4C.02.9.012.0050SPA FINDER, 4C.02.9.012.0050SPA Datasheet - Page 4

RELAY MODULE, DPDT, 8A, 12VDC

4C.02.9.012.0050SPA

Manufacturer Part Number
4C.02.9.012.0050SPA
Description
RELAY MODULE, DPDT, 8A, 12VDC
Manufacturer
FINDER
Datasheet

Specifications of 4C.02.9.012.0050SPA

Coil Voltage Vdc Nom
12V
Contact Current Max
15A
Contact Voltage Ac Nom
250V
Coil Resistance
300ohm
Average Power Consumption
500mW
Relay Mounting
DIN Rail
External Width
15.8mm
External
RoHS Compliant
Contact Configuration
DPDT
Rohs Compliant
Yes
Contact specification
F 4C - Electrical life (AC) v contact current
H 4C - Maximum DC1 breaking capacity
Coil specifications
DC coil data
R 4C - DC coil operating range v ambient temperature
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
4
Nominal
voltage
125
U
12
24
U
U
V
N
N
Types 4C.02/52
0.2
0.1
10
10
10
20
10
2.0
1.5
1.0
0.5
6
4
2
1
20
7
6
5
0
-20
9.012
9.024
9.125
Current limit 1 CO (SPDT) (*)
code
Coil
Current limit 2 CO (DPDT)
60
0
2
Operating range
17.5
91.2
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
U
8.8
V
min
20
100
DC voltage (V)
1
2
Temperature limit for the single pole version under full 16 A contact current.
137.5
4
13.2
26.4
U
40
max
V
140
Resistance Rated coil
60
32000
6
Single Pole Relay
Contact Current
limited to 12 A
1200
180
300
R
4C Series - Relay interface modules 8 - 10 - 16 A
(°C)
80
consumption
I at U
220
40
20
mA
3.9
(A)
8
N
F 4C - Electrical life (AC) v contact current
(*) Type 4C.01= 12 A, Type 4C.51= 10 A
• When switching a resistive load (DC1) having voltage and current
• In the case of DC13 loads, the connection of a diode in parallel with
R 4C - AC coil operating range v ambient temperature
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
AC coil data
values under the curve, an electrical life of ≥ 100·10
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
Nominal
voltage
U
U
110
120
230
U
12
24
N
V
Types 4C.01/51
N
10
10
10
2.0
1.5
1.0
0.5
7
6
5
0
-20
8.012
8.024
8.110
8.120
8.230
code
Coil
0
4
1
2
184
Operating range
19.2
88
96
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
U
9.6
V
min
20
8
121
132
253
U
40
13.2
26.4
max
V
Resistance Rated coil
60
12
28000
Single Pole Relay
Contact Current
limited to 12 A
6900
9000
3
320
R
can be expected.
80
(°C)
80
consumption
I at U
90
45
16
(A)
mA
9.4
8.4
5
N

Related parts for 4C.02.9.012.0050SPA