H3CR-H8L AC100-120 M Omron, H3CR-H8L AC100-120 M Datasheet - Page 16

SOLID STATE TIMER, DPDT, 12MIN, 120VAC

H3CR-H8L AC100-120 M

Manufacturer Part Number
H3CR-H8L AC100-120 M
Description
SOLID STATE TIMER, DPDT, 12MIN, 120VAC
Manufacturer
Omron
Series
H3CR-Hr
Datasheet

Specifications of H3CR-H8L AC100-120 M

Contact Configuration
DPDT
Nom Input Voltage
120VAC
Delay Time Range
0.05min To 12min
Timing Adjustment
Knob
Relay Mounting
DIN Rail
Relay Type
Integrated
Function
Off-Delay
Circuit
DPDT (2 Form C)
Delay Time
0.05 Min ~ 12 Min
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 120VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3CR-H8L-AC100-120M
H3CRH8LAC100120M
Z2386
■ Life-test Curve
Connections
■ Block Diagrams
■ I/O Functions
Without Reset Input (H3CR-H8L)
With Reset Input (H3CR-H8RL/-HRL)
Inputs
Outputs
10,000
1,000
5,000
100
500
250 VAC (cosφ = 0.4)
AC (DC) input
AC (DC) input
Reset
Control output
Load current (A)
http://www.ia.omron.com/
30 VDC L/R = 7 ms
Reset input
250 VAC/30 VDC
(cosφ = 1)
Power failure
detection circuit
Power failure
detection circuit
Power supply
circuit
Power supply
circuit
Turns off the control output and resets the elapsed time.
Operates instantaneously when the power is turned on and time-limit resets when the set time is up
after the power is turned off.
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1)
Oscillation
circuit
Oscillation
circuit
and a maximum current of 0.1 A can be switched if L/R is 7 ms. In
both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC for H3CR-H8L/-HRL
and 100 mA at 5 VDC for H3CR-H8RL (failure level: P).
Input circuit
Time range/
unit selector
Time range/
unit selector
Counting
circuit
Counting
circuit
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Indicator
circuit
Indicator
circuit
Output
circuit
Output
circuit
Output
indicator
Output
indicator
H3CR-H
16