84138000 Crouzet USA, 84138000 Datasheet - Page 2

SSR, DIN RAIL MOUNT, 260VAC, 32VDC, 20A

84138000

Manufacturer Part Number
84138000
Description
SSR, DIN RAIL MOUNT, 260VAC, 32VDC, 20A
Manufacturer
Crouzet USA
Datasheet

Specifications of 84138000

Control Voltage Type
DC
Control Voltage Range
0VDC To 32VDC
Operating Voltage Range
90VAC To 260VAC
Contact Configuration
1NO
Load Current
20A
Relay Terminals
Screw
Brand/series
RHP Series
Contact Form
SPST-NO
Current, Output
20 A
Current, Rating
20 A
Function
Zero-Switching
Mounting Type
DIN Rail
Number Of Pins
4
Relay Type
Hybrid
Standards
UL⁄cUL, CE
Termination
Terminal Block
Voltage, Control
32 VDC
Voltage, Rating
260 VAC
Rohs Compliant
Yes
Load Voltage Rating
4 VDC to 32 VDC
Load Current Rating
100 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Hybrid Power Relay – RHP (Single Pole Relay)
Operation:
Contactor
Output of the contactor is closed when the input is On.
Output of the contactor is opened when the input is Off.
Led is On when the output is closed.
Bistable Relay
Output of the bistable changes of status for every pulse on the input
and stays in its position between pulses.
Front plate push button allows to select the operation mode:
Stop – led off – output off
On forced – led flashing – output on
Auto – led on – bistable relay operation
Day/night contactor
Output of the contactor is closed when the input is On
Output of the contactor is opened when the input is Off.
Front plate push button allows to select the operation mode:
Stop – led off – output off
On forced – led flashing – output on – back to the Auto mode at the
next change of the input.
Auto – led on – day/night contactor operation
Compliance
CEI/EN 60947-4-3 (industrial environment)
CEI/EN 60669-2-1 (household environment)
CEI/EN 60601-1 (medical environment)
CEI/EN 60947-7-1 (connections in industrial env.)
CEI/EN 60998-2-1 (connections in household env.
Insulation:
dielectric CEI/EN 60669-2-1:
Insulation CEI/EN 60669-2-1:
Vibrations CEI/EN 60068-2-6:
20 Amp output (Resistive only)
Every SSR advantage without the drawbacks
Lifetime > 5 million operations full load
Noiseless
Functions: contactor – bistable
17.5 mm DIN rail mount
UL/c UL (listed)
Label NF-USE
CE compliant
Installation category: 3
pollution: 3
CEI60664-1: 4KV/3
2 KV/1mm / 1mA / 50 Hz
> 5MΩ/500VDC / 1 min
60
44
frequencies: 10 to 55 Hz
magnitude: 0,35 mm
5.5
17.5
1
2
N
1
2
LOAD
3
4
3
I
4 A2
90...
260V~
A1
A2
A1
Type
Part number
AC input contactor
DC input contactor
AC input distable relay
AC input day/night contactor
Specifications
Power supply
Frequency
Max. power consumption
Input Control
Voltage
Frequency
Value
Min. time input
Output
Voltage
Max. current
Overload current 20A
Min current
Frequency
Contact
Switching frequency
lifetime
leakage current
Acoustic noise
terminal capacity
2 x 2.5 mm2 without ferrule
1 x 4 mm2 without ferrule
Torque
Operating temperature:
Storage temperature
Humidity
Housing
protection
(CEI 60529)
weight
Input OFF
Input ON
ON position
switching
90-260 Vac
50 / 60 Hz
11 VA
90-260 Vac
50 / 60 Hz
0 – 46 Vac
76 – 260 Vac
50 ms
90-260 Vac
20A in AC1 / AC51 / AC7a
AC-51: 1,25 x Ie – 60s: 50 – 30
(CEI 60947-4-3)
100mA in AC1 / AC51 / AC7a
50 / 60 Hz
N.O.
6 / min
> 5,000,000
< 5 mA
< 35 dB @ 1m
< 50 dB @ 0.5m
2 x 1.5 mm2 with ferrule
1Nm maxi. screw M3 (CEI 60947-1)
–5°C to +55°C
–40°C to +85°C
90 to 95% non-condensing
self extinguish
housing IP 50
terminal IP 20
70 gr
0-32 Vdc
0 – 1 Vdc
4 – 32 Vdc
50 ms
84 138 001
84 138 000
84 138 101
84 138 201
1-3
1

Related parts for 84138000