C30CNE20A0 EATON CUTLER HAMMER, C30CNE20A0 Datasheet - Page 34

Lighting Contactor

C30CNE20A0

Manufacturer Part Number
C30CNE20A0
Description
Lighting Contactor
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of C30CNE20A0

No. Of Poles
2
Contact Configuration
DPST-NC
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
120V
Contact Current Max
30A
Mounting Type
DIN Rail
External Height
187.6mm
Continuous Load Current
30A
Operating Voltage
600VAC
Switching Current Ac1
30A
Switching Current Ac3
30A
Load Current Inductive
30A
Contactor Direction
Reversing
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
37
37-34
Table 37-54. C — Control Power Transformer, IT. Power Supplies,
Control Relays, Cover Control (not elsewhere defined), Current
Transformers, Compelling Relay, Control Wiring, Control Circuit Breaker,
Separate Control, Customer-Supplied Components, Custom for
Advantage, Contactors, Counter, E-Stop Relay, DC/AC Interface,
Separate Source Disconnect, Bypass Contactors
Modification
Control Power
Transformers
Make sure
8th character
specifies
primary/
secondary
voltage.
Power Supplies
(IT. and XT
Only)
Control Relays C12
Cover Control
Not available for IT. Starters.
Not available for XT Starters.
Lighting Contactors
UL Rated AC Contactors
Modification Codes
Catalog
Number
Suffix
C1
C2
C42
C3
C4
C5
C6
C7
C8
C9
C10
C11
C34
C27
C28
C13
C14
C15
C16
C18
C20
C17
C19
C29
Description
Standard Size Control Transformer,
120V/60 Hz, 110V/50 Hz Secondary with
2 Primary and 1 Secondary Fuse
Standard Size Control Transformer,
24V/60 Hz Secondary with 2 Primary and
1 Secondary Fuse
50 VA Extra Capacity CPT 120V/60 Hz,
110V/50 Hz with 2 Primary and
1 Secondary
100 VA Extra Capacity CPT, 120V/60 Hz,
110V/50 Hz Secondary with
2 Primary and 1 Secondary Fuse
100 VA Extra Capacity CPT, 24V/60 Hz
Secondary with 2 Primary and
1 Secondary Fuse
200 VA Extra Capacity CPT, 120V/60 Hz,
110V/50 Hz Secondary with 2 Primary and
1 Secondary Fuse
200 VA Extra Capacity CPT, 24V/60 Hz
Secondary with 2 Primary and
1 Secondary Fuse
300 VA Extra Capacity CPT, 120V/60 Hz,
110V/50 Hz Secondary with 2 Primary and
1 Secondary Fuse
400 VA Extra Capacity CPT, 120V/60 Hz,
110V/50 Hz Secondary with 2 Primary and
1 Secondary Fuse
1 kVA Extra Capacity CPT, 120V/60 Hz,
110V/50 Hz Secondary with 2 Primary and
1 Secondary Fuse
2 kVA Extra Capacity CPT, 120V/60 Hz,
110V/50 Hz Secondary with 2 Primary and
1 Secondary Fuse
Control Transformer — Order by Description
CPT with Power Supply for IT. or XT
Separate Control 120V AC to 24V DC
Power Supply with Extra Capacity — Order
by Description
4-Pole Interposing Relay, 600V (2NO/2NC)
Run Relay, 24V DC (MVX)
4-Pole, Unwired, A600 Rtg. — 2NO-2NC
8-Pole, Unwired, A600 Rtg. — 4NO-4NC
Control Relay — Order by Description
3-Wire Control Module (C30 Lighting)
2-Wire Control Relay for Mechanical/
Magnetic Lighting Contactors
Convert Position 7 to E30 Type
Cover Control
Lock-Off Attachment Added on
Cover Control
Change to E22 (22 mm) Cover Controls
For more information visit: www.eaton.com
Table 37-54. C — Control Power Transformer, IT. Power Supplies,
Control Relays, Cover Control (not elsewhere defined), Current
Transformers, Compelling Relay, Control Wiring, Control Circuit Breaker,
Separate Control, Customer-Supplied Components, Custom for
Advantage, Contactors, Counter, E-Stop Relay, DC/AC Interface,
Separate Source Disconnect, Bypass Contactors (Continued)
Modification
Current
Transformer(s)
Compelling
Relay
Control
Wiring
Control
Circuit
Breaker
Separate
Control
Customer
Supplied
Components
Custom for
Advantage
Contactor/
Starter
Counter
E-Stop Relay
DC/AC
Interface
Separate
Source
Disconnect
Bypass
Contactors
for IT./MVX
Starters
(MVX: 1/2 to
5 hp Only)
Not available for IT. Starters.
Includes CPT, Pilot Lights, Selector Switch, Auxiliary Contacts and
Control Relay.
Not available for XT Starters.
Number
Suffix
C21
C22
C23
C25
C26
C30
C31
C33
C32
C35
C36
C37
C39
C40
C41
C43
C44
C45
C46/J1
C46/J2
C46/J3
C46/J4
C46/J5
Catalog
Description
In Phase 1
In Phases 1 and 2
In 3 Phases
Omit Control Wiring
With Separate Control Wiring and Two
250V Fuses in Holder
With Common Control Wiring and Two
600V (Class C) Fuses in Holder
Control Wiring Type — Order by Description
Order by Description
Wired for Separate Control
(Reduced Voltage)
Customer Supplied Components to
Be Installed
Customer Supplied Wiring Diagram to Use
Advantage+ Starter Supplied
Contactor/Starter — Order by
Description
Operations Counter
E-Stop Relay (DeviceNet)
DC/AC Interface Module
IEC Separate Source Disconnect for
Control Circuitry
Isolation Contactor
Output Contactor
Bypass Contactor
Isolation/Output/Bypass Contactor
3-Contactor Bypass Pkg. for MVX
CA08102001E
June 2008

Related parts for C30CNE20A0