coil ratings
Resistive load (cos φ = 1)
0.5 A at 125 VAC; 1 A at 24 VDC
Ag + Au-Alloy
2 A
125 VAC, 60 VDC
1 A
62.5 VA, 30 W
1 mA at 5 VDC
100 m Ω max.
5 ms max. (approx. 2.5 ms)
5 ms max. (approx. 0.9 ms)
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 M Ω min. (at 500 VDC between coil and contacts, at 250 VDC between contacts of same
polarity.)
1,000 VAC, 50/60 Hz for 1 min between coil and contacts
400 VAC, 50/60 Hz for 1 min between contacts of same polarity
1,500 V (10 x 160 µs) between coil and contacts (conforms to FCC Part 68)
Destruction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 100 m/s
Mechanical: 5,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (under rated load, at 1,800 operations/hr)
Operating: − 40°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 2 g
0.5 A, 125 VAC (general use)
0.3 A, 110 VDC (resistive load)
1 A, 30 VDC (resistive load)
2
2
Contact ratings
G5V-1
47