M1SMT 24/230V BROYCE CONTROL, M1SMT 24/230V Datasheet

TIMER, MULTIFUNCTION, 6 FUNCTION

M1SMT 24/230V

Manufacturer Part Number
M1SMT 24/230V
Description
TIMER, MULTIFUNCTION, 6 FUNCTION
Manufacturer
BROYCE CONTROL
Datasheet

Specifications of M1SMT 24/230V

Contact Configuration
SPCO
Nom Input Voltage
230VAC
Delay Time Range
0.5s To 60min
Adjustment Type
Knob
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
250V
Coil Voltage Vdc Nom
25V
M1SMT
q
q
q
q
q
q
q
Troubleshooting
Supply voltage Un:
(AC: 48 - 63Hz)
* Dual voltage
Supply variation:
Power consumption:
(@ 1.15 x Un)
Functions:
(user selectable)
Time delay (t)
(user selectable)
Repeat accuracy:
Minimum trigger time:
Reset time:
Ambient temperature:
Relative humidity:
Output:
Output rating:
Electrical life:
Housing:
Weight:
Mounting option:
Terminal conductor
Approvals:
S
S
size:
Time Delay
BEFORE INSTALLATION, ISOLATE THE SUPPLY.
Connect the unit as shown in the diagram above.
Apply power (green LED on).
Unit will operate according to function selected (see 'function
diagram').
Check wiring and voltage present.
Check polarity (for DC supplies only).
0.5 - 60 sec.
0.5 - 60 min.
use of such information shall be entirely at the user's own risk
M
M
accurate (subject to change without prior notice); however,
The information provided in this literature is believed to be
I
TECHNICAL SPECIFICATION
H+44 (0) 1902 773746 G+44 (0) 1902 420639 Email: sales@broycecontrol.com Web: http://www.broycecontrol.com
NSTALLATION AND SETTING
6 FUNCTIONS
MULTI TIME RANGE
DUAL VOLTAGE
OUTPUT RELAY 8A
SUPPLY INDICATION
RELAY INDICATION
DIN RAIL HOUSING (17.5mm)
A
A
Installation work must be carried
B
B
out by qualified personnel.
A
D
(V.F.C. closed)
(V.F.C. open)
Delay off
Function
A
A
FUNCTION DIAGRAM
DIAGRAMMEDE FONCTION
FUNKTIONSDIAGRAM
B
B
12V AC, 12V DC
24V AC/DC / 110V AC *
24V AC/DC / 230V AC *
0.85 - 1.15 x Un
AC: 0.77VA (13.8V), 0.4VA
(27.6V), 2.3VA (126V), 4.8VA (264V)
DC: 0.37W (13.8V), 0.58W (27.6V)
See "function diagram"
0.5 - 60S, 0.5 - 60M
> 10mS (110 / 230V)
> 220mS (12 / 24V)
-20 to +60 C
+95%
1 x C.O.
AC1 250V AC 8A (2000VA)
AC15 250V AC 5A (no),
3A (nc)
DC1 25V DC 8A (200W)
to UL94 VO
to BS5584:1978
(EN50 002, DIN 46277-3)
Conforms to UL, CUL, CSA & IEC.
CE and
100mS
70g
0.5% (constant conditions)
150,000 (AC1)
2 x 2.5mm
Function / Fonction / Funktion - A
Function / Fonction / Funktion - D
Broyce Control Ltd., Pool Street, Wolverhampton, West Midlands WV2 4HN. England
B
E
Multi Function, Multi Time Range Timer
Multi-fonctions, minuteur multi-domaines de temps
Multi Funktion, Vielbereich Zeitregler
(see 'function diagram')
(V.F.C. closed)
(V.F.C. open)
t
t
Delay on
A
A
Compliant
2
solid / stranded
B
B
t
t
Interval
C
F
(Supply initiated)
(Supply initiated)
Function / Fonction / Funktion - B
A
A
Function / Fonction / Funktion - E
B
B
t
t
t
t
q
q
q
q
q
q
q
Délai de temps
S
S
Intervention (pour régler un problème)
Tension d ' alimentation Un:
(AC: 48 - 63Hz)
* Double voltage
Variation d ' alimentation:
Puissance consommée:
(@ 1.15 x Un)
Fonctions:
(possibilité de choix pour
l ' utilisateur)
Délai de temps (t):
(possibilité de choix pour
l ' utilisateur)
Précision répétée:
Temps de déclenchement
Temps de remise à zéro:
Température ambiante:
Humidité relative:
Sortie:
Mesure de sortie:
Durée de vie électrique:
Boitier:
Poids:
Option de montage:
Taille du conducteur
Homologations:
minimum:
terminal:
réserve de changement sans avis préalable) toutefois aux risques et
AVANT MONTAGE, ISOLER L ' ALIMENTATION
Branchement comme indiqué dans le diagramme ci-dessus.
Appliquer le puissance (LED verte allumée).
L ' unité opérera selon la fonction sélectionne (voir 'Diagrammede
fonction').
Vérifier les fils et le voltage présent.
Vérifier la polarisation (seulement pour les alimentations en
courant continu).
Les indications contenues dans ce document sont exactes (sous
