M22-LED230-G MOELLER, M22-LED230-G Datasheet - Page 100

INDICATOR, LED PANEL MNT, GREEN, 85V

M22-LED230-G

Manufacturer Part Number
M22-LED230-G
Description
INDICATOR, LED PANEL MNT, GREEN, 85V
Manufacturer
MOELLER
Datasheet

Specifications of M22-LED230-G

Forward Voltage
85V
Led Color
Green
Operating Temperature Range
-25°C To +70°C
Operating Temperature Min
-25°C
Forward Current If
5mA
Operating Temperature Max
70°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M22-LED230-G
Manufacturer:
MOELLER
Quantity:
6 000
B
Jumpers determine wiring sequence
Stack Lights
General
Standards
Degree of protection, IEC/EN 60529
Climatic proofing
Ambient temperature
Mounting position
Mechanical shock resistance according to
IEC 60068-2-27
Terminal Capacity
Contacts
Rated impulse withstand voltage
Rated insulation voltage
Overvoltage category / pollution degree
Enclosed
Shock duration 11 ms, half-sinusoidal
Solid
Stranded
4
3
BA15d ≤ 7 W
B8
2
5
moellerNA.com
N
0
1
0 5 4 3 2 1
U
U
imp
i
For Immediate Delivery call KMParts.com at (866) 595-9616
[mm
[mm
[V AC]
[˚C]
[V]
[g]
2
2
]
]
1...5 U
IP20 with SL-A acoustic indicator
60068-2-78; Damp heat, cyclical,
Damp heat, constant, to IEC
IP65 with SL-IP65 gasket;
e
to IEC 60068-2-30
SL Stack Lights
= 24 – 230 Vh/Hz
IEC/EN 60947
As required
0.75 – 2.5
0.5 – 2.5
- 25 / 50
module
> 15
4000
III / 3
250
5 =
4 =
3 =
2 =
1 =
ASI Base Module
General
Connection of the AS interface line
Addressing
Maximum total current
Power supply
Ambient temperature
Status LEDs on the circuit board
Profile
4
3
2
5
1
Built-in jumpers are used in stack light modules
to determine the wiring position.
The jumper of the bottom-most module should
be set to position 1; this is the supplied jumper
position for all modules.
When a second module is added on top of the
first, the jumper must be moved to position 2.
The jumper of the third module must be moved
to position 3, and so on.
A maximum of five modules may be added to a
stack light.
[mA]
[˚C]
AS interface error, AS interface master
Status. Output Q0/function module
Status. Output Q1/function module
Status. Output Q2/function module
AS interface power line: green
From AS interface line only
Screw terminal on the
Through AS interface
position 1: green
position 2: green
position 3: green
line connection
circuit board
failure: red
SL-B-ASI
-25 / 55
S-9.A.E
Technical Data
≤ 250
TITAN-CAT-NA-0807
Stack Lights

Related parts for M22-LED230-G