MK 7850N.82/200 AC/DC12-240V DOLD & SOEHNE, MK 7850N.82/200 AC/DC12-240V Datasheet - Page 5

RELAY, MULTIFUNCTION

MK 7850N.82/200 AC/DC12-240V

Manufacturer Part Number
MK 7850N.82/200 AC/DC12-240V
Description
RELAY, MULTIFUNCTION
Manufacturer
DOLD & SOEHNE

Specifications of MK 7850N.82/200 AC/DC12-240V

Contact Configuration
2PCO
Nom Input Voltage
240V
Delay Time Range
0.02s To 300h
Adjustment Type
Screwdriver Slot
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
240V
Coil Voltage Vdc Nom
12V
Contact Current
RoHS Compliant
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
Yes
MK 7850N.82/61:
MK 7850N.82/500:
MK7850.82/300:
Ordering example for variant
MK 7850N .82 PS /_ _ _ AC/DC 12 ... 240 V
MK 7850N.82/200 AC/DC 12 ... 240 V
Article number:
• Output:
• Nominal voltage U
• Time ranges:
• Width:
AD 3:
Degree of protection
front side:
Standardtype
Variants
Accessories
N
:
With UL-approval (Canada/USA)
With 2 additional functions selectable via slide
switch S1:
- Cyclic timer, start with break (TP)
- Fleeting on make and break (EW/AW)
second time setting t2, connection facility
for 2 remote potentiometers 10 kΩ to adjust
t1 and t2
connection facility for 1 remote potentiometer
10 kΩ
0054050
2 changeover contacts, one
programmable as instantaneous
contact
AC/DC 12 ... 240 V
from 0.02 s ... 300 h
22.5 mm
External potentiometer 10 kΩ
IP 60
The external potentiometer is used for
remote setting of the time delay. The
internal potentiometer of the timer must
be set to min. time delay.
Nominal voltage
Variant
Type of terminals
without indication:
terminal blocks fixed,
with screw terminals
PC (plugin cage clamp):
plugable terminal
blocks with cage
clamp terminals
PS (plugin screw):
plugable terminal
blocks with screw
terminals
Contacts
Type
Connection with 2 different control voltages.
5
Control with parallel connected load
Connection examples
L(+)
N(-)
L(+)
N(-)
L(+)
N(-)
AC/DC12...240V
S1
S1
A1
A2
MK7850N
A1
A2
MK7850N
S1
B1(+)
B1(+)
S2
AC/DC12...240V
conductor
S2
e.g. PLC
output
semi-
B1(+)
M8127
M8292
DC24V
A1
A2
MK7850N
M5794
X2
X3
voltfree
control contact
(stop function)

Related parts for MK 7850N.82/200 AC/DC12-240V