22.21.9.012.4000 FINDER, 22.21.9.012.4000 Datasheet

RELAY, MODULAR, SPNO, 20A, 12VDC

22.21.9.012.4000

Manufacturer Part Number
22.21.9.012.4000
Description
RELAY, MODULAR, SPNO, 20A, 12VDC
Manufacturer
FINDER
Datasheet

Specifications of 22.21.9.012.4000

Relay Type
Modular
Coil Voltage Vdc Nom
12V
Contact Current Max
30A
Contact Voltage Ac Nom
250V
Coil Resistance
460ohm
Coil Type
DC Coil, Monostable
Coil Current
104mA
Nom Operating
RoHS Compliant
Contact Configuration
SPST
Rohs Compliant
Yes
Features
1 or 2 pole, 20 A relay
for direct 35 mm rail (EN 60715) mounting
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated voltage/Maximum switching voltage V AC
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
Rated power AC/DC
Operating range
Technical data
Mechanical life AC/DC
Electrical life at rated load in AC1
Operate/release time
Maximum impulse duration
Insulation between coil and contacts (1.2/50 µs) kV
Ambient temperature range
Protection category
Approvals (according to type)
17.4 mm wide
Test button
Identification label
AC coils and DC coils
35 mm rail (EN 60715) mount
Cadmium free contact material
N
)
V AC (50/60 Hz)
VA (50 Hz)/W
mW (V/mA)
AC (50 Hz)
cycles
cycles
V DC
kW
DC
VA
VA
ms
°C
A
A
Single phase switch 1 NO
35 mm rail (EN 60715) mount
(SPST-NO)
12 - 24 - 48 - 110
1 NO (SPST-NO)
1,000 (10/10)
(0.85…1.1)U
(0.9…1.1)U
20/0.3/0.12
continuous
250/400
500 · 10
–40…+40
AgSnO
50 · 10
8 - 12 - 24 - 48 - 110 - 120 - 230 - 240
3/1.25
22.21
20/30
5,000
1,000
15/8
IP 20
4
22 Series - Modular monostable relays 20 A
2
3
3
N
N
Double phase switch 2 NO
35 mm rail (EN 60715) mount
(DPST-NO)
12 - 24 - 48 - 110
2 NO (DPST-NO)
1,000 (10/10)
(0.85…1.1)U
20/0.3/0.12
(0.9…1.1)U
continuous
–40…+40
500 · 10
250/400
50 · 10
AgSnO
3/1.25
22.22
20/30
5,000
1,000
15/8
IP 20
4
2
3
3
N
N
1

Related parts for 22.21.9.012.4000

22.21.9.012.4000 Summary of contents

Page 1

... Breaking capacity DC1: 30/110/220 V Minimum switching load mW (V/mA) Standard contact material Coil specification Nominal voltage ( (50/60 Hz Rated power AC/DC VA (50 Hz)/W Operating range AC (50 Hz) DC Technical data Mechanical life AC/DC cycles Electrical life at rated load in AC1 cycles Operate/release time Maximum impulse duration Insulation between coil and contacts (1.2/50 µ ...

Page 2

... Breaking capacity DC1: 30/110/220 V Minimum switching load mW (V/mA) Standard contact material Coil specification Nominal voltage ( (50/60 Hz Rated power AC/DC VA (50 Hz)/W Operating range AC (50 Hz) DC Technical data Mechanical life AC/DC cycles Electrical life at rated load in AC1 cycles Operate/release time Maximum impulse duration Insulation between coil and contacts (1.2/50 µ ...

Page 3

... Dielectric strength between supply and contacts V AC 3,500 between open contacts between adjacent contacts Other data Bounce time Power lost to the environment without contact current with rated current Screw torque Max. wire size AWG 1x12 / 2x14 If the coil is operated for a prolonged period of time, adequate ventilation of the relays must be provided - suggested gap between adjacent relays ...

Page 4

... Accessories Adaptor for panel mounting, 17.5 mm wide 020.01 Sheet of marker tags, plastic, 24 tags, 9x17 mm 020. Series - Modular monostable relays 20 A 020.01 020.24 ...