W222ACPFX-27 Magnecraft / Schneider Electric, W222ACPFX-27 Datasheet - Page 7

TIME DELAY RELAY, DPDT, 30MIN, 120VAC

W222ACPFX-27

Manufacturer Part Number
W222ACPFX-27
Description
TIME DELAY RELAY, DPDT, 30MIN, 120VAC
Manufacturer
Magnecraft / Schneider Electric
Datasheet

Specifications of W222ACPFX-27

Contact Configuration
DPDT
Nom Input Voltage
120VAC
Delay Time Range
2min To 30min
Timing Adjustment
Knob
Relay Mounting
Plug In
Peak Reflow Compatible (260 C)
Yes
Supply Voltage
120VAC
Display Type
Time-Delay Relay
Timing Range
2 min to 30 min
Contact Form
DPDT
Contact Rating
10 A
Termination Style
Plug-In
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DESCRIPTIONS OF
TIME DELAY FUNCTIONS
INPUT
POWER
OUTPUT
CONTACTS
ONE SHOT (RETRIGGERABLE)
Continuous power must be applied to the input during
all timing sequences. Upon closure of external control
switch, output contacts transfer and timing period
begins. When timing period ends, output contacts
return home. Once the timing period begins, the control
switch may remain closed or opened without affecting
timing. To repeat this cycle, the control switch must
be open, or opened at the end of the timing period, and
then closed to start timing period over again.
Some typical Applications: Vending machines,
dispensing controls, machine control, welding control,
INTERVAL
contacts transfer and the delay period begins. At the
end of the time delay period, the output contacts return
home. Input power must be interrupted to recycle timer.
Some typical Applications: Machine control, End of
process alarm, Welding control, Photographic timing.
INPUT
POWER
CONTROL
SWITCH
OUTPUT
CONTACTS
Upon application of power to the input, the output
DELAY
DELAY
U. S.
TELEPHONE: (843)393-5778
FAX:
WEBSITE:
EMAIL:
U. S.
DELAY
A.
A.
info@magnecraft.com
www.magnecraft.com
(843)393-4123
ON
OFF
TRANSFERRED
HOME
ON
OFF
CLOSED
OPEN
TRANSFERRED
HOME
APPLICA
APPLICA
INPUT
POWER
CONTROL
SWITCH
OUTPUT
CONTACTS
CONTROL
SWITCH
OUTPUT
CONTACTS
ON-DELAY & OFF-DELAY- (COMBINATION)
Continuous power must be applied to the input during all
timing sequences. Upon closure of the external control
switch, first time delay period
period ends, output contacts transfer. Then, when control
switch is opened, second delay period T
T
timing cycle, repeat this sequence from the beginning.
If the prevailing open or closed status of the control switch
is changed during either T
stops. Position of output contacts remain as they were.
Returning control switch to its pre-changed position
restarts interrupted timing period from the beginning and
normal timing resumes.
Some typical Applications: Cascade starting & stopping
of heavy loads, laboratory equipment, machine control
TRUE OFF DELAY- (SLOW RELEASE)
Upon application of power to the input, output contacts
transfer. The delay period begins when power is removed
from the input. If power is supplied to input during the
timing period, time is reset and time delay period starts
over again when power is removed from the input.
Some typical Applications: Loss of power alarm control,
Burglar alarms.
INPUT
POWER
OUTPUT
CONTACTS
2
ends, output contacts return home. To repeat this
EUROPE
TELEPHONE: 4989 / 75080310
FAX:
WEBSITE:
EMAIL:
EUROPE
T
T
1
TION DA
1
TION DA
Interrupted
4989/ 7559344
renatesteinback@magnecraft.de
www.magnecraft.com
T
DELAY
1
1
T
or T
2
T
T
1
2
2
Interrupted
begins. When T
Timing periods, timing
T
2
T
T
2
ON
OFF
TRANSFERRED
HOME
ON
OFF
CLOSED
OPEN
TRANSFERRED
HOME
CLOSED
OPEN
TRANSFERRED
HOME
begins. When
A
A
1
4...
6