G2RL-1A-E-CV DC12 Omron, G2RL-1A-E-CV DC12 Datasheet - Page 2

RELAY, PCB, SPST-NO, 12VDC, 16A

G2RL-1A-E-CV DC12

Manufacturer Part Number
G2RL-1A-E-CV DC12
Description
RELAY, PCB, SPST-NO, 12VDC, 16A
Manufacturer
Omron
Datasheet

Specifications of G2RL-1A-E-CV DC12

Relay Type
Power
Coil Voltage Vdc Nom
12V
Contact Current Max
16A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
24V
Coil Resistance
360ohm
Coil Type
DC Coil, Sensitive
Coil Current
20.8mA
Contact Configuration
SPST-NO
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
G2RL
Coil Rating
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Ambient Temperature
vs Rated Carry Current
Insulation
Note: Values in the above table are the initial values.
Other Data
Note: Values in the above table are the initial values.
2
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Coil insulation system
according to UL
Number of poles
Dielectric strength
Impulse withstand voltage
Insulation resistance
Creepage distance
Clearance distance
Insulation material group
Insulation to IEC 60664-1
Type of insulation
coil-contact circuit
Type of insulation
open contact circuit
Rated insulation voltage
Pollution degree
Rated voltage system
Over voltage category
RoHs directive 2002/95/EC
Flammability class according to UL94
Operate(set) time
Release(reset) time
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Category of protection (IEC 61810)
Weight
G2RL-1A-H, G2RL-1-H
G2RL-1A-E, G2RL-1-E
G2RL-2A, G2RL-2
Ambient temperature (°C)
G2RL-1A, G2RL-1
5 VDC
80.0 mA
62.5Ω
70% max. of the rated voltage
10% min. of the rated voltage
180% of rated voltage (at 23°C)
Approx.400 mW
Class F
1 pole
5,000 VAC, 1 min between coil and
contacts
1,000 VAC, 1 min between contacts
of same polarity
10 kV(1.2X50µs) between coil and contact
1,000 MΩ min. (at 500 VDC)
10 mm MIN.
10 mm MIN.
IIIa
Reinforced
Functional
250 V
3 (Flux protection), 2(Fully sealed)
250 V (Flux protection), 400 V (Fully sealed)
III
12 VDC
33.3 mA
360Ω
Standard models
Ambient Temperature
vs Maximum Coil Voltage
Note: The maximum coil voltage refers
to the maximum value in a varying
range of operating power voltage,
not a continuous voltage.
Standard/High-capacity/High-sensitivity models
Compliant
V-0
15 ms max.
5 ms max.
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 100 m/s
Operating: -40°C to 85°C (with no icing)
Storage:
Operating: 5% to 85%
RT II(Flux protection), RT III(Fully sealed)
Approx. 12g
24 VDC
16.7 mA
1,440Ω
Standard models
Ambient temperature (°C)
-55°C to 85°C (with no icing)
2 pole
5,000 VAC, 1 min between coil and
contacts
2,500 VAC, 1 min between contacts
of different polarity
1,000 VAC, 1 min between contacts
of same polarity
48 VDC
Approx.
8.96 mA
5,358Ω
430 mW
2
(approx. 10G)
2
(approx. 100G)
85
85
5 VDC
80.0 mA
62.5Ω
Approx.400 mW
High-capacity models
12 VDC
33.3 mA
360Ω
1 pole
5,000 VAC, 1 min between coil and
contacts
1,000 VAC, 1 min between contacts
of same polarity
High-capacity models
24 VDC
16.7 mA
1,440Ω
48 VDC
8.96 mA
5,358Ω
Approx.
430 mW
5 VDC
50.0 mA
100Ω
75% max. of the rated voltage
Approx. 250 mW
1 pole
5,000 VAC, 1 min between coil and
contacts
1,000 VAC, 1 min between contacts
of same polarity
3
250 V
High-sensitivity models
High-sensitivity models
12 VDC
576Ω
20.8 mA
24 VDC
10.42 mA
2,304Ω
G2RL