JQ112F PANASONIC EW, JQ112F Datasheet - Page 4

RELAY, PCB, SPCO, 12VDC

JQ112F

Manufacturer Part Number
JQ112F
Description
RELAY, PCB, SPCO, 12VDC
Manufacturer
PANASONIC EW
Datasheet

Specifications of JQ112F

Relay Type
General Purpose
Coil Voltage Vdc Nom
12V
Contact Current Max
5A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
360ohm
Coil Type
DC Coil
Coil Current
33.3mA
Nom
RoHS Compliant
Contact Configuration
SPCO
Rohs Compliant
Yes
3-(1). Coil temperature rise (1 Form A type)
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
4-(1). Ambient temperature characteristics
(1 Form A type)
Tested sample: JQ1a-24V
Contact carrying current: 3 A, 5 A
High capacity type
1-(1). Operate & release time (1 Form A type)
Tested sample: JQ1aP-12V, 25 pcs.
3-(1). Coil temperature rise (1 Form A type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
400
300
200
100
50
40
30
20
10
70
60
50
40
30
20
10
0
0
8
6
4
2
0
0
5 A at 85°C
3 A at 85°C
100 110 120 130 140
100
80
20
10 A at 70°C
7
5
30
5 A at 70°C
3 A at 70°C
120
6
100
Coil applied voltage, %V
Coil applied voltage, %V
Coil applied voltage, %V
Ambient temperature, °C
40
5 A at 85°C
Operate time
Release time
140
50
3
120
10 A at 85°C
150
60
160
4
5 A at 70°C
160
70
170
1
80
180
180
150
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Max.
Min.
Max.
Min.
2
190
90
3-(2). Coil temperature rise (1 Form C type)
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
4-(2). Ambient temperature characteristics
(1 Form C type)
Tested sample: JQ1-24V
Contact carrying current: 3 A, 5 A
1-(2). Operate & release time (1 Form C type)
Tested sample: JQ1P-12V, 25 pcs.
3-(2). Coil temperature rise (1 Form C type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
400
300
200
100
70
60
50
40
30
20
10
70
60
50
40
30
20
10
0
8
6
4
2
0
0
0
3 A at 70°C
80
100 110 120 130 140
20
100 110 120 130 140 150 160
10 A at 70°C
3 A at 85°C
30
6
100
1
5
Coil applied voltage, %V
Coil applied voltage, %V
Coil applied voltage, %V
Ambient temperature, °C
5 A at 70°C
40
5 A at 85°C
Operate time
Release time
2
10 A at 85°C
50
5 A at 85°C
7
120
60
5 A at 70°C
3
70
4
150
80
150
Max.
Max.
Min.
Min.
160
90
1 Allowable ambient temperature against
2 Allowable ambient temperature against
3 Allowable ambient temperature against
4 Allowable ambient temperature against
5 Pick-up voltage with a hot-start condition
6 Pick-up voltage with a hot-start condition
7 Pick-up voltage
2. Life curve
Ambient temperature: room temperature
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 3 A)
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 5 A)
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 3 A)
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 5 A)
of 100%V on the coil (Carrying current: 5 A)
of 100%V on the coil (Carrying current: 3 A)
100
10
1
0
250V AC resistive load
2
4
Contact current, A
125V AC resistive load
6
8
JQ
10

Related parts for JQ112F