TQ2-24VDC PANASONIC EW, TQ2-24VDC Datasheet - Page 5

RELAY, PCB, DPCO

TQ2-24VDC

Manufacturer Part Number
TQ2-24VDC
Description
RELAY, PCB, DPCO
Manufacturer
PANASONIC EW
Datasheet

Specifications of TQ2-24VDC

Relay Type
General Purpose
Coil Voltage Vdc Nom
24V
Contact Current Max
2A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Resistance
2.88kohm
Coil Type
DC Coil, Monostable
Coil Current
8.3mA
Nom
RoHS Compliant
Contact Configuration
DPCO
Rohs Compliant
Yes
4.-(1) Electrical life (DC load)
Tested sample: TQ2-12V, 6 pcs.
Condition: 1 A 30 V DC resistive load, 20 cpm
Change of pick-up and drop-out voltage
Change of contact resistance
6.-(1) Operate/release time characteristics
Tested sample: TQ2-12V, 10 pcs.
8. Distribution of set and reset voltage
Tested sample: TQ2-L2-12V, 35 pcs.
100
100
90
80
70
60
50
40
30
20
10
90
80
70
60
50
40
30
20
10
30
20
10
6
5
4
3
2
1
0
0
0
0
10 20 30 40 50
80
Ratio against the rated voltage, %V
Release time
5
Pick-up voltage
Coil applied voltage, %V
90
No. of operations, 10
No. of operations, 10
Operate time
100
10
5
Drop-out voltage
60
110
70 80 90 100
Set voltage
Reset voltage
15
120
4
4
Max.
Min.
Max.
Min.
10
20
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Max.
Min.
Max.
Min.
Max.
Min.
Change of contact resistance
5.-(1) Coil temperature rise (2C)
Tested sample: TQ2-12V
Measured portion: Inside the coil
Ambient temperature: 30 C
6.-(2) Operate/release time characteristics
Tested sample: TQ4-12V, 10 pcs.
9. Ambient temperature characteristics
Tested sample: TQ2-12V, 5 pcs.
100
90
80
70
60
50
40
30
20
10
70
60
50
40
30
20
10
0
6
5
4
3
2
1
0
0
–40
100 110 120 130 140 150
80
–20
5
Coil applied voltage, %V
No. of operations, 10
90
Coil applied voltage, %V
0
40
20
Release time
Operate time
10
100
Nominal coil voltage
20
–40
–20
86 F
3 to 12 V DC type
24 V DC type
40
Drop-out
voltage
Ambient temperature, C
110
60
15
Pick-up voltage
120
80
4
1 A
1 A
0 A
Max.
Min.
Max.
x
Min.
x
20
Max.
Min.
4.-(2) Electrical life (AC load)
Tested sample: TQ2-12V, 6 pcs.
Condition: 0.5 A 125 V AC resistive load, 20 cpm
Change of pick-up and drop-out voltage
5.-(2) Coil temperature rise (4C)
Tested sample: TQ4-12V
Measured portion: Inside the coil
Ambient temperature: 30 C
7. Distribution of pick-up and drop-out voltages
Tested sample: TQ2-12V, 50 pcs.
10. Distribution of contact resistance
Tested sample: TQ2-12V, 30 pcs. (30 4 contacts)
100
90
80
70
60
50
40
30
20
10
30
20
10
70
60
50
40
30
20
10
40
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100
0
0
100 110 120 130 140 150
Drop-out voltage
30
Ratio against the rated voltage, %V
Pick-up voltage
Drop-out voltage
Coil applied voltage, %V
Contact resistance, m
No. of operations, 10
40
5
Pick-up voltage
86 F
50
4
1 A
0 A
10
Max.
Min.
Max.
Min.
TQ

Related parts for TQ2-24VDC