6000-210011-FEC Storm Interface, 6000-210011-FEC Datasheet

KEYPAD, MATRIX OUTPUT

6000-210011-FEC

Manufacturer Part Number
6000-210011-FEC
Description
KEYPAD, MATRIX OUTPUT
Manufacturer
Storm Interface
Datasheet

Specifications of 6000-210011-FEC

Keypad Array
3 X 4
Contact Voltage Dc Nom
24V
Keypad Output
Matrix
Panel Cutout Width
109.5mm
Panel Cutout Height
118.5mm
Colour
Black Legend On White Background
No. Of Keys
16
Svhc
No SVHC
Contact Current Max
50mA
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Numeric data entry
in exposed public environments
• Rugged, reliable and
• Vandal resistant
• Weather resistant (IP65)
• Large buttons for clarity
• Permanent, high contrast,
• Raised tactile symbols on coloured
• Raised "home pip" on the "5" key
UK Email: sales@storm-interface.com Tel: +44 (0)1895 431421
USA Email: sales.usa@storm-keypads.com Tel: +1 (630) 469 2981
responsive data entry
(20J BS EN 60068-2-75: 1997)
and ease of use
laser engraved keytop graphics
function keys
6000 Series Keypads
• 4 row x 4 column matrix
• Optional USB or PS2 encoded
• Optional PS2 or USB connection
• Suitable for use by those with
• Overall dimensions:
circuit format
interface circuit (enclosed in water
resistant pod)
cable (supplied separately)
mobility or sensory impairment
124.0 mm x 118.5 mm x 17.5 mm
(excluding interface pod
on back face)
www.storm-interface.com
protected by international patents and design
Storm Interface products include technology
registration. All rights reserved.

Related parts for 6000-210011-FEC

6000-210011-FEC Summary of contents

Page 1

... Raised tactile symbols on coloured function keys • Raised "home pip" on the "5" key UK Email: sales@storm-interface.com Tel: +44 (0)1895 431421 USA Email: sales.usa@storm-keypads.com Tel: +1 (630) 469 2981 6000 Series Keypads • 4 row x 4 column matrix circuit format • Optional USB or PS2 encoded interface circuit (enclosed in water resistant pod) • ...

Page 2

... Series keypad for public environments UK Keypad Layout USA Keypad Layout Function Key Colours CANCEL Red ? Blue CLEAR Yellow ENTER Green Matrix Keypad Connections Row 1 Row 1 Row 1 Row 1 Column 1 Column 2 Column 3 Column 4 Row 2 Row 2 Row 2 Row 2 Column 1 Column 2 Column 3 Column 4 Row 3 ...

Page 3

... Series keypad for public environments Application / Engineering Manual UK OFFICE 14 Bentinck Court Bentinck Road West Drayton UB7 7RQ ENGLAND Tel +44 (1895) 431421 email: sales@keymat.com 6000 Series Application/Engineering Manual Version 1.01 Feb 2004 Page ...

Page 4

... Whilst every effort is made to ensure the information, data and illustrations are correct at the time of publication, Keymat Technology Ltd. are not responsible for any errors or omissions contained within this document. 6000 Series keypad for public environments Application / Engineering Manual 6000 Series Application/Engineering Manual Version 1.01 Feb 2004 Page Page 3 4 ...

Page 5

... Whilst every effort is made to ensure the information, data and illustrations are correct at the time of publication, Keymat Technology Ltd. are not responsible for any errors or omissions contained within this document. 6000 Series keypad for public environments Application / Engineering Manual 6000 Series Application/Engineering Manual Version 1.01 Feb 2004 Page ...

Page 6

... Whilst every effort is made to ensure the information, data and illustrations are correct at the time of publication, Keymat Technology Ltd. are not responsible for any errors or omissions contained within this document. 6000 Series keypad for public environments Application / Engineering Manual Matrix Output PS2 / USB Output Available as an option 6000 Series Application/Engineering Manual Version 1.01 Feb 2004 Page “Encryption Ready” Not Available ...

