SOM40100 CELDUC, SOM40100 Datasheet - Page 2
SOM40100
Manufacturer Part Number
SOM40100
Description
RELAY. 40A/12-60V/3.5-32V
Manufacturer
CELDUC
Datasheet
1.SOM40100.pdf
(5 pages)
Specifications of SOM40100
Load Voltage Max
60VDC
Load Current
40A
On State Resistance Max
30mohm
Isolation Voltage
2.5kV
Forward Current If
35mA
Svhc
No SVHC (18-Jun-2010)
Control Voltage Type
DC
Load Current Rms Max
40A
Relay Terminals
Screw
Rohs Compliant
Yes
Control Voltage Dc Max
32V
Control Voltage Dc Min
3.5V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Nom. Control voltage
Min. Control current
Control voltage range
Control current consumption
Releasing control voltage
Max. reverse control voltage
Input impedance
Nominal voltage
Voltage range
Non-repetitive peak voltage
Overvoltage protection
Max reverse voltage drop
(internal diode at OFF state)
Maximum nominal currents
Non-repetitive peak overload
current
Min. load current
Max. leakage current
Max. on-state resistance
Typ. output capacitance
Junction/case thermal
resistance per power element
Built-in heatsink thermal
resistance vertically mounted
Heatsink thermal time constant
Control inputs/power outputs
insulation voltage
Inputs/case insulation voltage
Outputs/case insulation voltage
Isolation resistance
Isolation capacitance
Maximum junction temperature
Storage ambient temperature
Operating ambient temperature
Max. case temperature
Ielk : Leakage current of the relay
Ie : User load nominal current
Utp : Relay max. non repetitive peak voltage
celduc
r
Ielk / Ie
0,8
0,6
0,4
0,2
1
0
Leakage current (Ielk) vs DC voltage (Ut)
e
0
l
CHARACTERISTIC
CHARACTERISTIC
a
10 20
i
s
®
30 40
50
( =U emax)
U t max
PRELIMINARY DATA
60 70
80 90 100
Ucoffmax
Ut
Ielk max
-Ucmax
LABEL
Ucnom
LABEL
Uenom
Id max
RDSon
Ie max
Tjmax
Rthra
Icmin
Iemin
Tthra
Tamb
Rthjc
Uimp
Uimp
Uimp
Cout
Tstg
Utp
Rin
Rio
Cio
-Ut
Uc
D1
Tc
Ic
U t p
Ue
Ut (V)
Utmax : Max. nominal voltage of the relay
Uto : Possible overvoltage above Utmax
Utn = Ue : User DC power supply voltage
CONTROL INPUT CHARACTERISTICS
Resistive
32 – 35mADC (for control voltage range)
POWER OUTPUT CHARACTERISTICS
40A
PROTECTION CHARACTERISTICS
Transient voltage suppressor
Current limitation
56V (1500W/1ms)
3.5 – 32VDC
-40->+100°C
-25->+90°C
10 minutes
12-24VDC
30mOhms
5-60VDC
35mADC
VALUE
VALUE
48VDC
0.9K/W
32VDC
10K/W
1VDC
175°C
100°C
0.7nF
2.5kV
2.5kV
2.5kV
100V
320A
<8pF
1.3V
5mA
3mA
1GΩ
Absolute limits
S/CON/SOM040100/A/08/12/05
Please contact us
t : Overvoltage duration
T: Time between 2 overvoltage
Motor
⇒
t
max
(
Uto
P
=
(
protection
−
(
Uto <
Uto
Ut
max)
T
−
)
Utp
=
Ut
Page 2/5 UK
0
1
.
W
-Icmax<100µA
@Utmax @Tjmax
@∆Tra=75°C
@∆Tra=75°C
75
@Iemax @Tjmax
max)
×
typical OFF= 2.6V
typical ON=3.3V
-100µA/°C
See fig. 5
See fig. 5
See fig. 7
See fig. 8
See fig. 7
(limits)
Ie
@Ie=80A
max
INFO.
INFO.
@Uc=0
×
×
t
Ie
≤
1