LC1D09BD SQUARE D, LC1D09BD Datasheet - Page 42

no-image

LC1D09BD

Manufacturer Part Number
LC1D09BD
Description
CONTACTOR, 3PST-NO, 24VDC, 20A, DIN RAIL
Manufacturer
SQUARE D
Datasheet

Specifications of LC1D09BD

No. Of Poles
3
Contact Configuration
3PST-NO
Relay Mounting
DIN Rail
Coil Voltage Vdc Nom
24V
Width
45mm
Relay Terminals
Screw Clamp
Contact Voltage Ac Max
600V
Operating Voltage
600VAC
Switching Power Ac1
1hp
Switching Power Ac3
7.5hp
Switching Current Ac1
25A
Switching Current Ac3
9A
Load Current Inductive
9A
Load Current Resistive
25A
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Characteristics of Type LC•K and LP•K Contactors
42
©
2001-2004 Schneider Electric All Rights Reserved
Auxiliary Contact Characteristics and Instantaneous Contact Blocks
Number of contacts
Rated operational voltage (Ve)
Rated insulation voltage (Vi)
Conventional thermal current (lth)
Frequency of operational current
Minimum switching capacity
Short-circuit protection
Rated making capacity
Overload current
Insulation resistance
Non-overlap distance
Operational power of contacts
conforming to IEC 60947
1 million operating cycles
2 million operating cycles
10 million operating cycles
Occasional making capacity
1
maximum of 50 operating cycles at 10 s
intervals (breaking current = making
current x power factor 0.7).
2
3
maximum of 20 operating cycles at 10 s
intervals with current passing for 0.5 s
per operating cycle.
4
Breaking limit of contacts valid for
Electrical durability of contacts for:
- 1 million operating cycles (2a)
- 3 million operating cycles (2b)
-10 million operating cycles (2c).
Breaking limit of contacts valid for
Thermal limit.
16 000
10 000
On LC K or LP K
On LA1K
Up to
Conforming to BS 5424
Conforming to IEC 60947
Conforming to VDE 0110 group C
Conforming to CSA C 22.2 No.14, UL 508
For ambient temperature
V min (DIN 19 240)
I min
Conforming to IEC 60947 and VDE 0660, gl fuse
Conforming to IEC 60947
Permissible for
Linked contacts conforming to INRS and BIA spec.
AC supply, category AC-15
Electrical durability (valid up to 3600 operating cycles
per hour) on an inductive load such as the coil of an
electromagnet: making current (power factor 0.7) = 10
times the breaking current (power factor 0.4).
V
VA
VA
VA
VA
Power in broken VA
8000
6000
5000
4000
3000
2000
1000
600
500
400
300
200
100
800
80
60
40
24
24
48
17
7
1000
48
48
96
34
14
2050
2a
2b
1
4
110
110/
127
240
86
36
5000
120
50 °C (122 °F)
2c
220
220/
230
440
158
66
10000 13000 9000
380 500
440 690 V
I rms
1 s
500 ms
100 ms
440
880
317
132
600/
690
1200
500
200
250
200
140
100
1
2 or 4
690 Vac
690 Vac
690 Vac
750 Vac
600 Vac
10 A
Up to 400 Hz
17 Vac
5 mA
10 A
110 A
80 A
90 A
110 A
> 10 m
0.5 mm
DC supply, category DC-13
Electrical durability (valid up to 1200 operating cycles
per hour, on an inductive load such as the coil of an
electromagnet, without economy resistor, the time
constant increasing with the load.
V
W
W
W
W
Power in broken W
50
20
1000
100
700
500
300
200
80
60
50
40
30
20
10
8
6
24
120
55
15
720
12
24
48
80
38
11
600
48
110
60
30
9
400
4
3
2b
2a
2c
110
220
52
28
8
300
220
440
51
26
7
230
440 600 V
600
50
25
6
200
01/04

Related parts for LC1D09BD