3RH19112FA40 SIEMENS, 3RH19112FA40 Datasheet - Page 48

AUXILIARY CONTACT, 4NO

3RH19112FA40

Manufacturer Part Number
3RH19112FA40
Description
AUXILIARY CONTACT, 4NO
Manufacturer
SIEMENS
Datasheet

Specifications of 3RH19112FA40

No. Of Poles
4
Contact Current Max
6A
Contact Voltage Ac Max
600V
Contact Voltage Dc Max
600V
Contact Current Rating
6A
Terminal Type
Cage Clamp
Switch Terminals
Cage Clamp
Approval Bodies
UL, CSA,
For Use With
3RT, 3RH Contactors And Contactor Relays
For 3RT, 3RH Contactors and Contactor Relays
Accessories for 3RT, 3RH contactors and
contactor relays
1) Cannot be fitted onto coupling relays.
2) Not to be used for 3RT10 4. and 3RT13 4. contactors with U
3) In addition to these, no other auxiliary contacts are permitted.
3RT19 16-2C...
3RT19 16-2D...
3RT19 26-2C...
3RT19 26-2D...
3RT19 16.-2B.01
3RT19 26-2P...
3RT19 26-3A.31
Solid-state time-delay blocks with semiconductor output
OFF-delay devices
Pneumatic delay blocks,
terminal designation according to EN 50005
Mechanical latching blocks
3/118
Accessories and Spare Parts
Siemens LV 1 · 2006
For contactors
Type
Size S00
3RT1. 1,
3RH11
3RH14
3RT1. 1,
3RH11
3RH14
Sizes S0 ... S3
3RT10 2,
3RT10 3,
3RT10 4,
3RT13
3RT15
3RT10 2,
3RT10 3,
3RT10 4,
3RT13
3RT15
3RT1. 1,
3RT1. 2,
3RH1 ...-1BF40
3RT1. 1,
3RT1. 2,
3RH1 ...-1BM40
3RT1. 1 ... 3RT1. 4,
3RH1 ...-1BB40
3RT1. 2
Sizes S0 and S2
3RT1. 2,
3RT1. 3
2)
2)
1)
1)
Rated control supply
voltage U
V
For mounting onto the front of contactors
• ON-delay (varistor integrated)
24 ... 66 AC/DC
90 ... 240 AC/DC
• OFF-delay with auxiliary voltage (varistor integrated)
24 ... 66 AC/DC
90 ... 240 AC/DC
For mounting onto coil terminals on top of the contactors
• ON-delay (varistor integrated)
24 ... 66 AC/DC
90 ... 240 AC/DC
• OFF-delay with auxiliary voltage (varistor integrated)
24 ... 66 AC/DC
90 ... 240 AC/DC
110 AC/DC
220/230 AC/DC
24 DC
For mounting onto the front of size S0
Auxiliary contacts 1 NO and 1 NC
• ON-delay
• OFF-delay
For mounting on 1 contactor,
contactor remains in the energized state even after a voltage failure
24 AC/DC
110 AC/DC
230 AC/DC
s
s
ˆ 42 V.
Time setting
range t
s
0.05 ... 1
0.5 ... 10
5 ... 100
0.05 ... 1
0.5 ... 10
5 ... 100
0.05 ... 1
0.5 ... 10
5 ... 100
0.05 ... 1
0.5 ... 10
5 ... 100
0.05 ... 1
0.5 ... 10
5 ... 100
0.05 ... 1
0.5 ... 10
5 ... 100
0.05 ... 1
0.5 ... 10
5 ... 100
0.05 ... 1
0.5 ... 10
5 ... 100
0.1 ... 30
1 ... 60
0.1 ... 30
1 ... 60
DT
B
}
B
D
}
}
C
B
B
D
}
B
D
B
D
}
}
}
D
D
D
C
D
C
D
D
}
C
C
C
C
A
B
B
3)
Order No.
3RT19 16-2CG11
3RT19 16-2CG21
3RT19 16-2CG31
3RT19 16-2CH11
3RT19 16-2CH21
3RT19 16-2CH31
3RT19 16-2DG11
3RT19 16-2DG21
3RT19 16-2DG31
3RT19 16-2DH11
3RT19 16-2DH21
3RT19 16-2DH31
3RT19 26-2CG11
3RT19 26-2CG21
3RT19 26-2CG31
3RT19 26-2CH11
3RT19 26-2CH21
3RT19 26-2CH31
3RT19 26-2DG11
3RT19 26-2DG21
3RT19 26-2DG31
3RT19 26-2DH11
3RT19 26-2DH21
3RT19 26-2DH31
3RT19 16-2BK01
3RT19 16-2BL01
3RT19 16-2BE01
contactors
3RT19 26-2PA01
3RT19 26-2PA11
3RT19 26-2PR01
3RT19 26-2PR11
3RT19 26-3AB31
3RT19 26-3AF31
3RT19 26-3AP31
* You can order this quantity or a multiple thereof.
Price
per PU
PU
(UNIT,
SET, M)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
PS*
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
PG
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
Weight
per PU
approx.
kg
0.051
0.051
0.054
0.052
0.052
0.051
0.057
0.057
0.057
0.053
0.060
0.058
0.048
0.049
0.048
0.048
0.047
0.048
0.050
0.051
0.051
0.050
0.050
0.050
0.143
0.144
0.114
0.078
0.078
0.078
0.078
0.122
0.130
0.125

Related parts for 3RH19112FA40