RE8TA11BU TELEMECANIQUE, RE8TA11BU Datasheet
RE8TA11BU
Specifications of RE8TA11BU
Related parts for RE8TA11BU
RE8TA11BU Summary of contents
Page 1
Applications 2 Enclosure type Timing range Number of ranges Extreme values Output circuit Control circuit voltage, depending on model Type Pages Te 2/2 Electronic timers RE7 : 4233062 - 4233189 Selection guide RE8 : 4233190 - 4233244 Electronic timers enable ...
Page 2
Relay outputs provide complete isolation between the supply circuit and the output possible to have several output circuits. Universal: multi-voltage, multifunction timing ranges 7 0.05…1 s 0.15…3 s 0.5…10 s 1.5…30 s 5…100 s 15…300 ...
Page 3
... The On and Off delays are adjusted by 2 different potentiometers. Energisation of the relay causes the output contact to close instantaneously and start the timing period. The contact returns to its initial position when the set time delay (t) has elapsed or if the supply is cut off before the end of the timing period. ...
Page 4
... External control of starting: opening of an external contact connected to the relay starts the timing period. Closing of this contact resets the timer. External control of partial stop of time delay: closing of an external contact connected to the relay allows the timing period to be interrupted. The time elapsed is memorised ...
Page 5
... Zelio Time - timing relays Relay output, width 22.5 mm, universal General characteristics The RE7 range of relays, with only 23 references, covers all timing applications. These relays offer multi-range timing from 300 h. They are multi-voltage. Three models combine several different functions: multifunction relays. ...
Page 6
... V/10 mA Nickel Silver 90/10 (except RE7-RBiiMU: gold flashed silver alloy < 3/4-wire PNP and NPN Telemecanique sensors or other sensors without an internal load Linear 0 shielded cable: shielding linked to terminal Z2 Curve 2 Reduction factor k for inductive loads (applies to values taken from the durability curve opposite) ...
Page 7
... RE7 2/20 Zelio Time - timing relays Relay output, width 22.5 mm, universal On-delay relays Functions, references On-delay relays Time delay adjustable from 0. 300 ranges (see setting-up procedure on page opposite). On-delay relay External control for Start on start of time delay energisation RE7-TM RE7-TL, TM, TP ...
Page 8
... Switch for converting the second C/O contact to instantaneous mode (for RE7-TP13BU). 4 LEDs, depending on the model: - Green LED U/T: flashes during the time delay period, permanently on outside the time delay period Yellow LED R1: on when the 1 relay is energised. - Yellow LED R2: on when the 2 nd relay is energised ...
Page 9
... Relay output, width 22.5 mm, universal On-delay and Off-delay relays Functions, references On-delay and Off-delay relays Time delay adjustable from 0. 300 ranges (see setting-up procedure on page opposite). External control for Remote control for partial stop of time delay start of time delay RE7-MA11BU and MV11BU ...
Page 10
... Off-delay adjustment (tr). 3 Switch for converting the second changeover contct to instantaneous mode (RE7-MA13BU). 4 LEDs, depending on the model : - Green LED: flashes during the time delay period, permanently on outside the time delay period - Yellow LED 1: on when the 1 st relay is energised nd - Yellow LED 2: on when the 2 ...
Page 11
... V (1) If the device has been stored, de-energised, for more than a month, it must be energised for about 15 seconds to activate it. Subsequently, a time of > enough to activate the time delay. If this time is not complied with, the relay will remain energised indefinitely. (2) By external potentiometer ordered separately. If external potentiometer is fitted, the internal potentiometer is automatically disconnected ...
Page 12
... Yellow LED R2: on when 2 relay is energised. - RE7-RBiiMW: the green LED does not flash during the time delay period and there is only one yellow LED (R). Adjustment of the time delay - Select the timing range immediately greater than the time required, using selector switch 2. ...
Page 13
... Zelio Time - timing relays Relay output, width 22.5 mm, universal Pulse on energisation relays Functions, references Pulse on energisation relays Time delay adjustable from 0. 300 ranges (see setting-up procedure on page opposite) Pulse on energisation relay Start on opening of Start on energisation external control contact RE7-PE, PP RE7-PM, PD ...
Page 14
... Switch for converting the second changeover contact to instantaneous mode (RE7-PP13BU and PD13BU). 4 LEDs, depending on the model: - Green LED: flashes during the time delay period (except for the first 2 timing ranges), permanently on outside the time delay period st - Yellow LED 1: on when 1 relay is energised ...
Page 15
... Zelio Time - timing relays Relay output, width 22.5 mm, universal Flashing relays Functions, references Flashing relays Time delay adjustable from 0. 300 ranges (see setting-up procedure on page opposite). Symmetrical flashing relay Asymmetrical flashing relay RE7-CL, CP Start during the ON period RE7-CV (X2Z2 linked) ...
Page 16
... Adjustable Off-delay (tr). 3 Switch for converting the second changeover contact to instantaneous mode (RE7-CP13BU). 4 LEDs, depending on the model : - Green LED: flashes during the time delay period, permanently on outside the time delay period st - Yellow LED 1: on when 1 relay is energised - Yellow LED 2: on when 2 ...
Page 17
... With contact for switching to star connection 42… 110…240 V 1 (1) Adjustable time delay for operation in star connection and and fixed (50 ms) for switching from star to delta connection to ensure sufficient breaking time. Available 2nd Quarter 2001 (1) With contact for switching to star connection ...
Page 18
... LEDs, depending on model : - Green LED: flashes during the time delay period (except the first 2 timing ranges), permanently on outside the time delay period - Yellow LED 1: on when 1 st relay is energised nd - Yellow LED 2: on when 2 ...
Page 19
... RE7-MY Te 2/32 Zelio Time - timing relays Relay output, width 22.5 mm, universal Multifunction relays Functions, references Adjustable time delay from 0. 300 ranges (see setting-up procedure on page opposite). On-delay relay Pulse on energisation relay RE7-ML, MY with start on energisation RE7-ML, MY Supply Supply C/O C/O ...
Page 20
... Switch for converting the second changeover contact to instantaneous mode (depending on model). 5 LEDs, depending on the model: - Green LED: flashes during the time delay period (except for the first 2 timing ranges), permanently on outside the time delay period Yellow LED 1: on when 1 relay is energised. ...
Page 21
... Characteristics : pages 2/18 and 2/19 References : pages 2/20 to 2/32 Setting-up : page 2/35 RE7 Dimensions 2 80 Screw fixing Te 2/34 Zelio Time - timing relays Relay output, width 22.5 mm, universal Dimensions, mounting Rail mounting 22,5 Ø4 89,5 82 ...
Page 22
... Connection of an external control contact without using terminal Z2: - possible on all RE7 relays with external control option except RE7-RA11BU - d.c. supply only + A1 – Connection of a Telemecanique 3-wire NPN or PNP sensor without using terminal Z2: - only possible on relay RE7-iiiiBU - d.c. supply only + BN B1B2 NPN ...