3RH19212FA22 SIEMENS, 3RH19212FA22 Datasheet - Page 54

AUXILIARY CONTACT, 2NO/2NC

3RH19212FA22

Manufacturer Part Number
3RH19212FA22
Description
AUXILIARY CONTACT, 2NO/2NC
Manufacturer
SIEMENS
Datasheet

Specifications of 3RH19212FA22

No. Of Poles
4
Contact Current Max
6A
Contact Voltage Ac Max
600V
Contact Voltage Dc Max
600V
Contact Current Rating
6A
Terminal Type
Cage Clamp
Switch Terminals
Cage Clamp
Approval Bodies
UL,
For Use With
3RT, 3RH Contactors And Contactor Relays
For 3RT, 3RH Contactors and Contactor Relays
Accessories for 3RT, 3RH contactors and
contactor relays
1) For connectable cross-sections, see Technical specifications of
2) As standard for 3RT10 54-1 contactor (55 kW).
3) Also fits on contactors S6 ... S12 with box terminals.
3RT19 5.-4G
3RT19 36-4EA2
3RT19 46-4EA1
Box terminal blocks
Covers
Sealable covers
3/124
contactors in Catalog LV 1 T.
Accessories and Spare Parts
Siemens LV 1 · 2006
For contactors
Size
S6
S10/S12
S2
S3
S6
S10/S12
S3
S6
S10/S12
S6
S10/S12
S00
S0 ... S12 3RT1. 2 ...
5)
Type
3RT1. 5
(3RB10 5)
3RT1. 6,
3RT1. 7
(3RB10 6)
3RT10 3
3RT10 4,
3RT14 4
3RT1. 5
3RT1. 6,
3RT1. 7
3RT10 4,
3RT14 4
3RT1. 5
3RT1. 6,
3RT1. 7
3RT1. 5
3RT1. 6,
3RT1. 7
3RT1. 1,
3RH1.
3RT1. 7
6)
6)
Version
For round and ribbon cables
Up to 70 mm²
Up to 120 mm²
Auxiliary conductor
connection for box terminal
Up to 240 mm²
With auxiliary conductor
connection
Terminal covers for box terminals
Additional touch protection for
fitting to box terminals
(2 units per contactor
required)
Length: 25 mm
Length: 30 mm
Terminal covers for cable lug and busbar connection
For maintaining the voltage
clearances and as touch
protection if box terminal is
removed
(2 units per contactor
required)
Length: 100 mm
Length: 120 mm
For rail cover between
contactor and 3RB10 overload
relay or wiring connector for
contactor assemblies
Length: 27 mm
Length: 42 mm
Sealable cover for preventing
manual operation
1 unit required per contactor
4)
2)
1)
4) Observe the note in Catalog LV 1 T, Technical specifications,
5) The 3RT19 66-4EA3 cover is required in addition for use in contactor
6) Exception: Contactors and contactor relays auxiliary switch block
DT
}
}
B
}
}
}
}
}
}
}
}
}
}
A
B
conductor cross-sections.
assemblies (reversing/wye delta).
mounted onto the front.
Order No.
3RT19 55-4G
3RT19 56-4G
3TX7 500-0A
3RT19 66-4G
3RT19 36-4EA2
3RT19 46-4EA2
3RT19 56-4EA2
3RT19 66-4EA2
3RT19 46-4EA1
3RT19 56-4EA1
3RT19 66-4EA1
3RT19 56-4EA3
3RT19 66-4EA3
3RT19 16-4MA10
3RT19 26-4MA10
* You can order this quantity or a multiple thereof.
3)
Price
per PU
PU
(UNIT,
SET, M)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
PS*
5 units
5 units
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
PG
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
Weight
per PU
approx.
kg
0.237
0.270
0.008
0.676
0.016
0.023
0.028
0.038
0.037
0.067
0.124
0.021
0.062
0.005
0.006

Related parts for 3RH19212FA22