Manufacturer Part Number
TDMA
Description
TIMER, MULTIFUNCTION
Manufacturer
IMO PRECISION CONTROLS
Datasheet

Specifications of TDMA

Contact Configuration
SPCO
Nom Input Voltage
230V
Delay Time Range
0.05s To 10days
Adjustment Type
Knob
Relay Mounting
DIN Rail
Svhc
No SVHC (15-Dec-2010)
Coil Voltage Vac Nom
230V
Coil Voltage Vdc
RoHS Compliant
TD/03/03
DIN Timers TD
22.5mm DIN rail mounting Electronic Timers
Options and ordering codes
DIN rail mount
timers
Multi-function
4 function
Multi-function 2 C/O
On-delay
Off-delay
Asymmetrical recycling
True off-delay 3 minutes
True off-delay 10 minutes
Star/Delta
On delay single function
Specification
Operation modes
Time range
Accuracy
Supply voltage
Nominal power
consumption
Input signal
Control contact must be
90% of A1-A2
Contact configuration
Control output
Life expectancy
Allowable ambient
temperature
IP rating
Terminals
AC/DC coil operation
Multi-time range
Multi-function, On-delay, Off-delay and Star/Delta
versions
Voltage range selectable
Marking plate cover
TD
Mechanical
Electrical
Terminals
TD
Enclosures
MA
0.05sec- -
8A@250VAC
MA
MC
MB
Power on
EA
RA
AA
AB
SD
SF
24V 1.5VA/
400,000
IA
10 days
2VA 230V
30 x 10
A,B,C,D
1W-110V
contact
E,F,G,H
control
TDMA
1 C/O
8VA
6
All timers are Multi-voltage
I/P 24VAC/DC and
100-230VAC selectable
on unit. Except EA+RA
models
EA + RA models only
EA + RA models only
SF model only
SF model only
SF model only
8A@250VAC
Power on
24V 1.5VA/
0.05sec-
400,000
30 x 10
10 days
2VA 230V
1W-110V
A,B,F,G
contact
control
TDMC
1 C/O
8VA
6
0.05sec- -
programmable
8A@250VAC
Power on
24V 1.5VA/
400,000
30 x 10
A,B,C,D
10 days
2VA 230V
1W-110V
contact
E,F,G,H
control
TDMB
2 C/O
11VA
24VDC ±10%, 24VAC-15% +10%, 110-230VAC-15% +10%
Multi Voltage Options
6
0.05sec- -
5A@250VAC
Power on
24V 1.5VA/
100,000
10 x 10
10 days
2VA 230V
Multi Voltage Options
1W-110V
110VAC + 24VAC/DC
230VAC + 24VAC/DC
TDEA
1 C/O
8VA
A
Box clamp screw terminal upto 4mm
24VAC/DC
6
110VAC
230VAC
0.05sec- - 0.05sec- -
5A@250VAC
Power on
24V 1.5VA/
100,000
10 days
2VA 230V
10 x 10
1W-110V
contact
control
TDRA
1 C/O
-25 ˚C upto +55˚C
11VA
B
±0.5% FS
6
IP40
IP20
5A@250VAC
Power on
24V 1.5VA/
400,000
30 x 10
10 days
2VA 230V
1W-110V
Rp,Ri
1 C/O
TDIA
8VA
6
5A@250VAC 5A@250VAC
Power on
0.1sec- -
24V 1.5VA/
100,000
30 x 10
4VA 230V
1W-110V
1 C/O
TDAA
3 min
15VA
2
T
6
0.1sec- -
24V 1.5VA/
Power on
100,000
30 x 10
4VA 230V
1W-110V
10 min
TDAB
1 C/O
15VA
T
6
www.imopc.com
40-100ms Y
0.5sec-3minY
8A@250VAC
rest position
24V 1.5VA/
Power on
1 C/O with
400,000
2VA 230V
30 x 10
1W-110V
TDSD
11VA
S
6
5A@250VAC
Power on
0.1sec- -
24V 1.5VA/
100,000
10 x 10
2VA 230V
1W-110V
10 min
TDSF
1 C/O
11VA
A
6

Related parts for TDMA

TDMA Summary of contents

Page 1

... Multi-function 2 C/O MB On-delay EA Off-delay RA Asymmetrical recycling IA True off-delay 3 minutes AA True off-delay 10 minutes AB Star/Delta SD On delay single function SF Specification TDMA Operation modes A,B,C,D E,F,G,H Time range 0.05sec days Accuracy Supply voltage Nominal power 24V 1.5VA/ consumption 1W-110V 2VA 230V 8VA Input signal Power on ...

Page 2

DIN Timers TD Mode functions memory R U U/t Rp ...

Page 3

... A21 Control Function Function Rp: without link Dimensions TDMA, TDEA, TDRA, TDIA, TDAA, TDAA, TDAB, TDSD, TDSF 65mm 70mm 5mm TD/03/03 continued TDMB Positions of function switch with one contact as Both contacts delayed instantaneous c. Start function and H by control contact A1-B1 if instantaneous option is selected R1 becomes timed and R2 becomes instantaneous ...

Related keywords