G2R-1A 12DC Omron, G2R-1A 12DC Datasheet - Page 5

RELAY, 10A, SPST-NO, 12VDC

G2R-1A 12DC

Manufacturer Part Number
G2R-1A 12DC
Description
RELAY, 10A, SPST-NO, 12VDC
Manufacturer
Omron
Datasheet

Specifications of G2R-1A 12DC

Relay Type
General Purpose
Coil Voltage Vdc Nom
12V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
275ohm
Coil Type
DC
Coil Current
43.6mA
Nom
RoHS Compliant
Contact Configuration
SPST-NO
Rohs Compliant
Yes
G2R
Standard Relays
Note:
Double-winding Latching Relays
Note:
Contact resistance
Operate (set) time
Release (reset) time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Contact resistance
Set time
Reset time
Min. set/reset signal width
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Characteristics
Values in the above table are the initial values.
Values in the above table are the initial values.
Item
Item
30 m Ω max. (high-capacity type: 100 m Ω max.)
15 ms max.
AC: 10 ms max.; DC: 5 ms max.
Mechanical: 18,000 operations/hr
Electrical:
1,000 M Ω min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 200 m/s
Mechanical: AC coil: 10,000,000 operations min.;
Electrical:
Operating: − 40°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 17 g
30 m Ω max.
20 ms max.
20 ms max.
30 ms max.
Mechanical:18,000 operations/hr
Electrical:
1,000 M Ω min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts
1,000 VAC, 50/60 Hz for 1 min between contacts
of same pole;
1,000 VAC, 50/60 Hz for 1 min between set and
reset coil
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: Set: 500 m/s
Reset:
Mechanical: 10,000,000 operations min (at 18,000 operations/hr)
Electrical:
Operating: − 40°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 17 g (Quick-connect type: approx. 20 g)
1,800 operations/hr (under rated load)
100,000 operations min. (at 1,800 operations/hr under rated load)
100 m/s
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load)
1,800 operations/hr (under rated load)
2
2
1 pole
1 pole
2
when energized; 100m/s
(approx. 10G)
2
(approx. 100G)
2
(approx. 50G); 200m/s
2
when no energized
2
50 m Ω max.
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts
3,000 VAC, 50/60 Hz for 1 min between contacts
of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
50 m Ω max.
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts
3,000 VAC, 50/60 Hz for 1 min between contacts
of different poles
1,000 VAC, 50/60 Hz for 1 min between contacts
of same pole
1,000 VAC, 50/60 Hz for 1 min between set and
reset coil
(approx. 20G)
2 poles
2 poles
G2R
209