G5LE-1VD 12DC Omron, G5LE-1VD 12DC Datasheet - Page 2

RELAY, 10A, SPDT, 12VDC, VDE

G5LE-1VD 12DC

Manufacturer Part Number
G5LE-1VD 12DC
Description
RELAY, 10A, SPDT, 12VDC, VDE
Manufacturer
Omron
Datasheet

Specifications of G5LE-1VD 12DC

Relay Type
Power
Coil Voltage Vdc Nom
12V
Contact Current Max
10A
Contact Voltage Ac Nom
120V
Contact Voltage Dc Nom
30V
Coil Resistance
360ohm
Coil Type
DC
Coil Current
33.3mA
Nom Operating
RoHS Compliant
Contact Configuration
SPDT
Rohs Compliant
Yes
G5LE
Specifications
400-mW Type
Note:
360-mW Type
Note:
Note:
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Load
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value)
Contact resistance
Operate time
Release time
Max. switching frequency
Insulation resistance
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Coil Ratings
Contact Ratings
Characteristics
The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
P level: λ 60 = 0.1 x 10
–6
operations
Resistive load (cos φ = 1)
10 A at 120 VAC; 8 A at 30 VDC
10 A
250 VAC, 125 VDC (30 VDC when UL/CSA standard is applied)
AC: 10 A; DC: 8 A
1,200 VA, 240 W
100 mA at 5 VDC
100 m Ω max.
10 ms max.
5 ms max.
Mechanical: 18,000 operations/hr
Electrical:
100 M Ω min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
4,500 V (1.2 50 µs) between coil and contacts
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 100 m/s
Mechanical: 10,000,000 operations min. (at 18,000 operations/hr)
Electrical:
Operating: − 25°C to 85°C (with no icing)
Operating: 5% to 85%
Approx. 12 g
5 VDC
79.4 mA
63 Ω
75% max. of rated voltage
10% min. of rated voltage
170% of rated voltage at 23°C
Approx. 400 mW
5 VDC
72 mA
70 Ω
75% max. of rated voltage
10% min. of rated voltage
170% of rated voltage (at 23°C)
Approx. 360 mW
1,800 operations/hr at rated load
100,000 operations min. (at 1,800 operations/hr)
2
2
9 VDC
45 mA
200 Ω
9 VDC
40 mA
225 Ω
12 VDC
33.3 mA
360 Ω
12 VDC
30 mA
400 Ω
24 VDC
16.7 mA
1,440 Ω
24 VDC
15 mA
1,600 Ω
48 VDC
8.33 mA
5,760 Ω
48 VDC
7.5 mA
6,400 Ω
G5LE
185

Related parts for G5LE-1VD 12DC