G2RL-1-CF-DC12 Omron, G2RL-1-CF-DC12 Datasheet - Page 3

POWER RELAY, SPDT, 12VDC, 12A, PC BOARD

G2RL-1-CF-DC12

Manufacturer Part Number
G2RL-1-CF-DC12
Description
POWER RELAY, SPDT, 12VDC, 12A, PC BOARD
Manufacturer
Omron
Datasheets

Specifications of G2RL-1-CF-DC12

Relay Type
General Purpose
Coil Voltage Vdc Nom
12V
Contact Current Max
12A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
24V
Coil Resistance
360ohm
Contact Configuration
SPDT
Brand/series
G2RL Series
Contact Form
SPDT
Current, Rating
12 A
Dielectric Rating
5000 VAC @ 1 (Min.) between Coil and Contacts
Dimensions
29 mm L x 12.7 mm W x 15.7 mm H
Function
General Purpose
Mounting Type
PCB
Number Of Pins
5
Power, Rating
3000⁄288 VA⁄W
Resistance, Coil
360 Ohms
Standards
UL, CSA, VDE
Temperature, Operating
-40 to +85 °C
Termination
Through Hole
Voltage, Control
12 VDC
Voltage, Rating
440 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
G2RL
CSA C22.2 (No. 14) (File No. LR31928)
VDE (EN61810-1) (Licence No. 119650)
Engineering Data
Note:
226
Maximum Switching Capacity
Ambient Temperature
vs Rated Carry Current
G2RL-1A
G2RL-1
G2RL-1A-E
G2RL-1-E
G2RL-2A
G2RL-2
G2RL
Contact your OMRON representative for the data on fully sealed models.
G2RL-2A, G2RL-2
G2RL-1A-E, G2RL-1-E
G2RL-1A, G2RL-1
G2RL-1A, G2RL-1
Model
Model
Ambient Temperature (°C)
Switching voltage (V)
DC resistive
load
AC resistive load
1 pole
1 pole (High capacity)
2 poles
SPST-NO
SPDT
SPST-NO (High capacity)
SPDT (High capacity)
DPST-NO
DPDT
Contact form
Contact form
Ambient Temperature
vs Maximum Coil Voltage
G2RL-1A-E, G2RL-1-E
5, 12, 18, 22, 24, 48 VDC
Ambient Temperature (°C)
Switching voltage (V)
3 to 48 VDC
DC resistive
load
Coil ratings
AC resistive load
Coil ratings
85
Note: The maximum coil voltage refers to
12 A at 250 VAC (cos φ =1)
12 A at 24 VDC (L/R=0 ms)
AC15:3 A at 240 VAC
DC13: 2.5 A at 24 VDC, 50 ms
16 A at 250 VAC (cos φ =1)
16 A at 24 VDC (L/R=0 ms)
AC15:3 A at 240 VAC (NO)
1.5 A at 240 VAC (NC)
DC13: 2.5 A at 24 VDC (NO), 50 ms
8 A at 250 VAC (cos φ =1)
8 A at 24 VDC (L/R=0 ms)
AC15:1.5 A at 240 VAC
DC13: 2 A at 30 VDC, 50 ms
12 A at 250 VAC (General use)
12 A at 24 VDC (Resistive)
16 A at 250 VAC (General use)
16 A at 24 VDC (Resistive)
8 A at 277 VAC (General use)
8 A at 30 VDC (Resistive)
the maximum value in a varying
range of operating power voltage,
not a continuous voltage.
G2RL-2A, G2RL-2
Contact ratings
Contact ratings
Switching voltage (V)
DC resistive
load
AC resistive load
G2RL

Related parts for G2RL-1-CF-DC12