B57045K103K EPCOS Inc, B57045K103K Datasheet - Page 10

THERMISTOR NTC 10K OHM 10% PROBE

B57045K103K

Manufacturer Part Number
B57045K103K
Description
THERMISTOR NTC 10K OHM 10% PROBE
Manufacturer
EPCOS Inc
Series
B57045r
Type
NTCr
Datasheet

Specifications of B57045K103K

Resistance In Ohms @ 25°c
10K
Resistance Tolerance
±10%
B Value Tolerance
±3%
B25/100
4300K
Operating Temperature
-55°C ~ 125°C
Power - Max
450mW
Lead Length
1.18" (30.00mm)
Mounting Type
Chassis Mount
Package / Case
Non Standard, Threaded Stud
Operating Temperature Min
55°C
Operating Temperature Max
125°C
Resistance
10 KOhms
Tolerance
10 %
Termination Style
Radial
Operating Temperature Range
- 55 C to + 125 C
Power Rating
450 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
B0/50
-
B25/50
-
B25/75
-
B25/85
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
495-2138
B57045K 103K
B57045K0103K000
Mounting
Operation
This listing does not claim to be complete, but merely reflects the experience of EPCOS AG.
Please read Cautions and warnings and
Important notes at the end of this document.
Temperature measurement
Probe assemblies
Ensure that no thermo-mechanical stress occurs due to production processes (curing or
overmolding processes) when thermistors are sealed, potted or overmolded or during their
subsequent operation. The maximum temperature of the thermistor must not be exceeded.
Ensure that the materials used (sealing/potting compound and plastic material) are chemically
neutral.
Electrodes/contacts must not be scratched or damaged before/during/after the mounting
process.
Contacts and housing used for assembly with the thermistor must be clean before mounting.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of the thermistor. Be sure that surrounding parts and materials can
withstand the temperature.
Avoid contamination of the thermistor surface during processing.
The connections of sensors (e.g. cable end, wire end, plug terminal) may only be exposed to
an environment with normal atmospheric conditions.
Tensile forces on cables or leads must be avoided during mounting and operation.
Bending or twisting of cables or leads directly on the thermistor body is not permissible.
Avoid using chemical substances as mounting aids. It must be ensured that no water or other
liquids enter the NTC thermistors (e.g. through plug terminals). In particular, water based
substances (e.g. soap suds) must not be used as mounting aids for sensors.
Use thermistors only within the specified operating temperature range.
Use thermistors only within the specified power range.
Environmental conditions must not harm the thermistors. Only use the thermistors under
normal atmospheric conditions or within the specified conditions.
Contact of NTC thermistors with any liquids and solvents should be prevented. It must be
ensured that no water enters the NTC thermistors (e.g. through plug terminals). For
measurement purposes (checking the specified resistance vs. temperature), the component
must not be immersed in water but in suitable liquids (e.g. Galden).
Avoid dewing and condensation unless thermistor is specified for these conditions.
Bending or twisting of cables and/or wires is not permissible during operation of the sensor in
the application.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by malfunction.
Page 10 of 13
B57045K
K45

Related parts for B57045K103K