P2CF-11 Omron, P2CF-11 Datasheet - Page 15

11 PIN Socket

P2CF-11

Manufacturer Part Number
P2CF-11
Description
11 PIN Socket
Manufacturer
Omron
Type
Socketr
Datasheets

Specifications of P2CF-11

Number Of Positions
11
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Accessory Type
Socket
Rohs Compliant
Yes
Associated Relay Series
H5CL
Number Of Poles
11
Mounting Style
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
Multiple Series
For Use With
Z2998 - RELAY TIMER DGTL SPDT 100/240VACZ2366 - RELAY REPEAT CYCLE ANLG 30HRSZ997 - RELAY TIMER ANALOG 24VDC/ACZ2358 - RELAY REPEAT CYCLE ANLG 30HRSZ876 - RELAY TIMER DPDT ANALOG 120\240V
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
P2CF11
Z884
■ Ratings
Note: 1. A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model.
■ Characteristics
Note: Refer to the Life-test Curve.
Rated supply voltage (See notes 1 and 2.) 100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz), 24 VAC/VDC (50/60 Hz), 48 VDC,
Operating voltage range
No-voltage input (See note 3.)
Power consumption
Control outputs
Accuracy of operating
time
Setting error
Operation start voltage
Influence of voltage
Influence of temperature ±1% FS max. (±1% FS ±10 ms max. in ranges of 0.6 and 1.2 s)
Insulation resistance
Dielectric strength
Impulse withstand
voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
EMC
Case color
Degree of protection
Weight
2. Do not use an inverter output as the power supply. Refer to Safety Precautions for All Timers for details.
3. For contact input, use contacts which can adequately switch 1 mA at 5 V.
http://www.ia.omron.com/
±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 0.6 and 1.2 s)
±5% FS ±50 ms max.
30% max. of rated voltage
±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 0.6 and 1.2 s)
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
3 kV (between power terminals) for 100 to 120 VAC, 200 to 240 VAC, 100 to 125 VDC;
1 kV for 24 VAC/DC, 48 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 120 VAC, 200 to
240 VAC, 100 to 125 VDC;
1.5 kV for 24 VAC/DC, 48 VDC
±1.5 kV (between power terminals) and ±600 V (between input terminals), square-wave noise by noise simulator
(pulse width: 100 ns/1 μs, 1-ns rise); ±1 kV (between power terminals) for 48 VDC
Malfunction: 8 kV, Destruction:15 kV
Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions
Destruction: 980 m/s
Malfunction: 98 m/s
Operating:
Storage:
Operating:
Mechanical: 10 million operations min. (under no load at 1,200 operations/h)
Electrical:
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900±5 MHz) (level 3)
Immunity Conducted Disturbance: IEC61000-4-6:
Immunity Burst:
Immunity Surge:
Light Gray (Munsell 5Y7/1)
IP40 (panel surface)
Approx. 120 g
−10°C to 55°C (with no icing),
−25°C to 65°C (with no icing)
35% to 85%
100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h) (See note)
100 to 125 VDC
85% to 110% of rated supply voltage
ON-impedance:
ON residual voltage: 1 V max.
OFF impedance:
100 to 120 VAC: approx. 0.23 VA (0.22 W) at 120 VAC
200 to 240 VAC: approx. 0.35 VA (0.3 W) at 240 VAC
24 VAC/DC:
48 VDC:
100 to 125 VDC: approx. 0.5 W at 125 VDC
Contact output: 5 A at 250 VAC/30 VDC, resistive load (cosφ = 1)
2
2
three times each in six directions
three times each in six directions
EN61812-1
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61812-1
IEC61000-4-2:
IEC61000-4-4:
IEC61000-4-5:
approx. 0.17 VA (0.15 W) at 24 VAC
approx. 0.1 W at 24 VDC
approx. 0.18 W at 48 VDC
1 kΩ max.
500 kΩ min.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
6 kV contact discharge (level 3)
8 kV air discharge (level 3)
IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
10 V (0.15 to 80 MHz) (level 3)
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
1 kV line to line (level 3)
2 kV line to ground (level 3)
H3CR-H