0.5 - 60 sec.
0.5 - 60 min.
M
M
MONTAGE ET MISE AU POINT
FICHES TECHNIQUES
Function / Fonction / Funktion - C
Function / Fonction / Funktion - F
A
A
6 FONCTIONS
DOMAINE MULTI-TEMPS
DOUBLE VOLTAGE
RELAIS DE SORTIE 8A
INDICATION D ' ALIMENTATION
INDICATION DE RELAIS
LOGEMENT DU RAIL DIN (17.5mm
B
B
t
t
menés à bien par le personnel qualifié.
Des travaux d'installation doivent être
A
D
Délai d ' arrêt
(V.F.C. fermés)
Fonction
(V.F.C. ouvert)
périls de l ' utilisateur
A
A
B
B
12V AC, 12V DC
24V AC/DC / 110V AC *
24V AC/DC / 230V AC *
0.85 - 1.15 x Un
AC: 0.77VA (13.8V), 0.4VA
(27.6V), 2.3VA (126V), 4.8VA (264V)
DC: 0.37W (13.8V), 0.58W (27.6V)
Voir "diagrammede fonction"
0.5 - 60S, 0.5 - 60M
> 10mS (110 / 230V)
> 220mS (12 / 24V)
-20 à +60 C
+95%
1 x Inverseur
AC1 250V AC 8A (2000VA)
AC15 250V AC 5A (travail),
3A (repos)
DC1 25V DC 8A (200W)
à UL94 VO
à BS5584:1978
(EN50 002, DIN 46277-3)
Se conformer à UL, CUL, CSA &
IEC. CE et
0.5% (condition constante)
100mS
150,000 (AC1)
70g
2 x 2.5mm
(voir 'Diagrammede fonction')
Délai opérationnel
B
E
CONNECTION DIAGRAM
DIAGRAMME DE CONNECTION
SCHALTBILDANSCHLUSS
(V.F.C. fermés)
(V.F.C. ouvert)
Link terminals 'A1' and 'A3'
for 24V AC/DC operation
only.
Relier ensemble les bornes
'A1' et 'A3' seulement pour
des voltages 24V AC/DC.
Die Verbindung der
Anschlussklemmen 'A1'
und 'A3' nur zur
Bedienung für 24V AC/DC
benutzen.
A
A
2
B
B
toron / multi-filaire
Intervalle
Déférence
(initié par l'alimentation)
(initié par l'alimentation)
C
F
A
A
)
B
B
-ve
Supply
*link
q
q
q
q
q
q
q
Zeitsteuerung
S
S
Störungsbehebung
Versorgungsspannung Un:
(AC: 48 - 63Hz)
* Dopplespannung
Wechselversorgung:
Energieverbrauch:
(@ 1.15 x Un)
Funktionen:
(Selbstwähler)
Zeitsteuerung (t):
(Selbstwähler)
Genauigkeit wiederholen:
Minimum Zeitauslöser:
Stellzeit:
Umgebungstemperatur:
Allgemeiner
Ausgang:
Ausgangsleistung:
Elektrische Lebensdauer:
Gehäuse:
Gewicht:
Befestigungswahl:
Anschlussklemme
Genehmigungen:
Feuchtigkeitsgehalt:
/ Kabelgrösse:
VOR EINBAU DIE STROMVERSORGUNG ISOLIEREN
Stromversorgung anschliessen wie im Schaltbild unten
angezeigt.
Energie anbringen (LED grün an).
Einheit schaltet sich je nach der gewählten Funktion ein (siehe
'Funktionsdiagram').
Überprüfung von Leitungen und gegenwärtiger Spannung.
Überprüfung von Polung (nur für Gleichstromversorgung).
Angaben, (Änderungen vorbehalten) jedoch diese Änderungen
M
0.5 - 60 sec.
M
0.5 - 60 min.
Es handelt sich in diesen Unterlagen um uns genau bekannte
+ve
EINBAU UND EINSTELLUNG
TECHNISCHE DATEN
A3
A1
16 18
A
A
6 FUNKTIONEN
MULTIZEITBEREICH
DOPPELSPANNUNG
AUSGANGSRELAIS 8A
VERSORGUNGS - INDIKATION
RELAIS INDIKATION
DIN SCHIENENGEHÄUSE (17.5mm)
A2
Installation Arbeit muß von qualifiziertem
B
B
B1
15
External
Contact
N.O.
laufen auf eigene Gefahr des Benutzers.
Personal durchgeführt werden.
Verzögerung aus
(V.F.C. geschlossen)
A
D
(V.F.C. Offen)
Funktion
A
A
Width / largeur / Breite. 17.5 mm (DIN 43880)
MOUNTING DETAILS
INSTRUCTIONS DE MONTAGE
MONTAGEAUFÜHRUNGEN
surface mounting
B
B
Withdraw clips
fully when
12V AC, 12V DC
24V AC/DC / 110V AC *
24V AC/DC / 230V AC *
0.85 - 1.15 x Un
AC: 0.77VA (13.8V), 0.4VA
(27.6V), 2.3VA (126V), 4.8VA (264V)
DC: 0.37W (13.8V), 0.58W (27.6V)
siehe "funktionsdiagram"
0.5 - 60S, 0.5 - 60M
> 10mS (110 / 230V)
> 220mS (12 / 24V)
-20 bis +60 C
+95%
1 x Wechsler
AC1 250V AC 8A (2000VA)
AC15 250V AC 5A (Schließer),
3A (Öffner)
DC1 25V DC 8A (200W)
bis UL94 VO
bis BS5584:1978
(EN50 002, DIN 46277-3)
Anmerkung: UL, CUL, CSA & IEC
CE und
Insert screwdriver
to release clips
0.5% (Bedingungen gleichbleibend)
100mS
70g
2 x 2.5mm
150,000 (AC1)
Schaltverzögerung
(V.F.C. geschlossen)
(siehe 'Funktionsdiagram').
B
E
(V.F.C. Offen)
A
A
B
B
Übereinstimmung
2
89 (excl. clips)
Festdraht / Litze
93 (+/- 1mm)
Intervall
(Versorgungseinleitung)
45
C
F
(Versorgungseinleitung)
A
A
B
B
M1SMT-1-B
49 59

Related parts for M1SMT 24/230V