MLX90609EEA-N2 Melexis Inc, MLX90609EEA-N2 Datasheet
MLX90609EEA-N2
Specifications of MLX90609EEA-N2
Related parts for MLX90609EEA-N2
MLX90609EEA-N2 Summary of contents
Page 1
... EEPROM…). These types of applications need close cooperation between the customer and Melexis. Please contact Melexis in case you have such an application. Ordering Information Part No. Temperature Code MLX90609EEA-N2 E (-40° 85° C) MLX90609EEA-E2 E (-40° 85° C) MLX90609EEA-R2 E (-40° 85° C) Note: Other Full Scale Ranges can be provided ...
Page 2
Table of Contents 1. Maximum Ratings ............................................................................................................ 3 2. Pin Definitions and Descriptions ...................................................................................... 4 3. MLX90609 General Electrical Specifications ................................................................... 5 4. MLX90609 Sensor Specific Specifications....................................................................... 6 5. Detailed Description......................................................................................................... 8 5.1 The Working Principle ................................................................................................. 8 5.2 Communication ...
Page 3
Maximum Ratings MLX90609 operates without failure, for 6500 hours with a certain temperature profile in the 40°C to +85ºC range. The MLX90609 meets the following maximum ratings over the entire operating temperature range and supply voltage range unless otherwise ...
Page 4
Pin Definitions and Descriptions Group SS 390109060901 Rev 010 MLX90609 Angular Rate Sensor (Standard version) Figure 2-1. MLX90609 pin-out Pin Name Table 2. MLX90609 Pin description Page Function Data Sheet November/08 ...
Page 5
MLX90609 General Electrical Specifications DC Operating Parameters TA = -40° 85° C, VDD = 4.75V to 5.25V. Parameter. 390109060901 Rev 010 MLX90609 Angular Rate Sensor (Standard version) Symbol Test Conditions U OUT ,Ω max U ,Ω min ...
Page 6
MLX90609 Sensor Specific Specifications DC Operating Parameters T = -40° 85° C, VDD = 4.75V to 5.25V (unless otherwise specified) A Parameter 390109060901 Rev 010 MLX90609 Angular Rate Sensor (Standard version) Symbol Test Conditions ...
Page 7
Parameter Notes: 1. 3-5 times better performance can be obtained. Please contact Melexis. 2. These numbers are guaranteed by design and/or characterization. 3. The voltage reference should ideally not be loaded, as there is an internal ESD resistor of about ...
Page 8
Detailed Description 5.1 The Working Principle The MLX90609 is a Z-axis rate-sensing device, also called yaw-rate sensing. It produces an analog positive going output voltage for clockwise (CW) rotation around the axis normal to the package top, i.e., clockwise ...
Page 9
Communication with the MLX90609 through the SPI The MLX90609 has a serial communication interface compatible with Serial Peripheral Interface (SPI). Likewise SPI the Serial Interface of the MLX90609 specifies four signals: serial clock (SCLK); master data output, slave data ...
Page 10
Figure 5-2. Figure 5-3. Serial Exchange Sequence (the reading of the higher half of the answer) 390109060901 Rev 010 MLX90609 Angular Rate Sensor (Standard version) Serial Exchange Sequence (full answer reading) Page Data Sheet November/08 ...
Page 11
Parameter Limit Table 5. SPI Timing Characteristics (see Figure 5-4) 390109060901 Rev 010 MLX90609 Angular Rate Sensor (Standard version) Synchronous Data Timing Figure 5-4. Units Test Conditions/Comments Page Data Sheet November/08 ...
Page 12
Using of the ADC The MLX90609 has the unique feature of simultaneously delivering an analog and a digital output signal. The MLX90609 includes an internal 11-bit successive-approximation-register ADC with a sample- and-hold circuit and a programmable 2-channel analog multiplexer. ...
Page 13
ADC Instructions and Answers There are three SPI commands that are used to control embedded ADC of the MLX90609: STATR, ADCC and ADCR. • The Refusal Answer Every instruction sent to the MLX90609 has an answer. If the MLX90609 ...
Page 14
Reading the Digital Angular Rate or Temperature (suggested procedure) There is a recommended sequence below to obtain digital data from the ADC. Notes: - The bit with leftmost position should be shifted first. - Below “x” means any value: ...
Page 15
Applications Examples Figure 6-1. MLX90609 with The MLX90609 can simultaneously output analog and digital signals. The analog output signal can be fed to a microcontroller (µC) that contains an analog-to-digital converter. A multiplexer can be used to select between ...
Page 16
Figure 6-2. MLX90609 with If only an analog output signal is required, the MLX90609 doesn’t need to communicate through the SPI pins. All other pins continue to be used as described above. Figure 6-3. MLX90609 with If only a digital ...
Page 17
In order to adapt the MLX90609 for a 3.3V Microcontroller one can use the below schematic: Figure 6-4. Possible interfacing with 3.3V µC 390109060901 Rev 010 MLX90609 Angular Rate Sensor (Standard version) Page Data Sheet November/08 ...
Page 18
Standard Information Regarding Manufacturability of Melexis Products with Different Soldering Processes Our products are classified and qualified regarding soldering technology, solderability and moisture sensitivity level according to following test methods: Reflow Soldering SMD’s (Surface Mount Devices) IPC/JEDEC J-STD-020 Moisture/Reflow ...
Page 19
Package Information The MLX90609 is packaged pin JESD30C compliant Ceramic Quad Flat None leaded - CQFN32 -ceramic housing. The CQFN32 is commonly called CLCC32 or LCCC32. Note: All dimensions are given in mm (inch). Figure 9-1. ...
Page 20
Figure 9-3. MLX90609 Bottom View 10. Glossary of Terms Angular Rate Sensor A sensor that measures rotational velocity measured in degrees per second around its sensitive axis. Angular rate sensors are sometimes referred to as gyro or gyroscope. Bandwidth The ...
Page 21
Primary and Secondary Frame In vector notation the Coriolis force × Ω Coriolis Where m is the mass of the object, v its velocity and system. To create a Coriolis Force (F ...
Page 22
Disclaimer Devices sold by Melexis are covered by the warranty and patent indemnification provisions appearing in its Term of Sale. Melexis makes no warranty, express, statutory, implied description regarding the information set forth herein or regarding the ...