Page 7

... Section 3. Ratings and Performance The 6000 Series keypad range is designed to meet the following requirements. Validation is by in-house test and additional third party assessment by an accredited test house, where appropriate. Storm 6000 Series keypads are a UL Recognized Component. Electrical EMC Emissions EMC Immunity to ESD ...

Page 8

... The 6000 Series keypad range is designed to meet the requirements of existing and forthcoming Disability Access Requirements. As international standards requirements are many and varied (although with some common themes for ATM Keypads), we have chosen the ADAAG requirements to illustrate compliance in the table below Key Characteristics Key surfaces shall be raised above the surrounding surface by 1/25 inch (1 mm) mini- mum ...

Page 9

... Section 4. Connectors and Connections - Matrix Output The 6000 Series matrix keypad is supplied without a cable so that the user can select the correct cable length. Switches provide a momentary contact between designated connector pins. Pins are to suit Molex KK Type 0.1” Pitch Headers. The Connector Details below shows the orientation and position of the connector. ...

Page 10

... Section 4. Connectors and Connections - PS2/USB Output The 6000 Series encoded keypad is supplied without a cable so that the user can select the correct cable length and connector type to suit their application. Cables are offered as separately purchased options, or alternatively the user can source their own cable to suit the application. The pinout details for the connectors are shown on the following page ...

Page 11

... Whilst every effort is made to ensure the information, data and illustrations are correct at the time of publication, Keymat Technology Ltd. are not responsible for any errors or omissions contained within this document. 6000 Series keypad for public environments Application / Engineering Manual 6000 Series Application/Engineering Manual Version 1.01 Feb 2004 Page ...

Page 12

... Whilst every effort is made to ensure the information, data and illustrations are correct at the time of publication, Keymat Technology Ltd. are not responsible for any errors or omissions contained within this document. 6000 Series keypad for public environments Application / Engineering Manual 6000 Series Application/Engineering Manual Version 1.01 Feb 2004 Page 1.2 Then fit screws (4 positions) ...

Page 13

... Section 5. Installation The 6000 Series keypad is designed to be secured with 6 panel mount clips and locknuts. The gasket positioned between keypad and fixing panel prior to installation. Ensure that a suitable panel material is used to support the keypad. This must provide sufficient rigidity where sealing is required. (e.g. 1.6mm to 2.0mm steel). ...

Page 14

... Whilst every effort is made to ensure the information, data and illustrations are correct at the time of publication, Keymat Technology Ltd. are not responsible for any errors or omissions contained within this document. 6000 Series keypad for public environments Application / Engineering Manual 6000 Series Application/Engineering Manual Version 1.01 Feb 2004 Page ...

Page 15

... Whilst every effort is made to ensure the information, data and illustrations are correct at the time of publication, Keymat Technology Ltd. are not responsible for any errors or omissions contained within this document. 6000 Series keypad for public environments Application / Engineering Manual Series Encoder , for fixing and connection details) 6000 Series Application/Engineering Manual Version 1.01 Feb 2004 Page ...

Page 16

... Series keypad for public environments Application / Engineering Manual Other layouts are possible –see below. Contact your Storm distributor for availability. Alternative Layout - 13 Key Alternative Layout - 15 Key 6000 Series Application/Engineering Manual Version 1.01 Feb 2004 Page ...

Page 17

... Whilst every effort is made to ensure the information, data and illustrations are correct at the time of publication, Keymat Technology Ltd. are not responsible for any errors or omissions contained within this document. 6000 Series keypad for public environments Application / Engineering Manual 6000 Series Application/Engineering Manual Version 1.01 Feb 2004 Page ...

Page 18

... PRS Black TUV Black WXY Black Blue * 7C 55 Black Black Black Red with 5A 28 CANCEL raised Cross NOT USED 6000 Series Application/Engineering Manual Version 1.01 Feb 2004 Page USA Layout ASCII PC/AT Code USB Code (Code Set 2) Code ...

Related keywords