C3-R20115A RELECO, C3-R20115A Datasheet - Page 7

RELAY, DPCO, 115VAC, LATCHING

C3-R20115A

Manufacturer Part Number
C3-R20115A
Description
RELAY, DPCO, 115VAC, LATCHING
Manufacturer
RELECO
Datasheet

Specifications of C3-R20115A

Relay Type
General Purpose
Coil Voltage Vac Nom
115V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
16ohm
Coil Type
AC Coil
Coil Current
2.5mA
Nom
RoHS Compliant
Contact Configuration
DPCO
Rohs Compliant
Yes
Contacts
Materials
Max. switching current
Peak inrush current (20 ms)
Max. switching voltage, (pollution 3)
Max. switching voltage, (pollution 2)
Max. AC load (Table 1)
Max. DC load
Standard types
AC 24, 48, 115 (110 ... 120), 230
X = LED (optional)
RC suppressor
DC 12, 24, 48, 110, 120/125, 220
X = LED (optional)
Free wheeling diode
Free wheeling and polarity C2-A20F X/ ... V
AC/DC rectifier (60V max.) C2-A20B X/ ... V
Specifications
Nominal coil power: 2,2 VA (AC), 1,3 W (DC)
Operate time
Release time
Isolation: EN60947 pollution 3, Gr C
Dielectric strength, contacts / coil
Dielectric strength, pole / pole
Dimensions (mm)
C2-A20...
10A / 250V AC1
6A / 250V AC15
Two change-over contacts, 10 A
12 14
4
code 0 (standard); options: 8 - 9
11
1
3
22 24
5
21
8
(50/60 Hz and DC)
6
General purpose
0,5A @ 110V DC1
10A @ 30V DC1
C2-A20
C2-A20R X/ ... V
C2-A20
C2-A20D X/ ... V
A2
A1
A2
2
7
(+)
35
See Table 2
2,5 KVA
A1
X/ ... V
X/ ... V
16 ms.
2,5 KV
2,5 KV
250 V
400 V
8 ms.
250V
10 A
30 A
MRC 8 PIN STANDARD/LOW SIGNAL LEVEL/
OPEN CONTACTS
• Lockable test button
• Marking label on relay
• 2 window mechanical flag (not available on C2-G20)
• Colour coded test button
• Coil voltage marked on top of relay
• Label carries full technical information
• CE marked
Contacts
Materials
Switching current:
Peak inrush current (5 ms)
Max. switching voltage, (pollution 3)
Max. switching voltage, (pollution 2)
Max. AC load (Table 3, page 45)
Max. DC load
Standard types
AC 24, 48, 115 (110 ... 120), 230
X = LED (optional)
RC suppressor
DC 12, 24, 48, 110, 120/125, 220
X = LED (optional)
Free wheeling diode
Free wheeling and polarity C2-T21F X/ ... V
AC/DC rectifier (60V max.) C2-T21B X/ ... V
Specifications
Nominal coil power: 2,2 VA (AC), 1,3 W (DC)
Operate time
Release time
Isolation: EN60947 pollution 3, Gr C
Dielectric strength, contacts / coil
Dielectric strength, pole / pole
Table 1
C2-A, C2-G, C3-A, C3-G, C3-R, C5-R
KVA
C2-T21...
Two change-over, bifurcated contacts
6A / 250V AC1
0,1
10
1
0,5
Min.
12
Electrical life (ops x 10
4 3
11
1
14
1
code 1 (standard); option: 2
5mA @ DC 5V
22
5 6
44
21
8
(50/60 Hz and DC)
24
See Table 18, page 51
min. 5 mA;
1,5
C2-T21
C2-T21R X/ ... V
C2-T21
C2-T21D X/ ... V
6A @ 30V DC1
A1 (+)
A2
2
7
2
Low level
AC1
AC15
6
max. 6 A
)
1,2 KVA
X/ ... V
X/ ... V
2,5
16 ms.
2,5 KV
2,5 KV
250 V
400 V
8 ms.
250V
15 A
Contacts
Materials
Max. switching current
Peak inrush current (20 ms)
Max. switching voltage, (pollution 3)
Max. switching voltage, (pollution 2)
V Max. AC load (Table 1)
Max. DC load
Standard types
AC 24, 48, 115 (110 ... 120), 230
X = LED (optional)
RC suppressor
DC 12, 24, 48, 110, 120/125, 220
X = LED (optional)
Free wheeling diode
Free wheeling and polarity C2-G20F X/ ... V
AC/DC rectifier (60V max.) C2-G20B X/ ... V
Specifications
Nominal coil power: 2,4 VA (AC), 1,6 W (DC)
Operate time
Release time
Isolation: EN60947 pollution 3, Gr C
Dielectric strength, contacts / coil
Dielectric strength, pole / pole
Table 2
C2-A, C3-(A, R),C4-(A, R), C5-R, C7-A
C2-G20...
1,2A @ 110V DC1
10A / 250V AC1
gap 1,7 mm
Volts 25
0,1
10
1
1
3
75
General purpose, DC
8
(50/60 Hz and DC)
Two open contacts
6
0,4A @ 220V DC1
0,3A @ 110 V DC13
125
See Table 4, page 45
Max. DC load
code 0 (standard)
C2-G20 X/ ... V
C2-G20R X/ ... V
C2-G20 X/ ... V
C2-G20D X/ ... V
A1 (+)
A2
RELAYS
7
2
175
DC1
DC13
2,5 KVA
20 ms.
10 ms.
2,5 KV
2,5 KV
250 V
250V
225
10 A
30 A
400

Related parts for C3-R20115A