62.82.9.024.0000 FINDER, 62.82.9.024.0000 Datasheet

RELAY, DPCO, 24VDC

62.82.9.024.0000

Manufacturer Part Number
62.82.9.024.0000
Description
RELAY, DPCO, 24VDC
Manufacturer
FINDER
Datasheet

Specifications of 62.82.9.024.0000

Relay Type
Power
Coil Voltage Vdc Nom
24V
Contact Current Max
30A
Contact Voltage Ac Nom
250V
Coil Resistance
445ohm
Coil Type
DC Coil
Coil Current
54mA
Nom Operating Power
1.3W
Relay Mounting
Flange
Contact Configuration
DPCO
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
8
62.22
22.2
38.2
Printed circuit mount
16 A Power relay
Features
* Distance between contacts ≥ 3 mm
** With the AgSnO
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated voltage/Maximum switching voltage V AC
Rated load AC1
Rated load AC15 (230 V AC)
Motor rating (230/400 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals (according to type)
2 & 3 Pole changeover contacts
or NO (
AC coils & DC coils
Reinforced insulation between coil and
contacts according to EN 60335-1,
with 6 mm clearance & 8 mm creepage
distance
SELV coil-contact separator option
Cadmium Free contact material options
8
(EN 60730-1).
peak current is 120 A - 5 ms (NO contact).
8
62.23
11.1
38.2
3 mm contact gap)
8
2
8.65 7.6 8.3
N
material the maximum
)
35.8
5.5 5.75
V AC (50/60 Hz)
VA (50 Hz)/W
62.2x-0300
8.65 7.6 8.3 11.25
mW (V/mA)
35.8
AC/DC
AC/DC
cycles
cycles
V DC
V AC
kW
AC
DC
VA
VA
ms
°C
A
A
2 & 3 pole changeover contact
PCB mount
Copper side view
A1
12 14
1
11
2 CO (DPDT)
8
12
14
11
A1
7
4
A
1
4
7
A
0.8/—
62.22
22.2
38.2
32
34
31
A2
B
10 · 10
62.22 / 62.23
32 34
3 6
3
6
9
B
0.8 U
0.2 U
1,000 (10/10)
8
31
(0.8…1.1)U
(0.8…1.1)U
9
16/0.6/0.4
A2
–40…+70
100 · 10
16/30**
250/400
2.2/1.3
AgCdO
10/10
4,000
1,500
5.6
5.8
7.6
8.8
8
750
N
N
RT I
6
/0.6 U
/0.1 U
/30 · 10
6
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
Copper side view
12 14 22 24 32 34
A1
3
1
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
3 CO (3PDT)
N
N
11
7
12
14
N
N
8
11
A1
4
0.8/1.5
1
4
7
A
6
A
11.1
62.23
2 5
22
24
21
38.2
21
8
11.1
2
5
8
32
34
31
A2
B
3 6
3
6
9
B
62 Series - Power relays 16 A
8
31
9
A2
5.6
5.8
8
7.6
8.8
2 NO (DPST-NO), ≥ 3 mm* 3 NO (3PST-NO), ≥ 3 mm*
2 & 3 pole normally open contact
(≥ 3 mm contact gap)
PCB mount
A1
Copper side view
11
62.22 - 0300
7
14
8
14
11
A1
4
62.22-0300 / 62.23-0300
4
7
A
A
0.8/—
22.2
38.2
34
31
A2
B
10 · 10
6
9
B
8
0.8 U
0.2 U
31
1,000 (10/10)
(0.85…1.1)U
(0.85…1.1)U
9
34
6
A2
16/1.1/0.7
–40…+50
250/400
100 · 10
16/30**
AgCdO
11.4
7.6
8.8
8
4,000
2,500
20/4
750
3/3
N
N
RT I
6
/0.6 U
/0.1 U
/30 · 10
6
A1
Copper side view
3
11
62.23 - 0300
7
14
8
14
11
N
N
A1
N
N
4
0.8/1.5
A
4
7
A
6
11.1
24
21
38.2
21
8
24
11.1
5
8
5
34
31
A2
B
B
6
9
8
31
9
34
6
A2
11.4
7.6
8.8
8
95
62

Related parts for 62.82.9.024.0000

62.82.9.024.0000 Summary of contents

Page 1

Features Printed circuit mount 16 A Power relay 2 & 3 Pole changeover contacts • contact gap) ≥ AC coils & DC coils • Reinforced insulation between coil and • contacts according to EN 60335-1, ...

Page 2

Features Plug-in mount/Faston 187 16 A Power relay Plug-in (92 series sockets) or • Faston 187 (4.8x0.5 mm) with optional mounting adaptors 2 & 3 Pole changeover contacts • contact gap) ≥ AC coils & ...

Page 3

Features Flange mount/Faston 250 16 A Power relay Faston 250 (6.3x0.8 mm) termination • Flange or optional mounting adaptors 2 & 3 Pole changeover contacts • contact gap) ≥ AC coils & DC coils • ...

Page 4

... Top 35 mm rail mount Lockable test button and mechanical flag indicator (0040) The dual-purpose Finder test button can be used in two ways: Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state ...

Page 5

Technical data Insulation Insulation according to EN 61810-1 ed. 2 Insulation between coil and contacts (1.2/50 µs) Dielectric strength between open contacts Dielectric strength between adjacent contacts Conducted disturbance immunity Burst (5...50)ns, 5 kHz Surge (1.2/50 ...

Page 6

Coil specifications DC version data Nominal Coil Operating range voltage code min 9.006 4.8 12 9.012 9.6 9.024 24 19.2 48 9.048 38.4 60 9.060 48 110 9.110 88 121 125 9.125 100 ...

Page 7

Accessories Mounting adaptor for types 62.3x and 62.8x.xxxx.xxx9 (M4) 47,2 062.10 47,2 M4 062.10 Flange mounting adaptor for types 62.3x and 62.8x.xxxx.xxx9 41 062.60 52.3 062.60 Sheet of marker tags for 62 series relays, plastic, 72 tags, 6x12 mm 060.72 ...

Page 8

Screw terminal (Box clamp) socket panel rail (EN 50022) mount For relay type Accessories Metal retaining clip (supplied with socket - packaging code SMA) 92.03 Identification tag Approvals Modules (see table below) (according to type): Timer modules ...

Page 9

PCB socket For relay type Accessories Metal retaining clip (supplied with socket - packaging code SMA) Technical data 92.13 Rated values Approvals Dielectric strength (according to type): Ambient temperature ...