PXL-10.924 BRODERSEN, PXL-10.924 Datasheet - Page 2

RELAY, V/I, THRESHOLD, 24VDC

PXL-10.924

Manufacturer Part Number
PXL-10.924
Description
RELAY, V/I, THRESHOLD, 24VDC
Manufacturer
BRODERSEN
Series
PXLr
Datasheet

Specifications of PXL-10.924

Contact Configuration
SPDT
Power Consumption
2W
Supply Voltage Max
24V
Relay Mounting
DIN Rail
Control Voltage Type
DC
Coil Voltage Vdc Nom
24V
Contact Current Ac Max
8A
TECHNICAL DATA
Input:
Output:
Supply voltage:
AC
General data:
Export:
Tel:
Fax:
E-mail: bc@brodersencontrols.com
Input signal
0-5V DC
0-10V DC
-10-+10V DC
0-20mA DC
4-20mA DC
Selected via switches on the front panel.
Hysteresis:
Response time:
Upper critical frequency 30 Hz.
SPDT relay:
Max load AC:
Max load DC:
Max. in rush
current:
Min. in rush
current:
Frequency :
Life span:
Delay:
Versions:
Net frequency:
Consumption:
Ambient temperature:-20 to 55°C.
Storage temperature:-40 to 80°C.
Mounting:
Terminals:
Indicators:
Protection:
Electric isolation:
Housing:
Terminal block:
Weight:
+45 46 74 00 00
+45 46 75 73 36
Impedance
>100kOhm
>100kOhm
>100kOhm
50 Ohm
50 Ohm
±0,5-20% of range, adjustable.
Time constant ( = approx. 0,3s,
worst case of response time max. 5x ).
Contact material, AgNi 0,15 with hardened
gold plating Au.
8A/240V AC (cos =1)
Max. breaking capacity2000VA.
Inductive load. See fig. 1.
8A/24V DC.
Max. breaking capacity 50-270W. See fig. 2.
15A (max. 4s/duty cycle less than 10%)
10mA, 24V DC.
Max. 1000 operations pr. hour.
Mech. Min. 3 x 10
Elect. Min. 1x 10
<20ms.
924 = 24V DC (20,4-27,6)V DC
115 = 24/115V AC (20,4-27,6/98-132)V AC
230 = 24/230V AC (20,4-27,6/196-264)V
45-65Hz
AC; 3VA
DC; 2W
35mm DIN-rail (EN50022).
Screw terminals with dual compartment.
Terminal screws are combined
crosshead/slotted.
Up to 2 x 2,5mm
inc. ferrule).
Recommended torque, 0,5Nm.,
max. 0,7 Nm. (VDE0609-1).
Terminal identification in accordance with
DIN46199/EN50005.
Red LED = relay switched on.
IP20.
3,75kVAC (1 min.) between input,
supply and relay output (EN60950).
Noryl (GE), UL94V1.
Noryl (GE), UL94V0.
180 g.
Green LED = operating voltage.
United Kingdom:
Tel:
Fax:
E-mail: bcs@brodersen.co.uk
Umax = 50Vp-p
I
MAX
2
5
operations with full load.
wire (2 x 1,5mm
7
+44 020 8546 4283
+44 020 8547 3628
operations.
= 50mA
2
WIRING DIAGRAM
SPECIFICATIONS:
PXL-10 is designed and developed with regard to relevant specifi-
cations:
• EN60204-1 / VDE0113 electrical material on machines.
• VDE0110 / IEC664 Isolation specifications/creepage and clear-
ance
• Electrical safety in accordance with EN61010.
• IEC414 Safety regulations for control and monitoring equipment.
• EMC:
• Humidity in accordance with IEC68-2-3; RH=95%, 40°C.
• Vibration in accordance with IEC68-2-6:
• Shock when mounted, in accordance with IEC68-2-27.
PXL-10 is CE-marked in accordance with EMC-and the Low Voltage
Directive.
OUTPUT LOAD DIAGRAMS
Fig. 1
Fig. 2
U [V]
300
200
100
L(115/230)
50
20
+ (24V)
1,0
0,9
0,8
0,7
0,6
0,5
0,4
Germany:
Tel:
Fax:
E-mail: ba@brodersen.de
0,1
Input
0,2
Y1
A1
A3
16
0,2
L(24V)
+49 208 46954-0
+49 208 46954-50
0
-
16 18
I
15
Y2
15
Z1
18
0,5
IN
+
0,4
µ
V
-(0V)
IN
+
N
Y3
Z2
A2
Z3
1,0
0,6
Inversion
relay
distances.
Emission EN50081-1
Immunity EN50082-2
2,0
AC supply
DC supply
Signal Converters & Isolators
0,8
5,0
Latch
active
Coding:
Relay inverter: Z1-Z2
Latching:
cos
8,0
Threshold Relay PXL-10
1,0
I [A]
Z1-Z3
75

Related parts for PXL-10.924