H3DE-F Omron, H3DE-F Datasheet - Page 3

Solid State Timer

H3DE-F

Manufacturer Part Number
H3DE-F
Description
Solid State Timer
Manufacturer
Omron
Datasheet

Specifications of H3DE-F

Contact Configuration
SPCO
Nom Input Voltage
230V
Timing Adjustment
Screwdriver Slot
Relay Mounting
DIN Rail
Length/height, External
79mm
Voltage Ac
250V
External Width
22.5mm
Voltage Rating Vdc
30V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H3DE-F-AC/DC24-230
Manufacturer:
TELEDYN
Quantity:
102
H3DE-F
Note: For reference:
16
Accuracy of operating
time
Setting error
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand
voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Life expectancy
EMC
Enclosure rating
Weight
Characteristics
A maximum current of 0.15 A can be switched at 125 VDC (cos =1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
100 M min. at 500 VDC
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60
Hz) for 1 min.
Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.
Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.
3 kV (between power supply terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) 1.5 kV
Malfunction: 4 kV
Destruction: 8 kV
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Malfunction: 100 m/s
Destruction: 1,000 m/s
Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Electrical:
(EMI)
Emission Enclosure: EN55011 Group 1 class B
Emission AC Mains: EN55011 Group 1 class B
(EMS)
Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3)
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3)
Immunity Surge: EN61000-4-5: 2 kV common mode (level 3)
IP30 (IP20 for terminal block)
Approx. 110 g
1% max. of FS ( 1% 10 ms max. at 1.2-s range)
10%
0.5% max. of FS ( 0.5% 10 ms max. at 1.2-s range)
2% max. of FS ( 2%
0.05 s max. of FS
100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)
2
(approximately 10G)
2
10 ms max. at 1.2-s range)
(approximately 100G)
8 kV air discharge (level 3)
1 kV control port with capacitive clamp (level 3)
1 kV differential mode (level 3)
H3DE-F