LC1D18R7 SQUARE D, LC1D18R7 Datasheet - Page 231

IEC Contactor

LC1D18R7

Manufacturer Part Number
LC1D18R7
Description
IEC Contactor
Manufacturer
SQUARE D
Datasheet

Specifications of LC1D18R7

No. Of Poles
3
Contact Configuration
3PST-NO
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
440V
Relay Terminals
Screw Clamp
Width
45mm
Coil Resistance
2.24kohm
Nom Operating Power
10kW
External Width
45mm
Operating Voltage
600VAC
Switching Power Ac1
3hp
Switching Power Ac3
15hp
Switching Current Ac1
32A
Switching Current Ac3
18A
Load Current Inductive
18A
Load Current Resistive
32A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
01/04
LA1DN22
LA DT, DS
LA9F103
DZ2F
EZ2LB0601
Magnetic Latching Contactors - Accessories - Selection
For Contactors CR1F
Lug Kits
Lugs can be ordered either individually (for 2- and 4-pole contactors) or in sets of 6 (for 3-pole
contactors). Mounting hardware is provided with the contactors, not the kits.
For Contactors CR1B
Coil Selection
Description
Instantaneous auxiliary
contacts
Time delay auxiliary
contacts
Insulated Terminal Blocks
provides IP20 touch-safe
protection
c
Single lug
DZ2FF1
DZ2FG1
DZ2FH1
DZ3FJ1
DZ2FK1
DZ2FL f
DZF2FX
q
f
Description
Mechanical interlock and power connections
Description
Mechanical interlock with
mounting accessories p
Kit containing 2 bar mounting brackets
p
Volts
For contactors CR1F
AC 50/60 Hz
AC 400 Hz
DC
DC low consumption
For contactors CR1B
AC 50 to 400 Hz
DC
For selection, see pages 194 through 197.
When direct mounting the LR9F to an LC1F or CR1F contactor, lugs of different sizes may be required. See page 220 for additional information.
For 3-pole F630 contactors, order DZ2FL1 for L1 and T3, DZ2FL2 for L2 and T2 and DZ2PL3 for L3 and T1 terminals.
For 4-pole F6304 contactors, order DZ2FL1 for L1 and T4, DZ2FL2 for L2, T2, L3 and T3 and DZ2FL3 for L4 and T1 terminals.
Positive mechanical interlocking between two vertically-mounted contactors with identical or different ratings. Connecting rods and cranks
assembled on right-hand side, crank pins on the pole side. Vertical mounting center distance between the two contactors: 600 mm (23.62").
48
E7
E7
E7
EZ7
Set of six lugs
DZ2FF6
DZ2FG6
DZ2FH6
DZ3FJ6
DZ2FK6
DZ2FL6
DZ2FX6
Number of contacts
or shrouds
1 to 9
2 to 4
Set of 2 blocks
110
F7
F7
F7
FZ7
F
FD
Magnetic Latching Contactors – Accessories – Selection
125
GD
Application
For vertical assembly of reversing contactors
and changeover contactor pairs
For mounting on 120 or 150 mm center
(4.72" or 5.91")
Application
For assembly of reversing contactors and
changeover contactor pairs
14 to 2/0
6 to 300 MCM
2 x 2 to 600 MCM
3 x 2 to 600 MCM
4 x 1/0 to 750 MCM
Cable size AWG range
6 to 3/0
4 to 500 MCM
127
G7
G7
G7
GZ7
G
For use on
CR1F
CR1F
CR1F150 and CR1F185
AWG cable size #6 to 300mcm
220
M7
M7
M7
MZ7
M
MD
230
M7
M7
M7
M
©
240
U7
U
UD
2001-2004 Schneider Electric All Rights Reserved
F115
F265, F330
F780
Suitable for contactor
LC1
F150, F185
F400
F500
F630, F800
Catalog Number
LA1D c
LA D c
LA9F103
250
VcD
/CR1
Catalog number
EZ2LB0601
LA9B103
Catalog Number
See pages 190 to 193.
380
Q7
Q
400
Q7
V
Suitable for overload relay
LR9
none
F5 57, F5 63, F5 67, F5 69
LR9F 71
none
F7 75, F7 79
F7 81
none
Weight lb (kg)
1.27 (0.580)
1.27 (0.580)
0.66 (0.300)
415
N7
N
Weight lb (kg)
3.44 (1.560)
3.57 (1.620)
q
R
440
RD
500
S
SD
231

Related parts for LC1D18R7